Early postoperative improvements in the QuickDASH score after distal radius fracture are related to the type of surgical treatment

Springer Science and Business Media LLC - Tập 25 - Trang 865-869 - 2015
François Loisel1,2, Xavier Bouilloux1,2, Julien Uhring1,2, Séverin Rochet1,2, Laurent Obert1,2
1Service d’Orthopédie, de Traumatologie, de Chirurgie Plastique, Reconstructrice et Assistance Main & CIC IT 808, EA 4268 Innovation, Imagerie, Ingénierie et Intervention en santé « I4S » IFR 133 INSERM, C.H.U. Besançon, Besançon, France
2Faculté de médecine et de Pharmacie, Université de Franche Comté, Besançon, France

Tóm tắt

The goal of this prospective study was to evaluate the real-life experience of 52 patients and their recovery kinetics in the first 6 weeks after surgical treatment of distal radius fractures. The fractures were treated with either a fourth-generation volar locking plate (34 patients, mean age 67 years, range 54–82) or by percutaneous pinning (18 patients, mean age 56 years, range 43–69). These patients were evaluated every week for 6 weeks with the QuickDASH (QD) questionnaire. A lower QD score indicated that the patient’s physical function and symptoms had improved. At postoperative week 1, all the patients who had undergone percutaneous pinning had a QD of 80 (out of 100). One-third of patients who had undergone plate fixation had a QD of 80, while the remainder had a QD of 65. Out of all the patients who had a QD of 80 at postoperative week 1, the patients who had undergone plate fixation improved more quickly. After 6 weeks, the patients who had undergone plate fixation had a greater reduction in the QD (50 points) than the ones who had undergone pinning (30 points). Although the direct costs of locking plate fixation are 10 times higher than those of K-wire pinning, evidence suggests that these plates reduce the indirect costs. This study has shown that a patient’s recovery rate, day-to-day life and physical function are better over the first 6 weeks postsurgery when the distal radius fracture is fixed with a locking plate.

Tài liệu tham khảo

Diaz-Garcia RJ, Oda T, Shauver MJ, Chung KC (2011) A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. J Hand Surg 36A:824–835 Lafontaine M, Hardy D, Delince P (1989) Stability assessment of distal radius fractures. Injury 20:208–210 Blakeney WG (2010) Stabilization and treatment of Colles’ fractures in elderly patients. Clin Interv Aging 5:337–344 Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67 Kreder HJ, Hanel DP, McKee M, Jupiter J, McGillivary G, Swiontkowski MF (1996) Consistency of AO fracture classification for the distal radius. J Bone Joint Surg Br 78:726–731 Laulan J, Bismuth JP, Clément P, Garaud P (2007) Classification analytique des fractures de l’extrémité distale du radius: la classification “MEU”. Chir Main 26:293–299 Dubert T, Voche P, Dumontier C, Dinh A (2001) The DASH questionnaire. French translation of a trans-cultural adaptation. Chir Main 20:294–302 Obert L, Rey PB, Uhring J, Gasse N, Rochet S, Lepage D, Serre A, Garbuio P (2013) Fixation of distal radius fractures in adults: a review. Orthop Traumatol Surg Res 99:216–234 Levin SM, Nelson CO, Botts JD et al (2008) Biomechanical evaluation of volar locking plates for distal radius fractures. Hand 3:55–60 Rozenthal TD, Blazar PE (2006) Functionnal outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg 31:359–365 Simic PM, Robinson J, Gardner MJ et al (2006) Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg 31:382–386 Obert L, Uhring J, Rey PB, Rochet S, Lepage D, Leclerc G, Serre A, Garbuio P (2012) Anatomy and biomechanics of distal radius fractures: a literature review. Chir Main 31:287–297 Wright TW, Horodyski M, Smith DW (2005) Functionnal outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg 30A:289–299 Abramo A, Kopylov P, Geijer M, Tägil M (2009) Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures. Acta Orthop 80:478–485 McFayden I, Field J, McCann P et al (2011) Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial. Injury 42:162–166 Huard S, Blanchet N, Leclerc G et al (2010) Les fractures du radius distal après 70 ans: ostéosynthèse par plaque palmaire ou broches? Chir Main 29:236–241 Rizzo M, Katt BA, Carothers JT (2008) Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures. Hand 3:111–117 Schmelzer-Schmied N, Wieloch P, Martini AK, Daecke W (2009) Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly. Int Orthop 33:773–778 Synn AJ, Makhni EC, Makhni MC, Rozenthal TD, Day CS (2009) Distal radius fractures in older patients, Is anatomic reduction Necessary? Clin Orthop Relat Res 467:1612–1620 Kumar S, Penematsa S, Sadri M, Deshmukh SC (2008) Can radiological results be surrogate markers of functional outcome in distal radial extra-articular fractures? Int Orthop 32:505–509 Gong HS, Lee JO, Huh JK, Oh JH, Kim SH, Baek GH (2011) Comparison of depressive symptoms during the early recovery period in patients with a distal radius fracture treated by volar plating and cast immobilisation. Injury 42:1266–1270 Ward CM, Kuhl TL, Adams BD (2011) Early complications of volar plating of distal radius fractures and their relationship to surgeon experience. Hand 6:185–189