Lateral performance of mortise-tenon jointed traditional timber frames with wood panel infill

Engineering Structures - Tập 161 - Trang 223-230 - 2018
Emile Crayssac1,2, Xiaobin Song1, Yajie Wu1, Kai Li1
1Department of Structural Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China
2University of Lyon/Ecole Nationale des Travaux Publics de l’Etat (ENTPE), Lyon, France

Tài liệu tham khảo

Liang, 1984 Song XB, Wu YJ, Gu XL, Luo L. Mechanical behavior of traditional Chinese wood-to-wood connections: a brief review. In: Proceedings of 2016 World Conference on Timber Engineering, Vienna, Austria; 2016. Li J. Treatise on architectural methods or state building standards. Kaifeng, China: Royal Press. [in ancient Chinese], 1100. Ma, 1991 Wang, 1992 Chun, 2011, Experimental study on seismic characteristics of typical mortise-tenon joints of Chinese southern traditional timber frame buildings, Sci China Technol Sci, 54, 2404, 10.1007/s11431-011-4448-3 Xu, 2014, Experimental study on seismic behavior of wooden frame structures in the Ming and Qing dynasties of China, World Earthq Eng, 30, 155 Fang, 2001, Ancient Chinese timber architecture. I: experimental study, J Struct Eng, 127, 1348, 10.1061/(ASCE)0733-9445(2001)127:11(1348) Fang, 2001, Ancient Chinese timber architecture. II: dynamic characteristics, J Struct Eng, 127, 1358, 10.1061/(ASCE)0733-9445(2001)127:11(1358) King, 1996, Joint characteristics of traditional Chinese wooden frames, Eng Struct, 18, 635, 10.1016/0141-0296(96)00203-9 Chang, 2006, Rotational performance of traditional Nuki joints with gap I: theory and verification, J Wood Sci, 52, 58, 10.1007/s10086-005-0734-7 Seo, 1999, Static and cyclic behavior of wooden frames with tenon joints under lateral load, J Struct Eng, 125, 344, 10.1061/(ASCE)0733-9445(1999)125:3(344) Tsuwa, 2012, 45 Suzuki, 2006, Structural mechanism of traditional wooden frames by dynamic and static tests, Struct Control Health Monit, 13, 508, 10.1002/stc.153 Vasconcelos, 2013, In-plane shear behaviour of traditional timber walls, Eng Struct, 56, 1028, 10.1016/j.engstruct.2013.05.017 Branco, 2014, Cyclic behavior of composite timber-masonry wall in quasi-dynamic conditions reinforced with superelastic damper, Constr Build Mater, 52, 166, 10.1016/j.conbuildmat.2013.10.095 Dutu, 2015, In-plane behavior of timber frames with masonry infills under static cyclic loading, J Struct Eng, 04015140 Xu, 2015, Experimental research on seismic performance of mortise-tenon joint wood frame with brick masonry infilled wall, J Build Struct, 45, 50 Luo L, Song XB, Wu HB. Experimental study on mechanical performance of wood pegged semi mortise and tenon connection. In: Proceedings of the World Conference on Timber Engineering, Vienna, Austria; 2016. Krawinkler, 2001 Song, 2017, Shaking table test on a traditional pavilion-style wooden pagoda, J Build Struct, 38, 10 Wu YJ, Song XB, Luo L. Experimental investigation on the seismic performance of a Chinese traditional wooden pagoda. In: The 2nd ICCASCE, Busan, South Korea; 2016. American Society for Testing and Materials (ASTM). 2005a. ASTM E 2126–05. Standard test method for cyclic (reversed) load test for shear resistance of walls for buildings. Annual Book of ASTM Standards. West Conshohocken, PA, USA: ASTM. Harding N, Fowkes AHR. Bolted timber joints. In: Proceedings of the Pacific Timber Engineering Conference, 1984, May, Auckland, New Zealand. p. 872–883. Heine, 2001 China Academy of Building Research. Specification of test methods for earthquake resistant building. JGJ101-96, Beijing; 1996.