Ground coupled heat exchangers: A review and applications

Renewable and Sustainable Energy Reviews - Tập 47 - Trang 83-92 - 2015
Suresh Kumar Soni1, Mukesh Pandey1, V. N. Bartaria2
1Department of Energy Technology, RGPV, Bhopal, India
2Department of Mechanical Engineering, LNCT, Bhopal, India

Tóm tắt

Từ khóa


Tài liệu tham khảo

Omer, 2008, Energy, environment and sustainable development, Renew Sustain Energy Rev, 12, 2265, 10.1016/j.rser.2007.05.001

Mardiana, 2012, Review on heat recovery technologies for building applications, Renew Sustain Energy Rev, 16, 1241, 10.1016/j.rser.2011.09.026

Zuo, 2014, Green building research-current status and future agenda: a review, Renew Sustain Energy Rev, 30, 271, 10.1016/j.rser.2013.10.021

Mihalakakou, 1992, Modelling the earth temperature using multiyear measurements, Energy Build, 19, 1, 10.1016/0378-7788(92)90031-B

Mihalakakou, 2003, On the heating potential of a single buried pipe using deterministic and intelligent techniques, Renew Energy, 28, 917, 10.1016/S0960-1481(02)00183-0

Chandrasekharam D, Chandrasekhar V. Geothermal energy resources, India: Country update. In: Proceedings of the World Geothermal Congress 2010, Bali, Indonesia, vol. 7; 2010. p.1–11.

Bansal, 1983, Performance of earth-air tunnel system, Energy Res, 7, 333, 10.1002/er.4440070405

Ozger, 2012, A review on the experimental and analytical analysis of earth to air heat exchanger (EAHE) systems in turkey, Renew Sustain Energy Rev, 15, 4483, 10.1016/j.rser.2011.07.103

Yang, 2010, Vertical-borehole ground-coupled heat pumps: a review of models and systems, Appl Energy, 87, 16, 10.1016/j.apenergy.2009.04.038

Florides, 2007, Ground heat exchangers – a review of systems, models and applications, Renew Energy, 32, 2461, 10.1016/j.renene.2006.12.014

Gazes J, Mixson D. Geothermal heating and air conditioning system. U. S. Patent 4 920 757, May 1, 1990.

Wiggs BR. Direct exchange geothermal heating/cooling system sub-surface tubing installation with supplemental sub-surface tubing configuration. U. S. Patent 7 856 839, Dec 28, 2010.

Omer, 2008, Ground-source heat pumps system and applications, Renew Sustain Energy Rev, 12, 344, 10.1016/j.rser.2006.10.003

Anandarajah, 2003, Mechanism controlling permeability changes in clays due to changes in pore fluids, J Geotech Geoenviron Eng, 129, 163, 10.1061/(ASCE)1090-0241(2003)129:2(163)

Omer, 2013, Review-Direct expansion ground source heat pumps for heating and cooling, Int Res J Eng, 1, 27

Bojic, 1999, Energy from two-pipe, earth-to-air heat exchanger, Energy, 24, 519, 10.1016/S0360-5442(99)00012-2

Peretti, 2013, The design and environment evaluation of earth-to-air heat exchangers (EAHE): a review, Renew Sustain Energy Rev, 28, 107, 10.1016/j.rser.2013.07.057

Bisoniya TS, Kumar A, Baredar P. Study on calculation models of earth-air heat exchanger systems. J Energy 2014;2014:1-15.

Ajmi, 2006, The cooling potential of earth–air heat exchanger for domestic buildings in a desert climate, Build Environ, 41, 235, 10.1016/j.buildenv.2005.01.027

Petrov, 1997, Selected factors influencing GCL hydraulic conductivity, J Geotech Geoenviron Eng, 123, 683, 10.1061/(ASCE)1090-0241(1997)123:8(683)

Man, 2011, Feasibility study on novel hybrid ground coupled heat pump system with nocturnal cooling radiator for cooling load dominated buildings, Appl Energy, 88, 4160, 10.1016/j.apenergy.2011.04.035

Santamouris, 2013, Passive cooling dissipation techniques for building and other structures: The state of the art. Energy and buildings, 57, 74

Dirmi, 2013, Geothermal energy resources in Uttarakhand, India, J Indian Geophys, 17, 403

Scott NR, Parsons RA, Kochler TA. Analysis and performance of an earth–air heat exchanger, ASAE no. 65-840; 1965.

