Parametric analysis of influence of courtyard microclimate on diminution of convective heat transfer through building’s envelope
Tóm tắt
The growing trend of using glass facade and the low thermal resistance of this material, has increased the importance of environmental loads on heat loss through the building’s envelope. In this regards, creating microclimate spaces between buildings acts as a shelter against wind and sun, and thus convective and radiative heat transfer. In this research, computational fluid dynamics microclimate software ENVI-met has been used to consider the relationship between optimum courtyard forms in decreasing the convective heat transfer coefficient (CHTC). A simple linear correlation was used to calculate the hc (W·m−2·K−1) based on the wind speed (WS) near the facade within the courtyard. The outcome of the research reveals that the microclimate of the courtyard, particularly for the strong ambient winds (U10), can diminish the CHTC in comparison with exposed surfaces. Moreover, among various design alternatives, the aspect ratio has a significant impact on WS and CHTC. It was observed that, for U10 = 2.3 (m·s−1), as aspect ratio (H/W) increases from 0.67 to 3.67, the average surface WS, up to the middle floor, on the windward and leeward facade inside the courtyard, located in Hanover, reduces by about 75%. This suggests that an appropriate selection of the courtyard geometry will help passively reduce cooling load and let designers use less thickly insulated walls.
Tài liệu tham khảo
Al-Hafith O, Satish BK, Bradbury S, de Wilde P (2017). The Impact of Courtyard parameters on its shading level An experimental study in Baghdad, Iraq. Energy Procedia, 134: 99–109.
Allegrini J, Dorer V, Defraeye T, Carmeliet J (2012). An adaptive temperature wall function for mixed convective flows at exterior surfaces of buildings in street canyons. Building and Environment, 49: 55–66.
Almhafdy A, Ibrahim N, Ahmad SS, Yahya J (2015). Thermal performance analysis of courtyards in a hot humid climate using computational fluid dynamics CFD method. Procedia — Social and Behavioral Sciences, 170: 474–483.
Alvarez S, Sanchez F, Molina JL (1998). Air flow pattern at courtyards. In: Proceedings of PLEA’98, Environmentally Friendly Cities, Lisbon, Portugal, pp. 503–506.
Assimakopoulos VD, ApSimon HM, Moussiopoulos N (2003). A numerical study of atmospheric pollutant dispersion in different two-dimensional street canyon configurations. Atmospheric Environment, 37: 4037–4049.
Azizi MM, Javanmardi K (2017). The effects of urban block forms on the patterns of wind and natural ventilation. Procedia Engineering, 180: 541–549.
Badas MG, Ferrari S, Garau M, Querzoli G (2017). On the effect of gable roof on natural ventilation in two-dimensional urban canyons. Journal of Wind Engineering and Industrial Aerodynamics, 162: 24–34.
Baldwin B, Lomax H (1978). Thin-layer approximation and algebraic model for separated turbulentflows. In: Proceedings of the 16th Aerospace Sciences Meeting. American Institute of Aeronautics and Astronautics.
Battista G (2017). Analysis of convective heat transfer at building facades in street canyons. Energy Procedia, 113: 166–173.
Berkovic S, Yezioro A, Bitan A (2012). Study of thermal comfort in courtyards in a hot arid climate. Solar Energy, 86: 1173–1186.
Blocken B, Defraeye T, Derome D, Carmeliet J (2009). High-resolution CFD simulations for forced convective heat transfer coefficients at the facade of a low-rise building. Building and Environment, 44: 2396–2412.
Bornstein RD, Johnson DS (1977). Urban-rural wind velocity differences. Atmospheric Environment, 11: 597–604.
Bouyer J, Inard C, Musy M (2011). Microclimatic coupling as a solution to improve building energy simulation in an urban context. Energy and Buildings, 43: 1549–1559.
Bruse M (1999). Die Auswirkungen kleinskaliger Umweltgestaltung auf das Mikroklima. PhD Thesis, Ruhr-University Bochum, Germany.
Bruse M (2004). ENVI-met Documentation.
Bruse M (2016). ENVI_met. A holistic microclimate model. Available at https://doi.org/www.model.envi-met.com/hg2e/doku.php?id=intro:modelconept. Accessed 1 Sept 2016.
Cermak JE (1996). Thermal effects on flow and dispersion over urban areas: Capabilities for prediction by physical modeling. Atmospheric Environment, 30: 393–401.
Chew LW, Nazarian N, Norford L (2017). Pedestrian-level urban wind flow enhancement with wind catchers. Atmosphere, 8: 159.
