Application of finite element analysis in implant dentistry: A review of the literature

Journal of Prosthetic Dentistry - Tập 85 - Trang 585-598 - 2001
Jian-Ping Geng1, Keson B.C. Tan1, Gui-Rong Liu1
1Faculty of Dentistry and Faculty of Engineering, National University of Singapore, Singapore

Tài liệu tham khảo

Weinstein, 1976, Stress analysis of porous rooted dental implants, J Dent Res, 55, 772, 10.1177/00220345760550051001 Atmaram, 1983, Stress analysis of single-tooth implants. I. Effect of elastic parameters and geometry of implant, Implantologist, 3, 24 Atmaram, 1983, Stress analysis of single-tooth implants. II. Effect of implant root-length variation and pseudo periodontal ligament incorporation, Implantologist, 3, 58 Mohammed, 1979, Dental implant design: a critical review, J Oral Implantol, 8, 393 Borchers, 1983, Three-dimensional stress distribution around a dental implant at different stages of interface development, J Dent Res, 62, 155, 10.1177/00220345830620021401 Cook, 1982, A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant, J Dent Res, 61, 25, 10.1177/00220345820610010501 Meroueh, 1987, Finite element analysis of partially edentulous mandible rehabilitated with an osteointegrated cylindrical implant, J Oral Implantol, 13, 215 Williams, 1990, Finite element analysis of fixed prostheses attached to osseointegrated implants, Quintessence Int, 21, 563 Akpinar, 1996, A comparison of stress and strain distribution characteristics of two different rigid implant designs for distal-extension fixed prostheses, Quintessence Int, 27, 11 Korioth, 1997, Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis, Crit Rev Oral Biol Med, 8, 90, 10.1177/10454411970080010501 Van Oosterwyck, 1998, The influence of bone mechanical properties and implant fixation upon bone loading around oral implants, Clin Oral Implants Res, 9, 407, 10.1034/j.1600-0501.1996.090606.x Rieger, 1990, Finite element analysis of six endosseous implants, J Prosthet Dent, 63, 671, 10.1016/0022-3913(90)90325-7 Rieger, 1990, Finite element survey of eleven endosseous implants, J Prosthet Dent, 63, 457, 10.1016/0022-3913(90)90238-8 Meijer, 1995, The influence of a flexible coating on the bone stress around dental implants, J Oral Rehabil, 22, 105, 10.1111/j.1365-2842.1995.tb00243.x Sertgöz, 1997, Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis, Int J Prosthodont, 10, 19 Keyak, 1990, Automated three-dimensional finite element modeling of bone: a new method, J Biomed Eng, 12, 389, 10.1016/0141-5425(90)90022-F Cahoon, 1994, Interactive modeling environment for craniofacial reconstruction. Visual data exploration and analysis, SPIE Proc, 2178, 206, 10.1117/12.172072 Davy, 1981, Determination of stress patterns in root-filled teeth incorporating various dowel designs, J Dent Res, 60, 1303, 10.1177/00220345810600070301 Wright, 1979, Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments, J Prosthet Dent, 42, 411, 10.1016/0022-3913(79)90142-2 Farah, 1975, Effects of cement bases on the stresses in amalgam restorations, J Dent Res, 54, 10, 10.1177/00220345750540010101 Farah, 1989, Finite element analysis of three- and four-unit bridges, J Oral Rehabil, 16, 603, 10.1111/j.1365-2842.1989.tb01384.x Reinhardt, 1984, Periodontal ligament stresses in the initiation of occlusal traumatism, J Periodontal Res, 19, 238, 10.1111/j.1600-0765.1984.tb00815.x MacGregor, 1980, Stress analysis of mandibular partial dentures with bounded and free-end saddles, J Dent, 8, 27, 10.1016/S0300-5712(80)80042-X Atmaram, 1981, Estimation of physiologic stresses with a nature tooth considering fibrous PDL structure, J Dent Res, 60, 873, 10.1177/00220345810600050301 Rice, 1988, On the dependence of the elasticity and strength of cancellous bone on apparent density, J Biomech, 21, 155, 10.1016/0021-9290(88)90008-5 Cook, 1982, A model for the implant-bone interface characteristics of porous dental implants, J Dent Res, 61, 1006, 10.1177/00220345820610080201 Cowin, 1989 Knoell, 1977, A mathematical model of an in vitro human mandible, J Biomech, 10, 159, 10.1016/0021-9290(77)90054-9 Maeda, 1989, Finite element method simulation of bone resorption beneath a complete denture, J Dent Res, 68, 1370, 10.1177/00220345890680091601 Sakaguichi, 1995, Nonlinear contact analysis of preload in dental implant screws, Int J Oral Maxillofac Implants, 10, 295 Colling, 1984 Lewinstein, 1995, Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis, Int J Oral Maxillofac Implants, 10, 355 Craig, 1989, Restorative dental materials, 84 Lewis, 1994, Aparametric finite element analysis study of the stresses in an endosseous implant, Biomed Mater Eng, 4, 495 Lotz, 1991, Mechanical properties of metaphysical bone in the proximal femur, J Biomech, 24, 