Chel, 2009, Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for New Delhi composite climate, Energy Build, 41, 56, 10.1016/j.enbuild.2008.07.006

Maerefat, 2010, Passive cooling of buildings by using earth to air heat exchanger and solar chimney, Renew Energy, 35, 2316, 10.1016/j.renene.2010.03.003

Misra, 2013, Evaluating thermal performance and energy conservation potential of hybrid earth air tunnel heat exchanger in hot and dry climate-In situ measurement, J Therm Sci Eng Appl, 5, 1, 10.1115/1.4023435

Bansal, 2009, Performance analysis of earth–pipe–air heat exchanger for winter heating, Energy Build, 41, 1151, 10.1016/j.enbuild.2009.05.010

Bansal, 2010, Performance analysis of earth–pipe–air heat exchanger for summer cooling, Energy Build, 42, 645, 10.1016/j.enbuild.2009.11.001

Abbaspour-Fard, 2011, Evaluation of an earth-to-air heat exchanger for north–east of Iran with semi-arid climate, Int J Green Energy, 8, 499, 10.1080/15435075.2011.576289

Mogharreb, 2014, The effect of greenhouse vegetation coverage and area on the performance of an earth-to-air heat exchanger for heating and cooling mode, Int J Sustain Eng, 7, 245, 10.1080/19397038.2013.811559

Mongkon, 2013, Cooling performance and condensation evaluation of horizontal earth tube system for tropical greenhouse, Energy Build, 66, 104, 10.1016/j.enbuild.2013.07.009

Ascion, 2011, Earth-to-air heat exchanger for Italian climates, Renew Energy, 36, 2177, 10.1016/j.renene.2011.01.013

Balghouthi, 2005, Experimental investigation of thermal and moisture behavior of wet and dry soils with buried capillary heating system, Sol energy, 79, 669, 10.1016/j.solener.2005.06.011

Li, 2009, Experimental study of a ground sink direct cooling system in cold areas, Energy Build, 41, 1233, 10.1016/j.enbuild.2009.07.020

Goswami DY, Biseli KM. Use of Underground Air Tunnels for Heating and Cooling Agricultural and Residential Building, University of Florida, Fact Sheet EES 78; 1993.

Bisoniya, 2014, Cooling potential evaluation of earth–air heat exchanger system for summer season, Int J Eng Tech Res, 2, 309

Dubey, 2013, Earth air heat exchanger in parallel connection, Int J Eng Trends Technol, 4, 2463

Woodson, 2012, Earth–air heat exchangers for passive air conditioning: case study Burkina Faso, J Constr Dev Ctry, 17, 21

Rodrigues, 2013, A novel low-carbon space conditioning system incorporating phase-change materials and earth–air heat exchangers, Int J Low-Carbon Technol

Misra, 2012, Thermal performance investigation of hybrid earth air tunnel heat exchanger, Energy Build, 49, 531, 10.1016/j.enbuild.2012.02.049

Haghighi, 2014, Design guideline for application of earth-to-air heat exchanger coupled with solar chimney as a natural heating system, Int J Low-Carbon Technol

Tavakolinia, 2011

Ralegaonkar, 2014, Design and development of geothermal cooling system for composite climate zone in India, J Inst Eng (India): A, 95, 179

Chel, 2010, Stand alone photovoltaic (PV) integrated with earth to air heat exchanger (EAHE) for space heating cooling of adobe house in New Delhi (India), Energy Conserv Manag, 51, 393, 10.1016/j.enconman.2009.10.001

Shukla, 2008, Thermal performance of an adobe structure integrated with an earth–air heat exchanger: an experimental study, Agric Eng Int: CIGR J, 10, 1

Sodha, 1990, Effect of different earth surface treatments on the thermal performance of a room coupled to an earth–air tunnel, Int J Energy Res, 14, 337, 10.1002/er.4440140309

Yassine, 2014, Effectiveness of the earth tube heat exchanger system coupled to a space model in achieving thermal comfort in rural areas, Int J Sustain Energy, 33, 567, 10.1080/14786451.2012.762776

Choudhury, 2014, Minimizing changing climate impact on building using easily and economically feasible earth to air exchanger technique, Mitig Adapt Strateg Global Change, 19, 947, 10.1007/s11027-013-9453-3

Kabashnikov, 2002, Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems, Int J Heat Mass Transf, 45, 2407, 10.1016/S0017-9310(01)00319-2

