Curcumin-releasing mechanically adaptive intracortical implants improve the proximal neuronal density and blood–brain barrier stability
Tài liệu tham khảo
Nicolelis, 2003, Brain-machine interfaces to restore motor function and probe neural circuits, Nat Rev Neurosci, 4, 417, 10.1038/nrn1105
Schwartz, 2004, Cortical neural prosthetics, Annu Rev Neurosci, 27, 487, 10.1146/annurev.neuro.27.070203.144233
Taylor, 2002, Direct cortical control of 3D neuroprosthetic devices, Science, 296, 1829, 10.1126/science.1070291
Chestek, 2011, Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex, J Neural Eng, 8, 045005, 10.1088/1741-2560/8/4/045005
McConnell, 2009, Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration, J Neural Eng, 6, 056003, 10.1088/1741-2560/6/5/056003
Biran, 2005, Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays, Exp Neurol, 195, 115, 10.1016/j.expneurol.2005.04.020
Potter, 2012, Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses, J Neural Eng, 9, 046020, 10.1088/1741-2560/9/4/046020
Harris, 2011, Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies, J Neural Eng, 8, 066011, 10.1088/1741-2560/8/6/066011
Winslow, 2010, A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex, Biomaterials, 31, 9163, 10.1016/j.biomaterials.2010.05.050
Potter, 2013, The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes, Biomaterials, 34, 7001, 10.1016/j.biomaterials.2013.05.035
Buzsaki, 2004, Large-scale recording of neuronal ensembles, Nat Neurosci, 7, 446, 10.1038/nn1233
Tresco, 2011, The challenge of integrating devices into the central nervous system, Crit Rev Biomed Eng, 39, 29, 10.1615/CritRevBiomedEng.v39.i1.30
Saxena, 2013, The impact of chronic blood–brain barrier breach on intracortical electrode function, Biomaterials, 34, 4703, 10.1016/j.biomaterials.2013.03.007
He W, Bellamkonda RV, A molecular perspective on understanding and modulating the performance of chronic central nervous system (CNS) recording electrodes, in: Reichert WM, editor. Indwelling neural implants: strategies for contending with the in vivo environment; 2008 [chapter 6].
Skousen, 2011, Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays, Prog Brain Res, 194C, 167, 10.1016/B978-0-444-53815-4.00009-1
Ware, 2012, Fabrication of responsive. Softening neural interfaces, Adv Funct Mater, 22, 3470, 10.1002/adfm.201200200
Capadona, 2012, Mechanically adaptive nanocomposites for neural interfacing, MRS Bull, 37, 581, 10.1557/mrs.2012.97
Tien, 2013, Silk as a multifunctional biomaterial substrate for reduced glial scarring around brain-penetrating electrodes, Adv Funct Mater, 23, 3185, 10.1002/adfm.201203716
Shanmuganathan, 2010, Biomimetic mechanically adaptive nanocomposites, Prog Polym Sci, 35, 212, 10.1016/j.progpolymsci.2009.10.005
Hess, 2013, Environmentally-controlled microtensile testing of mechanically-adaptive polymer nanocomposites for ex vivo characterization, J Vis Exp, 78, e50078
Capadona, 2008, Stimuli-responsive polymer nanocomposites inspired by the sea cucumber dermis, Science, 319, 1370, 10.1126/science.1153307
Capadona, 2007, A versatile approach for the processing of polymer nanocomposites with self-assembled nanofibre templates, Nat Nanotechnol, 2, 765, 10.1038/nnano.2007.379
Jorfi, 2013, Physiologically responsive, mechanically adaptive bio-nanocomposites for biomedical applications, ACS Appl Mater Interfaces, 5, 1517, 10.1021/am303160j
Fox, 2013, Bioinspired water-enhanced mechanical gradient nanocomposite films that mimic the architecture and properties of the squid beak, J Am Chem Soc, 135, 5167, 10.1021/ja4002713
Hess, 2011, Development of a stimuli-responsive polymer nanocomposite toward biologically optimized. MEMS-based neural probes, J Micromech Microeng, 21, 054009, 10.1088/0960-1317/21/5/054009
Ware, 2013, Smart polymers for neural interfaces, Polym Rev, 53, 108, 10.1080/15583724.2012.751924
Favier, 1995, Polymer nanocomposites reinforced by cellulose whiskers, Macromolecules, 28, 6365, 10.1021/ma00122a053
Available from: http://www.alzet.com/products/cfs_prep.php [Accessed 08/04/2009].