317, 10.1016/0021-9290(91)90350-V Cowin, 1988, Strain assessment by bone cells, Tissue Eng, 181 Patra, 1998, Guidelines for analysis and redesign of dental implants, Implant Dent, 7, 355, 10.1097/00008505-199807040-00015 Zhou, 1999, The boundary design of mandibular model by means of the three-dimensional finite element method, West China J Stomatol, 17, 1 Teixeira, 1998, A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics, J Oral Rehabil, 25, 299, 10.1111/j.1365-2842.1998.00244.x Sato, 1999, The effectiveness of a new algorithm on a three-dimensional finite element model construction of bone trabeculae in implant biomechanics, J Oral REhabil, 26, 640, 10.1046/j.1365-2842.1999.00442.x Pilliar, 1991, Dental implant design—effect on bone remodeling, J Biomed Mater Res, 25, 467, 10.1002/jbm.820250405 Vaillancourt, 1996, Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis, Int J Oral Maxillofac Implants, 11, 351 Hassler, 1977, Quantitation of compressive stress and its effects on bone remodeling [proceedings], Bull Hosp Bone Joint Dis, 38, 90 Skalak, 1983, Biomechanical considerations in osseointegrated prostheses, J Prosthet Dent, 49, 843, 10.1016/0022-3913(83)90361-X Ma Xuanxiang, 1998, Single implant prosthesis, 1 Clift, 1992, Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus, Proc Inst Mech Eng [H], 206, 233, 10.1243/PIME_PROC_1992_206_295_02 Geng, 1999, Exceptional prosthodontics, 60 Holmgren, 1998, Evaluating parameters of osseointegrated dental implants using finite element analysis—a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction, J Oral Implantol, 24, 80, 10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO;2 Barbier, 1998, Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog, J Oral Rehabil, 25, 847, 10.1046/j.1365-2842.1998.00318.x Zhang, 1998, The study of effects of changes of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis, West China J Stomatol, 16, 274 Benzing, 1995, Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae, Int J Oral Maxillofac Implants, 10, 188 Stegaroiu, 1998, Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis, Int J Oral Maxillofac Implants, 13, 781 Hobkirk, 1992, The influence of occlusal surface material on peak masticatory forces using ossointegrated implant-supported prostheses, Int J Oral Maxillofac Implants, 7, 345 Cibirka, 1992, Determining the force absorption on quotient for restorative materials used in implant occlusal surfaces, J Prosthet Dent, 67, 361, 10.1016/0022-3913(92)90247-8 Mailath, 1989, Bone resorption at the entry of osseointegrated implants—a biomechanical phenomenon. Finite element study [in German], Z Stomatol, 86, 207 Rieger, 1989, Bone stress distribution for three endosseous implants, J Prosthet Dent, 61, 223, 10.1016/0022-3913(89)90379-X Stoiber, 1988, Biomechanical principles of endosseous screw implants [in German], Wien Klin Wochenschr, 100, 522 Matsushita, 1990, Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution, J Oral Implantol, 16, 611 Lum, 1991, A biomechanical rationale for the use of short implants, J Oral Implantol, 17, 126 Stellingsma, 2000, Use of short endosseous implants and an overdenture in the extremely resorbed mandible: a five-year retrospective study, J Oral Maxillofac Surg, 58, 382, 10.1016/S0278-2391(00)90917-0 Siegele, 1989, Numerical investigations of the influence of implant shape on stress distribution in the jaw bone, Int J Oral Maxillofac Implants, 4, 333 Clift, 1995, Comparative analysis of bone stresses and strains in the Intoss dental implant with and without a flexible internal post, Proc Inst Mech Eng [H], 209, 139, 10.1243/PIME_PROC_1995_209_336_02 Oonishi, 1990, Mechanical and chemical bonding of artificial joints, Clin Mater, 5, 217, 10.1016/0267-6605(90)90021-M Meijer, 1995, The influence of a flexible coating on the bone stress around dental implants, J Oral Rehabil, 22, 105, 10.1111/j.1365-2842.1995.tb00243.x Vaillancourt, 1995, Finite element analysis of crestal bone loss around porous-coated dental implants, J Appl Biomater, 6, 267, 10.1002/jab.770060408 Vaillancourt, 1996, Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis, Int J Oral Maxillofac Implants, 11, 351 Wiskott, 1999, Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone, Clin Oral Implants Res, 10, 429, 10.1034/j.1600-0501.1999.100601.x Hansson, 1999, The implant neck: smooth or provided with retention elements. A biomechanical approach, Clin Oral Implants Res, 10, 394, 10.1034/j.1600-0501.1999.100506.x Clelland, 1991, Three-dimensional finite element stress analysis in and around the Screw-Vent implant, Int J Oral Maxillofac Implants, 6, 391 Lum, 1992, Load transfer from endosteal implants to supporting bone: an analysis using statics. Part one: Horizontal