A novel accelerated fatigue testing system for pulsatile applications of cardiac devices using widely translatable cam and linkage-based mechanisms

Medical Engineering & Physics - Tập 109 - Trang 103896 - 2022
Matthew H. Park1,2, Annabel M. Imbrie-Moore1,2, Yuanjia Zhu1,3, Mark Sellke4, Mateo Marin-Cuartas1,5, Robert J. Wilkerson1, Y. Joseph Woo1,3
1Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, United States
2Department of Mechanical Engineering, Stanford University, Stanford, CA, United States
3Department of Bioengineering, Stanford University, Stanford, CA, United States
4Department of Mathematics, Stanford University, Stanford, CA, United States
5University Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany

Tài liệu tham khảo

“Test to Success & ASTM F3211 Fatigue to Fracture | Element” [Online]. Available: https://www.element.com/nucleus/2020/04/17/18/59/astm-f3211-fatigue-to-fracture. [Accessed: 07-Dec-2020]. Jimenez, 2018, Accelerated fatigue test in mechanical components Zeng, 2019, Research on high-frequency small-load fatigue testing device driven by piezoelectric actuator, Rev Sci Instrum, 90, 10.1063/1.5085851 Son, 2011, Optimal design to increase thrust force in electro-magnetic linear actuator for fatigue and durability test machine, IEEE Trans Magn, 47, 4294, 10.1109/TMAG.2011.2151182 Imbrie-Moore, 2020, Artificial papillary muscle device for off-pump transapical mitral valve repair, J Thorac Cardiovasc Surg Mirnajafi, 2010, Effects of cyclic flexural fatigue on porcine bioprosthetic heart valve heterograft biomaterials, J Biomed Mater Res A, 94, 205, 10.1002/jbm.a.32659 Sacks, 2001, The biomechanical effects of fatigue on the porcine bioprosthetic heart valve, J Long Term Eff Med Implants, 11, 17, 10.1615/JLongTermEffMedImplants.v11.i34.100 Sacks, 2009, On the biomechanics of heart valve function, J Biomech, 42, 1804, 10.1016/j.jbiomech.2009.05.015 Jimenez, 2003, Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: an in vitro study, Ann Biomed Eng, 31, 1171, 10.1114/1.1616929 He, 2009, A novel method to measure mitral valve chordal tension, J Biomech Eng, 131, 10.1115/1.3005160 Padala, 2010, Mechanics of the mitral valve strut chordae insertion region, J Biomech Eng, 132, 10.1115/1.4001682 Jimenez, 2004, Mechanics of the mitral valve: in vitro studies, Conf Proc IEEE Eng Med Biol Soc, 3727 Seeburger, 2014, Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the TACT trial (Transapical artificial chordae tendinae) proof of concept, J Am Coll Cardiol, 63, 914, 10.1016/j.jacc.2013.07.090 Colli, 2015, Transapical off-pump mitral valve repair with neochord implantation (TOP-MINI): step-by-step guide, Ann Cardiothorac Surg, 4, 295 Kiefer, 2018, Good 5-year durability of transapical beating heart off-pump mitral valve repair with neochordae, Ann Thorac Surg, 106, 440, 10.1016/j.athoracsur.2018.01.092 Gammie, 2016, Transapical beating-heart mitral valve repair with an expanded polytetrafluoroethylene cordal implantation device: initial clinical experience, Circulation, 134, 189, 10.1161/CIRCULATIONAHA.116.022010 Fiocco, 2019, Transcatheter mitral valve chordal repair: current indications and future perspectives, Front Cardiovasc Med, 6, 128, 10.3389/fcvm.2019.00128 Imbrie-Moore, 2019, Ex vivo biomechanical study of apical versus papillary neochord anchoring for mitral regurgitation, Ann Thorac Surg, 108, 90, 10.1016/j.athoracsur.2019.01.053 Padala, 2014, Impact of mitral valve geometry on hemodynamic efficacy of surgical repair in secondary mitral regurgitation, J Heart Valve Dis, 23, 79 Vergnat, 2011, Saddle-shape annuloplasty increases mitral leaflet coaptation after repair for flail posterior leaflet, Ann Thorac Surg, 92, 797, 10.1016/j.athoracsur.2011.04.047 Spinner, 2012, The effects of a three-dimensional, saddle-shaped annulus on anterior and posterior leaflet stretch and regurgitation of the tricuspid valve, Ann Biomed Eng, 40, 996, 10.1007/s10439-011-0471-6 Jensen, 2011, Saddle-shaped mitral valve annuloplasty rings improve leaflet coaptation geometry, J Thorac Cardiovasc Surg, 142, 697, 10.1016/j.jtcvs.2011.01.022 Jensen, 2008, Saddle-shaped mitral valve annuloplasty rings experience lower forces compared with flat rings, Circulation, 118, S250 Padala, 2009, Saddle shape of the mitral annulus reduces systolic strains on the P2 segment of the posterior mitral leaflet, Ann Thorac Surg, 88, 1499, 10.1016/j.athoracsur.2009.06.042 Jimenez, 2007, A saddle-shaped annulus reduces systolic strain on the central region of the mitral valve anterior leaflet, J Thorac Cardiovasc Surg, 134, 1562, 10.1016/j.jtcvs.2007.08.037 Ranganathan, 1970, Morphology of the human mitral valve, Circulation, 41, 459, 10.1161/01.CIR.41.3.459 Lam, 1970, Morphology of the human mitral valve. I. Chordae tendineae: a new classification, Circulation, 41, 449, 10.1161/01.CIR.41.3.449