Colucci C, Mauri L, Grignaffini S, Romagna M, Cedola L, Kanna R (2017). Influence of the facades convective heat transfer coefficients on the thermal energy demand for an urban street canyon building. Energy Procedia, 126: 10–17.
Davies MG (2004). Building Heat Transfer. Chichester, UK: John Wiley & Sons.
de la Flor FS, Domínguez SA (2004). Modelling microclimate in urban environments and assessing its influence on the performance of surrounding buildings. Energy and Buildings, 36: 403–413.
De Ridder K, Acero JA, Lauwaet D, Lefebvre W, Maiheu B, Mendizabal M (2014). WP 4: Climate change scenarios for urban agglomerations D4. 1: Validation of agglomeration-scale climate projections. RAMSES — Science for cities in transition.
Defraeye T, Blocken B, Carmeliet J (2010). CFD analysis of convective heat transfer at the surfaces of a cube immersed in a turbulent boundary layer. International Journal of Heat and Mass Transfer, 53: 297–308.
Defraeye T, Blocken B, Carmeliet J (2011). Convective heat transfer coefficients for exterior building surfaces: Existing correlations and CFD modelling. Energy Conversion and Management, 52: 512–522.
Defraeye T, Carmeliet J (2010). A methodology to assess the influence of local wind conditions and building orientation on the convective heat transfer at building surfaces. Environmental Modelling & Software, 25: 1813–1824.
DIN (2003). DIN 4108-2. Berlin: Deutsches Institut für Normung e. V.
DIN (2015). DIN EN ISO 6946. Berlin.
Doty S, Turner WC (2013). Energy Management Handbook, 8th edn. The Fairmont Press.
Dumitrescu L, Baran I, Pescaru RA (2017). The influence of thermal bridges in the process of buildings thermal rehabilitation. Procedia Engineering, 181: 682–689.
Eliasson I, Offerle B, Grimmond CSB, Lindqvist S (2006). Wind fields and turbulence statistics in an urban street canyon. Atmospheric Environment, 40: 1–16.
Emmel MG, Abadie MO, Mendes N (2007). New external convective heat transfer coefficient correlations for isolated low-rise buildings. Energy and Buildings, 39: 335–342.
Erell E, Pearlmutter D, Williamson T (2012). urban microclimate: Designing the spaces between buildings. Abingdon UK: Taylor & Francis.
Forouzandeh A (2018). Numerical modeling validation for the microclimate thermal condition of semi-closed courtyard spaces between buildings. Sustainable Cities and Society, 36: 327–345.
Franke J, Hellsten A, Schlünzen H, Carissimo B (2007). Best Practice Guideline for the CFD Simulation of Flows in the Urban Environment. Brussel, Belgium.
Ghaffarianhoseini A, Berardi U, Ghaffarianhoseini A (2015). Thermal performance characteristics of unshaded courtyards in hot and humid climates. Building and Environment, 87: 154–168.
Grobman YJ, Elimelech Y (2016). Microclimate on building envelopes: testing geometry manipulations as an approach for increasing building envelopes’ thermal performance. Architectural Science Review, 59: 269–278.
Hagishima A, Tanimoto J (2003). Field measurements for estimating the convective heat transfer coefficient at building surfaces. Building and Environment, 38: 873–881.
Hagishima A, Tanimoto J, Narita KI (2005). Intercomparisons of experimental convective heat transfer coefficients and mass transfer coefficients of urban surfaces. Boundary-Layer Meteorology, 117: 551–576.
Hall DJ, Walker S, Spanton AM (1999). Dispersion from courtyards and other enclosed spaces. Atmospheric Environment, 33: 1187–1203.
He Y, Monahan AH, McFarlane NA (2013). Diurnal variations of land surface wind speed probability distributions under clear-sky and low-cloud conditions. Geophysical Research Letters, 40: 3308–3314.
Hu Z-X, Cui G-X, Zhang Z-S (2018). Numerical study of mixed convective heat transfer coefficients for building cluster. Journal of Wind Engineering and Industrial Aerodynamics, 172: 170–180.
Huttner S (2012). Further development and application of the 3D microclimate simulation ENVI-met. PhD Thesis, Johannes Gutenberg University Mainz, Germany.
Ince NZ, Launder BE (1995). Three-dimensional and heat-loss effects on turbulent flow in a nominally two-dimensional cavity. International Journal of Heat and Fluid Flow, 16: 171–177.
IMUK (2016). Weather & Climate > Measurement Data. Available at https://doi.org/www.muk.uni-hannover.de/258.html?&L=1. Accessed 1 Jan 2017.
Kottek M, Grieser J, Beck C, Rudolf B, Rubel F (2006). World Map of the Köppen-Geiger climate classification updated. Meteorologische Zeitschrift, 15: 259–263.
