Brace for variability in tool positioning: Modeling and simulation of 1 DoF needle insertion task under tool-braced condition
Tài liệu tham khảo
Peral-Gutierrez, 2004, Static and dynamic accuracy of vitreoretinal surgeons, 2734
Mictell, 2007, Development and application of a new steady-hand manipulator for retinal surgery, 623
Sandoval, 2007, Positioning accuracy of neurosurgeons, 206
Kooyman, 2013
Asada, 1985, Design and analysis of braced manipulators for improved stiffness, 307
Book, 1984, The bracing strategy for robot operation, 139
Kwon, 1988, A framework for analysis of a bracing manipulator with staged positioning
Moore, 1983, Part reference manipulation – a strategy applied to robotic drilling, 183
Asada, 1885, Design of an adaptable tool guide for grinding robots, Robot Comp Integr Manuf, 2, 49, 10.1016/0736-5845(85)90007-9
Fields, 1989, Flexible fixuring and automatic drilling of sheet metal parts using a robot manipulator, Robot Comp Integr Manuf, 5, 371, 10.1016/0736-5845(89)90010-0
Molander, 1983, Routing and drilling with an industrial robot, 37
Zupancic, 1998, Comparison of position repeatability of a human operator and an industrial manipulating robot, Comput Biol Med, 28, 415, 10.1016/S0010-4825(98)00019-5
Vanderborght, 2013, Variable impedance actuators: a review, Robot Auton Syst, 61, 1601, 10.1016/j.robot.2013.06.009
Fasse, 1994, A novel variable mechanical impedance electromechanical actuator, Dynam Syst Control, 551, 311
Stramigioli, 2002, A rigorous framework for interactive robot control, Int J Control, 75, 1486, 10.1080/0020717021000032078
Fehlberg, 2012, A large workspace tool for precision manipulation, Int J Robot Res, 31, 289, 10.1177/0278364911432895
Lew, 1994, Bracing micro/macro manipulators control, 2362
Taylor, 1999, A steady-hand robotic system for microsurgical augmentation, Int J Robot Res, 18, 1201, 10.1177/02783649922067807
Shoham, 2003, Bone-mounted miniature robot for surgical procedures: concept and clinical applications, IEEE Trans Robot Autom, 19, 893, 10.1109/TRA.2003.817075
Hogan, 1984, Adaptive control of mechanical impedance by coactivation of antagonist muscles, IEEE Trans Autom Control, 29, 681, 10.1109/TAC.1984.1103644
Franklin, 2003, Adaptive control of stiffness to stabilize hand position with large loads, Exp Brain Res, 152, 211, 10.1007/s00221-003-1540-3
Gomi, 1998, Task-dependent viscoelasticity of human multijoint arm and its spatial characteristics for interaction with environments, J Neurosci, 18, 8965, 10.1523/JNEUROSCI.18-21-08965.1998
Nichols, 1976, Improvement in linearity and regulation of stiffness that results from actions of stretch reflex, J Neurophysiol, 39, 119, 10.1152/jn.1976.39.1.119
Hogan, 1985, The mechanics of multi-joint posture and movement control, Biol Cybern, 52, 315, 10.1007/BF00355754
Takahashi, 2001, Impedance control and internal model formation when reaching in a randomly varying dynamical environment, J Neurophysiol, 86, 1047, 10.1152/jn.2001.86.2.1047
Bizzi, 1992, Does the nervous system use equilibrium-point control to guide single and multiple joint movements?, Behav Brain Sci, 15, 603, 10.1017/S0140525X00072538
Mohammad, 2014, Effects of bracing on pointing task accuracy
Gerovich, 2004, The effect of visual and haptic feedback on computer-assisted needle insertion, Comput Aided Surg, 9, 243, 10.3109/10929080500190441
Deary, 2011, A free, easy-to-use, computer-based simple and four-choice reaction time programme: the Deary-Liewald reaction time task, Behav Res Methods, 43, 258, 10.3758/s13428-010-0024-1
McIvor, 2013