Freire, 2013, Compact buried pipes system analysis for indoor air conditioning, Appl Therm Eng, 51, 1124, 10.1016/j.applthermaleng.2012.09.045

Sehli, 2012, Mohammed Tamali. The potential earth–air heat exchangers for low energy cooling of buildings in South Algeria, Energy Procedia, 18, 496, 10.1016/j.egypro.2012.05.061

Singh, 1994, Optimisation of earth–air tunnel system for space cooling, Energy Convers Manag, 35, 721, 10.1016/0196-8904(94)90057-4

Sethi, 2007, Thermal modeling of a greenhouse integrated to an aquifer coupled cavity flow heat exchanger system, Sol Energy, 36, 723, 10.1016/j.solener.2006.10.002

Ghosal, 2005, Modeling and comparative thermal performance of ground air collector and earth heat exchanger for heating of greenhouse, Energy Build, 37, 613, 10.1016/j.enbuild.2004.09.004

Ghosal, 2005, Parametric studies for heating performance of an earth to air heat exchanger coupled with a greenhouse, Int J Energy Res, 29, 991, 10.1002/er.1106

Shukla, 2006, Parametric and experimental study on thermal performance of an earth–air heat exchanger, Int J Energy Res, 30, 365, 10.1002/er.1154

Bansal, 2009, Performance enhancement of earth air tunnel heat exchanger using evaporative cooling, Int J Low-Carbon Technol, 00, 1

Tittelein, 2009, Modeling earth-to-air heat exchanger behavior with the convolutive response factors method, Appl Energy, 86, 1683, 10.1016/j.apenergy.2009.02.010

Pfafferott, 2003, Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency, Energy and Build, 35, 971, 10.1016/S0378-7788(03)00055-0

Trzaski, 2011, The influence of environmental and geometrical factors on air-ground tube heat exchanger energy efficiency, Build Environ, 46, 1436, 10.1016/j.buildenv.2011.01.010

Kumar, 2006, Heating and cooling potential of an earth-to-air heat exchanger using artificial neutral network, Renew Energy, 31, 1139, 10.1016/j.renene.2005.06.007

Bhutta, 2012, CFD applications in various heat exchangers design: a review, Appl Therm Eng, 32, 1, 10.1016/j.applthermaleng.2011.09.001

Wu, 2007, Modeling and evaluation of cooling capacity of earth-air-pipe systems, Energy Convers Manag, 48, 1462, 10.1016/j.enconman.2006.12.021

Breesch, 2005, Janssens. Passive cooling in a low-energy office building, Sol Energy, 79, 682, 10.1016/j.solener.2004.12.002

Khalajzadeh, 2012, A novel integrated system of ground heat exchanger and indirect evaporative cooler, Energy Build, 49, 604, 10.1016/j.enbuild.2012.03.009

Bansal, 2012, Performance analysis of integrated earth-air-tunnel-evaporative cooling system in hot and dry climate, Energy Build, 47, 525, 10.1016/j.enbuild.2011.12.024

Bansal, 2012, Performance evaluation and economic analysis of integrated earth-air-tunnel heat exchanger-evaporative cooling system, Energy Build, 55, 102, 10.1016/j.enbuild.2012.08.047

Bansal, 2013, Derating factor for evaluating thermal performance of earth tunnel air heat exchanger: a transient CFD analysis, Appl Energy, 102, 418, 10.1016/j.apenergy.2012.07.027

Bansal, 2013, Transient effect of soil thermal conductivity and duration of operation on performance of earth air tunnel heat exchanger, Appl Energy, 103, 1, 10.1016/j.apenergy.2012.10.014

Lund, 2003, Geothermal heat pumps - a world overview, Renewable Energy World, 6, 218

Lund JW, Freeston DH, Body TL. Direct utilization of geothermal energy 2010 worldwide review. In: Proceedings of the World Geothermal Congress 2010, Bali, Indonesia, vol. 7; 2010. p. 1–23.

Curtis R, Lund J, Sanner B, Rybach L, Hellstorm G. Ground source heat pumps-geothermal energy for anyone, anywhere: Current worldwide activity. In: Proceedings of the World Geothermal Congress 2005, Antalya, Turkey; 2005. p. 1437.