Krüger EL, Minella FO, Rasia F (2011). Impact of urban geometry on outdoor thermal comfort and air quality from field measurements in Curitiba, Brazil. Building and Environment, 46: 621–634.
Launder BE, Spalding DB (1974). The numerical computation of turbulent flows. Computer Methods in Applied Mechanics and Engineering, 3: 269–289.
Liu J, Chen JM, Black TA, Novak MD (1996). E-ε modelling of turbulent air flow downwind of a model forest edge. Boundary-Layer Meteorology, 77: 21–44.
Liu Y, Harris DJ (2007). Full-scale measurements of convective coefficient on external surface of a low-rise building in sheltered conditions. Building and Environment, 42: 2718–2736.
Liu J, Heidarinejad M, Gracik S, Srebric J (2015). The impact of exterior surface convective heat transfer coefficients on the building energy consumption in urban neighborhoods with different plan area densities. Energy and Buildings, 86: 449–463.
Long L, Ye H (2016). The roles of thermal insulation and heat storage in the energy performance of the wall materials: A simulation study. Scientific Reports, 6: 24181.
Louka P, Belcher SE, Harrison RG (1998). Modified street canyon flow. Journal of Wind Engineering and Industrial Aerodynamics, 74–76: 485–493.
Louka P, Belcher SE, Harrison RG (2000). Coupling between air flow in streets and the well-developed boundary layer aloft. Atmospheric Environment, 34: 2613–2621.
Loukaidou K, Michopoulos A, Zachariadis T (2017). Nearly-zero energy buildings: cost-optimal analysis of building envelope characteristics. Procedia Environmental Sciences, 38: 20–27.
Loveday DL, Taki AH (1998). Outside surface resistance: Proposed new value for building design. Building Services Engineering Research and Technology, 19: 23–29.
Mauree D, Coccolo S, Kaempf J, Scartezzini J-L (2017). Multi-scale modelling to evaluate building energy consumption at the neighbourhood scale. PLoS ONE, 12(9): e0183437.
Mellor GL, Yamada T (1974). A hierarchy of turbulence closure models for planetary boundary layers. Journal of the Atmospheric Sciences, 31: 1791–1806.
Micallef D, Buhagiar V, Borg SP (2016). Cross-ventilation of a room in a courtyard building. Energy and Buildings, 133: 658–669.
Mirsadeghi M, Cóstola D, Blocken B, Hensen JLM (2013). Review of external convective heat transfer coefficient models in building energy simulation programs: Implementation and uncertainty. Applied Thermal Engineering, 56: 134–151.
Montavon M (2010). Optimisation of urban form by the evaluation of the solar potentia. PhD Thesis, EPFL, switzerland.
Montazeri H, Blocken B (2017). New generalized expressions for forced convective heat transfer coefficients at building facades and roofs. Building and Environment, 119: 153–168.
Moonen P, Dorer V, Carmeliet J (2011). Evaluation of the ventilation potential of courtyards and urban street canyons using RANS and LES. Journal of Wind Engineering and Industrial Aerodynamics, 99: 414–423.
Muhaisen AS, Gadi MB (2006). Effect of courtyard proportions on solar heat gain and energy requirement in the temperate climate of Rome. Building and Environment, 41: 245–253.
Murakami S (1990). Computational wind engineering. Journal of Wind Engineering and Industrial Aerodynamics, 36: 517–538.
Nunez M, Oke TR (1977). The energy balance of an urban canyon. Journal of Applied Meteorology, 16: 11–19.
Palyvos JA (2008). A survey of wind convection coefficient correlations for building envelope energy systems’ modeling. Applied Thermal Engineering, 28: 801–808.
Rafailidis S (1997). Influence of building areal density and roof shape on the wind characteristics above a town. Boundary-Layer Meteorology, 85: 255–271.
Rajapaksha I, Nagai H, Okumiya M (2003). A ventilated courtyard as a passive cooling strategy in the warm humid tropics. Renewable Energy, 28: 1755–1778.
Rodríguez-Algeciras J, Tablada A, Chaos-Yeras M, de la Paz G, Matzarakis A (2018). Influence of aspect ratio and orientation on large courtyard thermal conditions in the historical centre of Camagüey-Cuba. Renewable Energy, 125: 840–856.
Rojas JM, Galán-Marín C, Fernández-Nieto ED (2012). Parametric study of thermodynamics in the mediterranean courtyard as a tool for the design of eco-efficient buildings. Energies, 5: 2381–2403.
