Minimum Five-Year Follow-Up Wear Measurement of Longevity Highly Cross-Linked Polyethylene Cup Against Cobalt-Chromium or Zirconia Heads

Journal of Arthroplasty - Tập 25 - Trang 1182-1187 - 2010
Ichiro Nakahara1, Nobuo Nakamura2, Takashi Nishii1,3, Hidenobu Miki4, Takashi Sakai1, Nobuhiko Sugano1,3
1Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
2Department of Orthopaedic Surgery, Kyowakai Hospital, Osaka, Japan
3Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
4Department of Orthopaedic Surgery, Osaka National Hospital, Osaka, Japan

Tài liệu tham khảo

Dumbleton, 2002, A literature review of the association between wear rate and osteolysis in total hip arthroplasty, J Arthroplasty, 17, 649, 10.1054/arth.2002.33664 Harris, 1995, The problem is osteolysis, Clin Orthop Relat Res, 311, 46 Muratoglu, 2001, A novel method of cross-linking UHMWPE to improve wear, reduce oxidation, and retain mechanical properties, J Arthroplasty, 16, 149, 10.1054/arth.2001.20540 Harris, 2004, Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros, Clin Orthop Relat Res, 429, 63, 10.1097/01.blo.0000149827.55160.42 McKellop, 1999, Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements, J Orthop Res, 17, 157, 10.1002/jor.1100170203 Kumar, 1991, Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy, J Biomed Mater Res, 25, 813, 10.1002/jbm.820250703 Skinner, 1999, Ceramic bearing surfaces, Clin Orthop Relat Res, 369, 83, 10.1097/00003086-199912000-00009 Zichner, 1992, Comparison of alumina-polyethylene and metal-polyethylene in clinical trials, Clin Orthop Relat Res, 282, 86, 10.1097/00003086-199209000-00011 Schuller, 1990, Ten-year socket wear in 66 hip arthroplasties. Ceramic versus metal heads, Acta Orthop Scand, 61, 240, 10.3109/17453679008993508 Callaway, 1995, Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty, J Arthroplasty, 10, 855, 10.1016/S0883-5403(05)80087-7 Fritsch, 1996, Ceramic femoral head fractures in total hip arthroplasty, Clin Orthop Relat Res, 328, 129, 10.1097/00003086-199607000-00021 Cales, 2000, Zirconia as a sliding material: histologic, laboratory, and clinical data, Clin Orthop Relat Res, 379, 94, 10.1097/00003086-200010000-00013 Christel, 1989, Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia, J Biomed Mater Res, 23, 45, 10.1002/jbm.820230105 Kim, 2005, Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. a prospective, randomized study, J Bone Joint Surg Am, 87, 1769, 10.2106/JBJS.D.02572 Manning, 2005, In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty, J Arthroplasty, 20, 880, 10.1016/j.arth.2005.03.033 Bragdon, 2006, Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up, J Arthroplasty, 21, 935, 10.1016/j.arth.2006.01.006 Dorr, 2005, Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years, J Bone Joint Surg Am, 87, 1816, 10.2106/JBJS.D.01915 D'Antonio, 2005, Five-year experience with Crossfire highly cross-linked polyethylene, Clin Orthop Relat Res, 441, 143, 10.1097/00003086-200512000-00024 Martell, 2003, Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial, J Arthroplasty, 18, 55, 10.1016/S0883-5403(03)00341-3 Digas, 2004, The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis, Clin Orthop Relat Res, 429, 6, 10.1097/01.blo.0000150314.70919.e3 Merle d'Aubigne, 1954, Functional results of hip arthroplasty with acrylic prosthesis, J Bone Joint Surg, 36, 451, 10.2106/00004623-195436030-00001 Amstutz, 1984, Treatment of primary osteoarthritis of the hip. a comparison of total joint and surface replacement arthroplasty, J Bone Joint Surg Am, 66, 228, 10.2106/00004623-198466020-00010 DeLee, 1976, Radiological demarcation of cemented sockets in total hip replacement, Clin Orthop Relat Res, 121, 20 Gruen, 1979, “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening, Clin Orthop, 141, 17 Devane, 1999, Assessment of polyethylene wear in total hip replacement, Clin Orthop Relat Res., 369, 59, 10.1097/00003086-199912000-00007 Geller, 2006, Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results, Clin Orthop Relat Res, 447, 53, 10.1097/01.blo.0000218742.61624.80 Livermore, 1990, Effect of femoral head size on wear of the polyethylene acetabular component, J Bone Joint Surg Am, 72, 518, 10.2106/00004623-199072040-00008 Pedersen, 2001, Comparison of femoral head penetration rates between cementless acetabular components with 22-mm and 28-mm heads, J Arthroplasty, 16, 111, 10.1054/arth.2001.28372 Muratoglu, 2001, Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept, J Arthroplasty, 16, 24, 10.1054/arth.2001.28376 Minakawa, 1998, Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head, J Bone Joint Surg Br, 80, 894, 10.1302/0301-620X.80B5.8675 Clarke, 2003, Current status of zirconia used in total hip implants, J Bone Joint Surg Am, 85, 73, 10.2106/00004623-200300004-00009 Haraguchi, 2001, Phase transformation of zirconia ceramic head after total hip arthroplasty, J Bone Joint Surg Br, 83, 996, 10.1302/0301-620X.83B7.12122 Allain, 1999, Poor eight-year survival of cemented zirconia-polyethylene total hip replacements, J Bone Joint Surg Br, 81, 835, 10.1302/0301-620X.81B5.9454 Hernigou, 2003, Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up, J Bone Joint Surg Br, 85, 504, 10.1302/0301-620X.85B4.13397 Kraay, 2006, Zirconia versus Co-Cr femoral heads in total hip arthroplasty: early assessment of wear, Clin Orthop Relat Res, 453, 86, 10.1097/01.blo.0000246544.95316.1f Hayaishi, 2008, Phase transformation of a new generation yttria-stabilized zirconia femoral head after total hip arthroplasty, Mod Rheumatol, 18, 647, 10.1007/s10165-008-0108-2 Moore, 2000, The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty, J Bone Joint Surg Am, 82, 62, 10.2106/00004623-200001000-00008