Exergetic assessment of EAHEs for building heating in Turkey: A greenhouse case study

Energy Policy - Tập 38 Số 9 - Trang 5141-5150 - 2010
Önder Özgener1, Leyla Özgener2
1Solar Energy Institute, Ege University, Bornova, Izmir, Turkey
2Department of Mechanical Engineering, Faculty of Engineering, Celal Bayar University, Muradiye, Manisa, Turkey

Tóm tắt

Từ khóa


Tài liệu tham khảo

Alcorn, J., 1995. Embodied energy coefficients of building materials. Center for Building. Performance Research, Victoria University of Wellington.

Anon, 2003. Greenhouse heating requirements 〈www.cps.gov.on.ca〉.

Badescu, 2007, Economic aspects of using ground thermal energy for passive house heating, Renewable Energy, 32, 895, 10.1016/j.renene.2006.04.006

Chel, 2009, Building integrated renewable energy technologies: embodied energy, economic analysis and potential of CO2 emission mitigation, 209

Cucumo, 2008, A one-dimensional transient analytical model for earth-to-air heat exchangers, taking into account condensation phenomena and thermal perturbation from the upper free surface as well as around the buried pipes, International Journal of Heat and Mass Transfer, 51, 506, 10.1016/j.ijheatmasstransfer.2007.05.006

Dincer, 2004, A new model for thermodynamic analysis of a drying process, International Journal of Heat and Mass Transfer, 47, 645, 10.1016/j.ijheatmasstransfer.2003.08.013

Dincer, 2002, The role of exergy in energy policy making, Energy Policy, 30, 137, 10.1016/S0301-4215(01)00079-9

Esin, 2009, Suggestions for increasing energy efficiency in exşsting building, Turkey example, 369

Gaggioli, 1998, Available energy and exergy, International Journal of Applied Thermodynamics, 1, 1

Ghosal, 2006, Modeling and parametric studies for thermal performance of an earth to air heat exchanger integrated with a greenhouse, Energy Conversion and Management, 47, 1779, 10.1016/j.enconman.2005.10.001

Ghosal, 2004, Thermal modeling of a greenhouse with an integrated earth to air heat exchanger: an experimental validation, Energy and Buildings, 36, 219, 10.1016/j.enbuild.2003.10.006

Goswami, 1985, Heat transfer analysis in environmental control using an underground air tunnel, Journal of Solar Energy Engineering, 107, 141, 10.1115/1.3267667

Goswami, 1990, Performance analysis of a closed loop climate control system using underground air tunnel, Journal of Solar Energy Engineering, 112, 76, 10.1115/1.2929650

Hübner, 2001, Mieter im Passivhaus—Nutzungsorientierte Gestaltung als Voraussetzung fünachhaltiges Wohnen, 137

Kotas, 1985

Krakow, 1991, Exergy analysis: dead-state definition, ASHRAE Transactions, 97, 328

Mihalakakou, 1994, On the cooling potential of earth to air heat exchangers, Energy Conversion and Management, 35, 395, 10.1016/0196-8904(94)90098-1

Moran, 1982

Moran, 1999, Engineering Thermodynamics

N.N., Directive 2002/91/EC, 2002.

Ozgener, 2004, Thermo-mechanical exergy analysis of Balcova Geothermal District Heating system in Izmir, Turkey, ASME—Journal of Energy Resources Technology, 126, 293, 10.1115/1.1805540

Ozgener, 2009, Monitoring of energy exergy efficiencies and exergoeconomic parameters of Geothermal District Heating Systems (GDHSs), Applied Energy, 86, 1704, 10.1016/j.apenergy.2008.11.017

Ozgener, O., Ozgener, L., Goswami, D.Y., 2009. Utilization of earth air heat exchangers for solar greenhouses pre heating and performance analysis. Project No.: 09GEE003, Supported by Ege University Research Fund, continuing project.

Ozgener, 2010, Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings, Energy, 35, 262, 10.1016/j.energy.2009.09.018

Ozgener, 2005, Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system, Energy and Buildings, 37, 101, 10.1016/j.enbuild.2004.06.003

Ozgener, O., Ozgener, L., 2010. Exergoeconomic analysis of an underground air tunnel system for greenhouse cooling system. International Journal of Refrigeration, doi:10.1016/j.irefrig.2010.02.008

Pfafferott, 2003, Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency, Energy and Buildings, 35, 971, 10.1016/S0378-7788(03)00055-0

Rosen, 2003, Exergy–cost–energy–mass analysis of thermal systems and processes, Energy Conversion and Management, 4, 1633, 10.1016/S0196-8904(02)00179-6

Santamouris, 1995, On the performance of buildings coupled with earth to air heat exchangers, Solar Energy, 54, 375, 10.1016/0038-092X(95)00016-K

Shukla, 2006, Thermal modeling for greenhouse heating by using thermal curtain and an earth–air heat exchanger, Building and Environment, 41, 843, 10.1016/j.buildenv.2005.04.014

Szargut, 1998

Thormark, 2002, A low energy building in a life cycle—its embodied energy, energy need for operation and recycling potential, Building and Environment, 37, 429, 10.1016/S0360-1323(01)00033-6

Utrick, J.B. 2009. Energy and buildings efficiency, air quality, and conservation. Nova Publishers, Inc., USA.

Zhang, 2009, Convective heat transfer prediction in large rectangular cross-sectional area earth-to-air heat, Exchangers Building and Environment, 44, 1892, 10.1016/j.buildenv.2009.01.011

Zogou, 2009, Application of building energy simulation in sizing and design of an office building and its HVAC equipment, 279