Salim SM, Buccolieri R, Chan A, di Sabatino S (2011). Numerical simulation of atmospheric pollutant dispersion in an urban street canyon: Comparison between RANS and LES. Journal of Wind Engineering and Industrial Aerodynamics, 99: 103–113.
Sanyal P, Dalui SK (2018). Effects of courtyard and opening on a rectangular plan shaped tall building under wind load. International Journal of Advanced Structural Engineering, 10: 169–188.
Sharples S (1984). Full-scale measurements of convective energy losses from exterior building surfaces. Building and Environment, 19: 31–39.
Simon H (2016). Modeling urban microclimate: Development, implementation and evaluation of new and improved calculation methods for the urban microclimate model ENVI-met. PhD Thesis, Johannes Gutenberg University Mainz, Germany.
Sini JF, Anquetin S, Mestayer PG (1996). Pollutant dispersion and thermal effects in urban street canyons. Atmospheric Environment, 30: 2659–2677.
Soflaei F, Shokouhian M, Abraveshdar H, Alipour A (2017). The impact of courtyard design variants on shading performance in hot-arid climates of Iran. Energy and Buildings, 143: 71–83.
Srivanit M, Hokao K (2013). Evaluating the cooling effects of greening for improving the outdoor thermal environment at an institutional campus in the summer. Building and Environment, 66: 158–172.
Straube J (2011). BSD-011: Thermal Control in Buildings. Building Science Corporation. Available at https://doi.org/buildingscience.com/documents/digests/bsd-011-thermal-control-in-buildings.
Tablada A, Blocken B, Carmeliet J, Troyer FDE, Verschure H (2005). Geometry of building’s courtyards to favour natural ventilation: comparison between wind tunnel experiment and numerical simulation. In: Proceedings of World Sustainable Building Conference, Tokyo, Japan.
Taleghani M, Tenpierik M, van den Dobbelsteen A, Sailor DJ (2014). Heat in courtyards: A validated and calibrated parametric study of heat mitigation strategies for urban courtyards in the Netherlands. Solar Energy, 103: 108–124.
TERI (2004). Sustainable Building — Design Manual: Sustainable Building Design Practices. New Delhi, India: Energy and Resources Institute.
Terjung WH, O’Rourke PA (1980). Simulating the causal elements of urban heat islands. Boundary-Layer Meteorology, 19: 93–118.
Tominaga Y, Mochida A, Yoshie R, Kataoka H, Nozu T, Yoshikawa M, Shirasawa T (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96: 1749–1761.
Toparlar Y, Blocken B, Maiheu B, van Heijst GJF (2017). A review on the CFD analysis of urban microclimate. Renewable and Sustainable Energy Reviews, 80: 1613–1640.
Toudert FA (2005). Dependence of Outdoor Thermal Comfort on Street Design in Hot and Dry Climate. Berichte des Meteorologischen Institutes der Universität Freibur, Nr. 15.
Wang F, Liu Y (2002). Thermal environment of the courtyard style cave dwelling in winter. Energy and Buildings, 34: 985–1001.
Wilson JD (1988). A second-order closure model for flow through vegetation. Boundary-Layer Meteorology, 42: 371–392.
Wong NH, Feriadi H, Tham KW, Sekhar C, Cheong KW (2000). Natural ventilation characteristics of courtyard buildings in Singapore. In: Proceedings of the 7th International Conference on Air Distribution in Rooms (ROOMVENT 2000), pp. 1213–1218.
Xie X, Huang Z, Wang J, Xie Z (2005). The impact of solar radiation and street layout on pollutant dispersion in street canyon. Building and Environment, 40: 201–212.
Xie J, Cui Y, Liu J, Wang J, Zhang H (2018). Study on convective heat transfer coefficient on vertical external surface of island-reef building based on naphthalene sublimation method. Energy and Buildings, 158: 300–309.
Yang W, Zhu X, Liu J (2017). Annual experimental research on convective heat transfer coefficient of exterior surface of building external wall. Energy and Buildings, 155: 207–214.
Yassin MF (2011). Impact of height and shape of building roof on air quality in urban street canyons. Atmospheric Environment, 45: 5220–5229.
Yoshie R, Mochida A, Tominaga Y, Kataoka H, Harimoto K, Nozu T, Shirasawa T (2007). Cooperative project for CFD prediction of pedestrian wind environment in the Architectural Institute of Japan. Journal of Wind Engineering and Industrial Aerodynamics, 95: 1551–1578.
Zhang L, Zhang N, Zhao F, Chen Y (2004). A genetic-algorithm-based experimental technique for determining heat transfer coefficient of exterior wall surface. Applied Thermal Engineering, 24: 339–349.