Fractures of a Single Design of Highly Cross-Linked Polyethylene Acetabular Liners: An Analysis of Voluntary Reports to the United States Food and Drug Administration

Journal of Arthroplasty - Tập 29 - Trang 1231-1235 - 2014
Michael P. Ast1, Thomas K. John1, Anthony Labbisiere1, Nicolas Robador1, Alejandro Gonzalez Della Valle1
1Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York

Tài liệu tham khảo

Affatato, 2005, Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions, Biomaterials, 26–16, 3259, 10.1016/j.biomaterials.2004.07.070 Kurtz, 1999, Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty, Biomaterials, 20, 1659, 10.1016/S0142-9612(99)00053-8 Muratoglu, 2001, A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties: Recipient of the 1999 HAP Paul Award, J Arthroplasty, 16, 149, 10.1054/arth.2001.20540 Beksaç, 2009, Wear is reduced in THA performed with highly cross-linked polyethylene, Clin Orthop Relat Res, 467–7, 1765, 10.1007/s11999-008-0661-1 Jacobs, 2007, Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty, J Bone Joint Surg Am, 89, 2779, 10.2106/JBJS.G.00043 Kurtz, 2011, History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene, Clin Orthop Relat Res, 469, 2262, 10.1007/s11999-011-1872-4 Tower, 2007, Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty, J Bone Joint Surg, 89–10, 2212, 10.2106/JBJS.F.00758 Moore, 2008, Early failure of a cross-linked polyethylene acetabular linera case report, J Bone Joint Surg Case Connector, 90–11, 2499, 10.2106/JBJS.G.01304 Stiehl, 2007, Catastrophic failure of a modular revision total hip polyethylene insert, J Arthroplasty, 22–1, 143, 10.1016/j.arth.2006.02.077 Duffy GP, Wannomae KK, Rowell SL, Muratoglu OK. Fracture of a cross-linked polyethylene liner due to impingement. The Journal of arthroplasty 2009;24–1:158. e15. Blumenfeld TJ, McKellop HA, Schmalzried TP, Billi F. Fracture of a cross-linked polyethylene liner: A multifactorial issue. The Journal of arthroplasty 2011;26–4:666. e5. Waewsawangwong W, Goodman SB. Unexpected failure of highly cross-linked polyethylene acetabular liner. The Journal of arthroplasty 2012;27–2:323. e1. www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/search.cfm. (accessed). Gonzalez DellaValle, 2001, Dislodgment of polyethylene liners in first and second-generation Harris–Galante acetabular components: a report of eighteen cases, J Bone Joint Surg, 83–4, 553, 10.2106/00004623-200104000-00010 Ghelman, 2009, CT outperforms radiography for determination of acetabular cup version after THA, Clin Orthop Relat Res, 467–9, 2362, 10.1007/s11999-009-0774-1 Cipriano, 2008, Metallosis after metal-on-polyethylene total hip arthroplasty, Am J Orthop, 37, E18 Gonzalez Della Valle, 2004, Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty, J Bone Joint Surg, 86–9, 1998, 10.2106/00004623-200409000-00019 Whittaker, 2010, Comparison of steady state femoral head penetration rates between two highly cross-linked polyethylenes in total hip arthroplasty, J Arthroplasty, 25–5, 680, 10.1016/j.arth.2009.05.006 Manning, 2005, In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty, J Arthroplasty, 20–7, 880, 10.1016/j.arth.2005.03.033 D'Antonio, 2012, Second-generation annealed highly cross-linked polyethylene exhibits low wear, Clin Orthop Relat Res, 470–6, 1696, 10.1007/s11999-011-2177-3 Oral, 2006, Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE, Biomaterials, 27, 917, 10.1016/j.biomaterials.2005.06.025 Nakahara, 2010, Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads, J Arthroplasty, 25, 1182, 10.1016/j.arth.2009.09.006 Stulberg, 2012, Bilateral patellar component shear failure of highly cross-linked polyethylene components: report of a case and laboratory analysis of failure mechanisms, J Arthroplasty, 27, 789, 10.1016/j.arth.2011.08.011 Shon, 2005, Impingement in total hip arthroplasty: a study of retrieved acetabular components, J Arthroplasty, 20–4, 427, 10.1016/j.arth.2004.09.058