Gamage, 2014, The current technological status of ground source heat pump systems and their potential use in Northern Cyprus, Int J Wind Renew Energy, 3, 39

Sanner, 2003, Current status of ground source heat pumps and underground thermal energy storage in Europe, Geothermics, 32, 579, 10.1016/S0375-6505(03)00060-9

Sanner B. Current status of ground source heat pumps in Europe, Futurstock, Warsaw; 2003.

Lund, 2010, Direct utilization of geothermal energy, Energies, 03, 1443, 10.3390/en3081443

Younis, 2010, Ting DSK. Ground source heat pump system: current status, Int JEnviron Stud, 67, 405

Philappacopoulus, 2001, Influence of rebounding in ground heat exchangers used with geothermal heat pumps, Geothermics, 30, 527, 10.1016/S0375-6505(01)00011-6

Permchart, 2009, Study on using the ground as a heat sink for a 12,000-Btu/h modified air conditioner, World Acad Sci Eng Technol, 3, 15

Said, 2010, Feasibility of using ground-coupled condensers in A/C systems, Geothermics, 39, 201, 10.1016/j.geothermics.2010.02.001

Pahud, 2001, Comparison of thermal performance of double U-pipe borehole heat exchangers measured in situ, Energy Build, 33, 503, 10.1016/S0378-7788(00)00106-7

Wang, 2009, An experimental study of a direct expansion ground-coupled heat pump system in heating mode, Int J Energy Res, 33, 1367, 10.1002/er.1541

Luo, 2015, Heating and cooling performance analysis of a ground source heat pump system in Southern Germany, Geothermics, 53, 57, 10.1016/j.geothermics.2014.04.004

Ozgener, 2005, Experimental investigation of the performance of a solar-assisted ground-source heat pump system for greenhouse heating, Int J Energy Res, 29, 217, 10.1002/er.1049

Momin, 2013, Experimental investigation of geothermal air conditioning, Am J Eng Res, 2, 157

Kalema, 1985, The energy saving obtainable with solar heating and heat pumps in a northern climate, Int J Energy Res, 9, 403, 10.1002/er.4440090404

Svec, 1983, Palmer JHL. Heat transfer characteristics of in-ground heat exchangers, Int J Energy Res, 7, 265, 10.1002/er.4440070307

Svec, 1989, Palmer JHL. Performance of a spiral ground heat exchanger for heat pump application, Int J Energy Res, 13, 503, 10.1002/er.4440130502

Kara, 2007, Experimental performance evaluation of a closed-loop vertical ground source heat pump in the heating mode using energy analysis method, Int J Energy Res, 31, 1504, 10.1002/er.1316

Kujawa, 2003, Heat-flow characteristics of one-hole and two-hole systems for winning geothermal heat, Appl Energy, 74, 21, 10.1016/S0306-2619(02)00127-7

Magraner, 2010, Comparison between design and actual energy performance of a HVAC-ground coupled heat pump system in cooling and heating operation, Energy Build, 42, 1394, 10.1016/j.enbuild.2010.03.008

Cocchi, 2013, Modeling of an air conditioning system with geothermal heat pump for a residential building, Math Probl Eng, 2013, 1, 10.1155/2013/781231

Zheng, 2011, A study on the thermal performance of vertical U-tube ground heat exchanger, Energy Procedia, 12, 906, 10.1016/j.egypro.2011.10.119

Congedo, 2012, CFD simulations of horizontal ground heat exchangers: a comparison among different configurations, Appl Therm Eng, 33-34, 24, 10.1016/j.applthermaleng.2011.09.005

Zeng, 2003, Heat transfer analysis of boreholes in vertical ground heat exchangers, Int J Heat Mass Transf, 46, 4467, 10.1016/S0017-9310(03)00270-9

He, 2011, Simulation of a domestic ground source using a three-dimensional numerical borehole heat exchanger model, J Build Perform Simul, 4, 141, 10.1080/19401493.2010.513739

Perez-lombard, 2008, A review on buildings energy consumption information, Energy Build, 40, 394, 10.1016/j.enbuild.2007.03.007

Wan, 2011, Future trends of building heating and cooling loads and energy consumption in different climates, Build Environ, 46, 223, 10.1016/j.buildenv.2010.07.016

Zhou, 2007, Performance of energy recovery ventilator with various weathers and temperature set-points, Energy Build, 39, 1202, 10.1016/j.enbuild.2006.12.010

Karytsas, 2012, Current state of geothermal heat pumps as applied to buildings, Adv Build Energy Res, 6, 119, 10.1080/17512549.2012.672004