Zou, 2004, Antioxidant activity of a flavonoid-rich extract of Hypericum perforatum L. in Vitro, J Agric Food Chem, 52, 5032, 10.1021/jf049571r
Potter, 2012, Reduction of autofluorescence at the microelectrode-cortical tissue interface improves antibody detection, J Neurosci Methods, 203, 96, 10.1016/j.jneumeth.2011.09.024
Ravikumar, 2012, An organotypic spinal cord slice culture model to quantify neurodegeneration, J Neurosci Methods, 211, 280, 10.1016/j.jneumeth.2012.09.004
Winslow, 2010, Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex, Biomaterials, 31, 1558, 10.1016/j.biomaterials.2009.11.049
Azemi, 2011, The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interface, Biomaterials, 32, 681, 10.1016/j.biomaterials.2010.09.033
Mullen, 1992, NeuN, a neuronal specific nuclear protein in vertebrates, Development, 116, 201, 10.1242/dev.116.1.201
Cole, 2011, Craniotomy: true sham for traumatic brain injury, or a sham of a sham?, J Neurotrauma, 28, 359, 10.1089/neu.2010.1427
Eddleston, 1993, Molecular profile of reactive astrocytes–implications for their role in neurologic disease, Neuroscience, 54, 15, 10.1016/0306-4522(93)90380-X
Aschner, 2002, Astrocyte modulation of neurotoxic injury, Brain Pathol, 12, 475, 10.1111/j.1750-3639.2002.tb00465.x
McConnell, 2007, Extraction force and cortical tissue reaction of silicon microelectrode arrays implanted in the rat brain, IEEE Trans Biomed Eng, 54, 1097, 10.1109/TBME.2007.895373
Schmidt, 1976, Long-term chronic recording from cortical neurons, Exp Neurol, 52, 496, 10.1016/0014-4886(76)90220-X
Williams, 2007, Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants, J Neural Eng, 4, 410, 10.1088/1741-2560/4/4/007
Kreutzberg, 1996, Microglia: A sensor for pathological events in the CNS, Trends Neurosci, 19, 312, 10.1016/0166-2236(96)10049-7
Arroyo, 2011, Toll-like receptors are key players in neurodegeneration, Int Immunopharmacol, 11, 1415, 10.1016/j.intimp.2011.05.006
Ito, 1998, Microglia-specific localisation of a novel calcium binding protein, Iba1, Mol Brain Res, 57, 1, 10.1016/S0169-328X(98)00040-0
Dijkstra, 1985, The heterogeneity of mononuclear phagocytes in lymphoid organs: distinct macrophage subpopulations in the rat recognized by monoclonal antibodies ED1, ED2 and ED3, Immunology, 54, 589
Yang, 2005, The cytokine activity of HMGB1, J Leukoc Biol, 78, 1, 10.1189/jlb.1104648
Zhang, 2012, Role of high mobility group box 1 (HMGB1) in wound healing, J Surg Res, 176, 343, 10.1016/j.jss.2011.06.069
Barrese, 2013, Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates, J Neural Eng, 10, 066014, 10.1088/1741-2560/10/6/066014
Prasad, 2012, Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants, J Neural Eng, 9, 056015, 10.1088/1741-2560/9/5/056015
Ward, 2009, Irazoqui PP. Toward a comparison of microelectrodes for acute and chronic recordings, Brain Res, 1282, 183, 10.1016/j.brainres.2009.05.052
Potter KA, Buck AC, Self WK, Capadona JR. Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses. J Neural Eng 2012;9.
Biran, 2005, Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays, Exp Neurol, 195, 115, 10.1016/j.expneurol.2005.04.020
Biran, 2007, The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull, J Biomed Mater Res Part A, 82A, 169, 10.1002/jbm.a.31138
Simeral, 2011, Neural control of cursor trajectory and click by a human with tetraplegia 1000days after implant of an intracortical microelectrode array, J Neural Eng, 8, 025027, 10.1088/1741-2560/8/2/025027
Vetter, 2004, Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex, IEEE Trans Biomed Eng, 51, 896, 10.1109/TBME.2004.826680
Kipke, 2003, Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex, IEEE Trans Neural Syst Rehabil Eng, 11, 151, 10.1109/TNSRE.2003.814443
Suner, 2005, Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex, IEEE Trans Rehabil Eng, 13, 524
Schwartz, 2006, Brain-controlled interfaces: movement restoration with neural prosthetics, Neuron, 52, 205, 10.1016/j.neuron.2006.09.019
Karumbaiah L, Saxena T, Carlson D, Patil K, Patkar R, Gaupp EA, et al. Relationship between intracortical electrode design and chronic recording function. Biomaterials; 2013.
