Study on hybrid ground-coupled heat pump system for air-conditioning in hot-weather areas like Hong Kong

Applied Energy - Tập 87 - Trang 2826-2833 - 2010
Yi Man1, Hongxing Yang1, Jinggang Wang2
1Renewable Energy Research Group, Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
2Hebei University of Engineering, Handan, China

Tài liệu tham khảo

Omer, 2007, Energy environment and sustainable development, Renew Sustain Energy Rev, 10.1016/j.rser.2007.01.003 ASHRAE. Commercial/institutional ground-source heat pump engineering manual. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.; 1995. Gilbreath CS. Hybrid ground-source heat pump systems for commercial applications. Master’s thesis, University of Alabama, Tuscaloosa, Alabama; 1996. Kavanaugh, 1997 Kavanaugh, 1998, A design method for hybrid ground-source heat pumps, ASHRAE Trans, 104, 691 Phetteplace, 1998, Performance of a hybrid ground-coupled heat pump system, ASHRAE Trans, 104, 763 Singh JB, Foster G. Advantages of using the hybrid geothermal option, In: The second stockton international geothermal conference. The Richard Stockton College of New Jersey; 1998. Yavuzturk, 2000, Comparative study of operating and control strategies for hybrid ground-source heat pump systems using a short time step simulation model, ASHRAE Trans, 106, 192 Lewis, 1922, The evaporation of liquid into gas, Trans ASME, 44, 325 Robinson, 1923, The design of cooling towers, Mech Eng, 15, 99 Merkel F. Verdunstungskiihung, VDI Forschungsar beiten, No. 275, Berlin, Germany; 1925. Baker, 1952, Analyzing cooling tower performance by the unit-volume coefficient, Chem Eng Baker, 1961, A comprehensive approach to the analysis of cooling tower performance, J Heat Transfer, 83, 339, 10.1115/1.3682276 Blanchard, 1980, Coefficient of performance for finite-speed heat pump, J Appl Phys, 51, 2471, 10.1063/1.328020 Goth, 1986, Optimum COP for endoreversible heat-pump or refrigerating machine, CR Acad Sci, Paris, 303, 19 Philippi I, Feidt M. Finite-time thermodynamics applied to inverse cycle machines. In: XVIII International congress on refrigeration, Montreal, Canada; 1991. Wu, 1998, Optimization of steady flow heat-pumps, Energ Convers Manage, 39, 445, 10.1016/S0196-8904(97)00025-3 Zeng, 2002, A finite line-source model for boreholes in geothermal heat exchangers, Heat Transfer – Asian Res, 31, 558, 10.1002/htj.10057 Man, 2008, Study on hybrid ground-coupled heat pump systems, Energy Build, 40, 2028, 10.1016/j.enbuild.2008.05.010 Zeng, 2003, Heat transfer analysis of boreholes in vertical ground heat exchangers, Int J Heat Mass Transfer, 46, 4467, 10.1016/S0017-9310(03)00270-9