Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy

Applied Radiation and Isotopes - Tập 67 - Trang 1683-1685 - 2009
Rajesh A. Kinhikar1, Vedang Murthy2, Vineeta Goel2, Chandrashekar M. Tambe1, Dipak S. Dhote3, Deepak D. Deshpande1
1Department of Medical Physics, Tata Memorial Centre, Parel, Mumbai 400012, India
2Department of Radiation Oncology, Tata Memorial Centre, Parel, Mumbai 400012, India
3Department of Electronics, Brijlal Biyani Science College, Amravati, Maharashtra, India

Tài liệu tham khảo

Amanda, 2008, MOSFET detectors in quality assurance of tomotherapy treatments, Radiother. Oncol., 86, 242, 10.1016/j.radonc.2007.10.025 Bloemen-vanGurp, 2003, Clinical dosimetry with MOSFET dosimeters to determine the dose along the field junction in a split beam technique, Radiother. Oncol., 67, 351, 10.1016/S0167-8140(03)00035-5 Butson, 1996, A new radiotherapy surface dose detector: the MOSFET, Med. Phys., 23, 655, 10.1118/1.597702 Cheung, 2004, Effects of temperature variation on MOSFET dosimetry, Phys. Med. Biol., 49, N191, 10.1088/0031-9155/49/13/N02 Chuang, 2002, Investigation of the use of MOSFET for clinical IMRT dosimetric verification, Med. Phys., 29, 1109, 10.1118/1.1481520 Chung, 2005, Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer, Med. Phys., 32, 2682, 10.1118/1.1992067 Essers, 1999, In vivo dosimetry during external photon beam radiotherapy, Int. J. Radiat. Oncol. Biol. Phys., 43, 245, 10.1016/S0360-3016(98)00341-1 Fairbanks, 1993, Thermoluminescent characteristics of LiF: Mg, Ti from three manufacturers, Med. Phys., 20, 729, 10.1118/1.597023 Higgins, 2003, In vivo diode dosimetry for routine quality assurance in IMRT, Med. Phys., 30, 3118, 10.1118/1.1626989 Jornet, 2004, Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18MV X-ray beams, Med. Phys., 31, 2534, 10.1118/1.1785452 Kron, 1993, Readout thermoluminescence dosimetry chips using contact planchet heater, Australas. Phys. Eng. Sci. Med., 16, 137 Kron, 1996, TLD extrapolation for skin dose determination in vivo, Radiother. Oncol., 41, 119, 10.1016/S0167-8140(96)01795-1 Lee, 2002, Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma, Int. J. Radiat. Oncol. Biol. Phys., 53, 630, 10.1016/S0360-3016(02)02756-6 Mackie, 1993, Tomotherapy: a new concept in the delivery of dynamic conformal radiotherapy, Med. Phys., 20, 1709, 10.1118/1.596958 Marcie, 2005, In vivo measurements with MOSFET detectors in oropharynx and nasopharynx intensity-modulated radiation therapy, Int. J. Radiat. Oncol. Biol. Phys., 61, 1603, 10.1016/j.ijrobp.2004.12.034 McGhee, 1993, An efficient approach to routine TL dosimetry, Med. Dosim., 18, 187, 10.1016/0958-3947(93)90005-E Ramaseshan, 1997, Clinical dosimetry using MOSFETs, Int. J. Radiat. Oncol. Biol. Phys., 37, 959, 10.1016/S0360-3016(96)00600-1 Ramaseshan, 2004, Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy, Phys. Med. Biol., 49, 4031, 10.1088/0031-9155/49/17/014 Scalchi, 1998, Calibration of a MOSFET detection system for 6-MV in vivo dosimetry, Int. J. Radiat. Oncol. Biol. Phys., 40, 987, 10.1016/S0360-3016(97)00894-8 Scalchi, 2005, Characterization of a new MOSFET detector configuration for in vivo skin dosimetry, Med. Phys., 32, 1571, 10.1118/1.1924328 Soubra, 1994, Evaluation of dual bias dual metal oxide–silicon semiconductor field effect transistor detector as radiation dosimeter, Med. Phys., 21, 567, 10.1118/1.597314 TG-51 AAPM, 1999. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med. Phys. 26, 1847–1870. Thomas, 2004, The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT), Phys. Med. Biol., 49, 4919, 10.1088/0031-9155/49/21/005 Wood, 1995, Factors affecting the precision of TLD dose measurements using an automatic TLD reader, Phys. Med. Biol., 40, 309, 10.1088/0031-9155/40/2/009