Harris, 2011, In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes, J Neural Eng, 8, 040610, 10.1088/1741-2560/8/4/046010
Way, 2012, PH-responsive cellulose nanocrystal gels and nanocomposites, ACS Macro Lett, 1, 1001, 10.1021/mz3003006
Mendez, 2011, Bioinspired mechanically adaptive polymer nanocomposites with water-activated shape-memory effect, Macromolecules, 44, 6827, 10.1021/ma201502k
Nectow, 2012, Biomaterials for the development of peripheral nerve guidance conduits, Tissue Eng Part B-Re, 18, 40, 10.1089/ten.teb.2011.0240
Pari, 2008, Role of curcumin in health and disease, Arch Physiol Biochem, 114, 127, 10.1080/13813450802033958
Menon, 2007, Antioxidant and anti-inflammatory properties of curcumin, 105
Lao CD, Ruffin MTt, Normolle D, Heath DD, Murray SI, Bailey JM, et al. Dose escalation of a curcuminoid formulation. BMC Complement Altern Med 2006;6:10.
Cheng, 2001, Phase I clinical trial of curcumin, a chemopreventive agent, in patients with high-risk or pre-malignant lesions, Anticancer Res, 21, 2895
Brazel, 2000, Modeling of drug release from swellable polymers, Eur J Pharm Biopharm, 49, 47, 10.1016/S0939-6411(99)00058-2
Wan, 1992, Drug release from heat-treated polyvinyl alcohol films, Drug Dev Ind Pharm, 18, 1895, 10.3109/03639049209046338
Mallapragada, 1997, Crystal dissolution-controlled release systems 1. Physical characteristics and modeling analysis, J Controlled Release, 45, 87, 10.1016/S0168-3659(96)01549-0
Chan, 2003, Curcumin inhibits UV irradiation-induced oxidative stress and apoptotic biochemical changes in human epidermoid carcinoma A431 cells, J Cell Biochem, 90, 327, 10.1002/jcb.10638
Tu, 2012, Protective effects of curcumin against hepatic fibrosis induced by carbon tetrachloride: modulation of high-mobility group box 1, Toll-like receptor 4 and 2 expression, Food Chem Toxicol Int J Published Br Ind Biol Res Assoc, 50, 3343, 10.1016/j.fct.2012.05.050
Gutowski SM, Templeman KL, South AB, Gaulding JC, Shoemaker JT, LaPlaca MC, et al. Host response to microgel coatings on neural electrodes implanted in the brain. J Biomed Mater Res Part A; 2013:DOI: 10.1002/jbm.a.34799.
Skousen J, Bolick K, Bridge M, Tresco P. A predictive model of the foreign body response to devices implanted chronically in the central nervous system. IFESS; 2012.
Ravikumar M, Hageman DJ, Tomaszewski WH, Chandra GM, Skousen JL, Capadona JR. The effect of residual bacterial contamination on the neuroinflammatory response to sterilized intracortical microelectrodes. Biomaterials 2013;Under Review.
Sofroniew, 2009, Molecular dissection of reactive astrogliosis and glial scar formation, Trends Neurosci, 32, 638, 10.1016/j.tins.2009.08.002
Tu, 2012, Protective effects of curcumin against hepatic fibrosis induced by carbon tetrachloride: Modulation of high-mobility group box 1, Toll-like receptor 4 and 2 expression, Food Chem Toxicol, 50, 3343, 10.1016/j.fct.2012.05.050
O’Callaghan, 2008, Defining neuroinflammation, Ann N Y Acad Sci, 1139, 318, 10.1196/annals.1432.032
Frank-Cannon, 2009, Does neuroinflammation fan the flame in neurodegenerative diseases?, Mol Neurodegener, 4, 47, 10.1186/1750-1326-4-47
Rennaker, 2007, Minocycline increases quality and longevity of chronic neural recordings, J Neural Eng, 4, L1, 10.1088/1741-2560/4/2/L01
Ates, 2007, Neuroprotection by resveratrol against traumatic brain injury in rats, Mol Cell Biochem, 294, 137, 10.1007/s11010-006-9253-0
Liu, 2011, Resveratrol improves neuron protection and functional recovery in rat model of spinal cord injury, Brain Res, 1374, 100, 10.1016/j.brainres.2010.11.061
Ware T, Simon D, Hearon K, Kang TH, Maitland DJ, Voit W. Thiol-click chemistries for responsive neural interfaces. Macromol Biosci 2013.
Biswas, 2003, Plant medicines of Indian origin for wound healing activity: a review, Int J Low Extrem Wounds, 2, 25, 10.1177/1534734603002001006