loading, J Oral Implantol, 18, 343 Clift, 1992, Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus, Proc Inst Mech Eng [H], 206, 233, 10.1243/PIME_PROC_1992_206_295_02 Holmes, 1997, Influence of bone quality on stress distribution for endosseous implants, J Oral Implantol, 23, 104 Papavasiliou, 1996, Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function, J Prosthet Dent, 76, 633, 10.1016/S0022-3913(96)90442-4 Wadamoto, 1996, The three-dimensional bone interface of an osseointegrated implant. I: a morphometric evaluation in initial healing, J Prosthet Dent, 76, 170, 10.1016/S0022-3913(96)90302-9 Clelland, 1993, Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant, J Prosthodont, 2, 183, 10.1111/j.1532-849X.1993.tb00405.x Sakaguchi, 1993, Nonlinear finite element contact analysis of dental implant components, Int J Oral Maxillofac Implants, 8, 655 Jorneus, 1992, Loads and designs of screw joints for single crowns supported by osseointegrated implants, Int J Oral Maxillofac Implants, 7, 353 Haack, 1995, Elongation and preload stress in dental implant abutment screws, Int J Oral Maxillofac Implants, 10, 529 Versluis, 1999, Numerical analysis of a dental implant system preloaded with a washer, Int J Oral Maxillofac Implants, 14, 337 Tan, 1995, The clinical significance of distortion in implant prosthodontics: is there such a thing as passive fit?, Ann Acad Med Singapore, 24, 138 Cheong, 2000 Holmes, 1994, Deflection of superstructure and stress concentrations in the IMZ implant system, Int J Prosthodont, 7, 239 Holmes, 1992, Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis, Int J Oral Maxillofac Implants, 7, 450 Papavasiliou, 1996, Finite element analysis of ceramic abutment-restoration combinations for osseointegrated implants, Int J Prosthodont, 9, 254 Holmes, 1997, Finite element stress analysis of IMZ abutment designs: development of a model, J Prosthodont, 6, 31, 10.1111/j.1532-849X.1997.tb00062.x Haganman, 1997, Deflection and stress distribution in three different IMZ abutment designs, J Prosthodont, 6, 110, 10.1111/j.1532-849X.1997.tb00076.x Canay, 1996, Comparison of stress distribution around vertical and angled implants with finite-element analysis, Quintessence Int, 27, 591 Kregzde, 1993, A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis, Int J Oral Maxillofac Implants, 8, 662 Korioth, 1999, Influence of mandibular superstructure shape on implant stresses during simulated posterior biting, J Prosthet Dent, 82, 67, 10.1016/S0022-3913(99)70129-0 Young, 1998, Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method, Dent Mater, 14, 37, 10.1016/S0109-5641(98)00007-4 Sertgöz, 1996, Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis, J Prosthet Dent, 76, 165, 10.1016/S0022-3913(96)90301-7 Lindquist, 1996, A prospective 15-year follow-up study of mandibular fixed prostheses supported by ossointegrated implants. Clinical results and marginal bone loss, Clin Oral Implants Res, 7, 329, 10.1034/j.1600-0501.1996.070405.x Meijer, 1993, A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible, Arch Oral Biol, 38, 491, 10.1016/0003-9969(93)90185-O Meijer, 1994, Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure, J Oral Rehabil, 21, 47, 10.1111/j.1365-2842.1994.tb01123.x Meijer, 1996, Loading conditions of endosseous implants in an edentulous human mandible: a three-dimensional, finite-element study, J Oral Rehabil, 23, 757, 10.1046/j.1365-2842.1996.d01-185.x Bidez, 1992, Finite element analysis (FEA) studies in 2.5-mm round bar design: the effects of bar length and material composition on bar failure, J Oral Implantol, 18, 122 Bidez, 1993, Finite element analysis of two-abutment Hader bar designs, Implant Dent, 2, 107, 10.1097/00008505-199305000-00008 Bidez, 1993, Finite element analysis of four-abutment Hader bar designs, Implant Dent, 2, 171, 10.1097/00008505-199309000-00005 Menicucci, 1998, Mandibular implant-retained overdenture: finite element analysis of two anchorage systems, Int J Oral Maxillofac Implants, 13, 369 van Rossen, 1990, Stress-absorbing elements in dental implants, J Prosthet Dent, 64, 198, 10.1016/0022-3913(90)90179-G el Charkawi, 1990, Modification of osseointegrated implants for distal-extension prostheses, J Prosthet Dent, 64, 469, 10.1016/0022-3913(90)90046-F Misch, 1993, Finite element stress analysis of tooth-to-implant fixed partial denture designs, J Prosthodont, 2, 83, 10.1111/j.1532-849X.1993.tb00388.x Melo, 1995, Comparative stress analyses of fixed free-end osseointegrated prostheses using the finite element method, J Oral Implantol, 21, 290 Gross, 1997, Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients. Part I: laboratory and clinical studies, J Oral Rehabil, 24, 863, 10.1046/j.1365-2842.1997.00582.x