Predicting cancellous bone failure during screw insertion
Tài liệu tham khảo
Beaupre, 1988, Stresses in plated long-bones: the role of screw tightness and interface slipping, Journal of Orthopaedic Research, 6, 39, 10.1002/jor.1100060106
Carter, 1984, Changes in long-bone structural properties during the first 8 weeks of plate implantation, Journal of Orthopaedic Research, 2, 80, 10.1002/jor.1100020113
Cheal, 1991, Role of interfragmentary strain in fracture healing: ovine model of a healing osteotomy, Journal of Orthopaedic Research, 9, 131, 10.1002/jor.1100090116
Chen, 2011, Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling, BMC Musculoskeletal Disorders, 12, 33, 10.1186/1471-2474-12-33
Cleek, 2007, Effect of screw torque level on cortical bone pullout strength, Journal of Orthopaedic Trauma, 21, 117, 10.1097/BOT.0b013e318030261e
Cordey, 1978
Cordey, 1980
Drew, 2002, A new method of fixation in osteoporotic bone. A preliminary report, Injury, 33, 685, 10.1016/S0020-1383(02)00047-5
Frandsen, 1984, Holding power of different screws in the femoral head: a study in human cadaver hips, Acta Orthopaedica, 55, 349, 10.3109/17453678408992372
Hashemi, 2009, Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study, The Spine Journal, 9, 404, 10.1016/j.spinee.2008.07.001
Jacobs, 1981, Effect of plates on cortical bone perfusion, The Journal of Trauma, 21, 91, 10.1097/00005373-198102000-00001
Lawson, 2001, Effect of insertion torque on bone screw pullout strength, Orthopedics, 24, 451, 10.3928/0147-7447-20010501-12
McGuire, 1995, Analysis of the torque applied to bone screws by trauma surgeons. Comparisons based on years of experience and material of implant construction, The American Journal of Orthopaedics, 24, 254
Perren, 1980
Ryken, 1995, Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws, Journal of Neurosurgery, 83, 324, 10.3171/jns.1995.83.2.0324
Suhm, 2007, Mechanical torque measurement predicts load to implant cut-out: a biomechanical study investigating DHS® anchorage in femoral heads, Archives of Orthopaedic and Trauma Surgery, 127, 469, 10.1007/s00402-006-0265-8
Thomas, 2008, Automated surgical screwdriver: automated screw placement, Journal of Engineering in Medicine, 222, 817, 10.1243/09544119JEIM375
Von Arx, 1975, Force transmission through friction in plate osteosynthesis, AO-Bulletin, 1