Quantitative Interpretation of Magnetization Transfer in Spoiled Gradient Echo MRI Sequences

Elsevier BV - Tập 145 Số 1 - Trang 24-36 - 2000
John G John G, G.Bruce G.Bruce

Tài liệu tham khảo

Wolff, 1989, Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo, Magn. Reson. Med., 10, 135, 10.1002/mrm.1910100113 Wolff, 1991, Magnetization transfer contrast: Method for improving contrast in gradient-recalled-echo images, Radiology, 179, 133, 10.1148/radiology.179.1.2006263 Ordidge, 1991, Magnetization transfer contrast (MTC) in flash MR imaging, Magn. Reson. Imaging, 9, 889, 10.1016/0730-725X(91)90532-Q Hajnal, 1992, Design and implementation of magnetization transfer pulse sequences for clinical use, J. Comput. Assist. Tomogr., 16, 7, 10.1097/00004728-199201000-00003 Pike, 1992, Magnetization transfer time-of-flight magnetic resonance angiography, Magn. Reson. Med., 25, 372, 10.1002/mrm.1910250217 Berry, 1999, A multicenter measurement of magnetization transfer ratio in normal white matter, J. Magn. Reson. Imaging, 9, 441, 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO;2-R Eng, 1991, Quantitative 1H magnetization transfer imaging in vivo, Magn. Reson. Med., 17, 304, 10.1002/mrm.1910170203 Yeung, 1994, Transient decay of longitudinal magnetization in hetrogeneous spin systems under selective saturation. IV. Reformulation of the spin-bath-model equations by the Redfield–Provotorov theory, J. Magn. Reson. A, 106, 37, 10.1006/jmra.1994.1004 Morrison, 1995, Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir, J. Magn. Reson. B, 108, 103, 10.1006/jmrb.1995.1111 Edzes, 1977, Cross relaxation and spin diffusion in the proton NMR of hydrated collagen, Nature, 265, 521, 10.1038/265521a0 Edzes, 1978, The measurement of cross-relaxation effects in the proton NMR spin–lattice relaxation of water in biological systems: Hydrated collagen and muscle, J. Magn. Reson., 31, 207 Hoffman, 1966, Transient and steady-state Overhauser experiments in the investigation of relaxation processes. Analogies between chemical exchange and relaxation, J. Chem. Phys., 45, 10.1063/1.1727890 Quesson, 1997, Magnetization transfer imaging in vivo of the rat brain at 4.7 T: Interpretation using a binary spin-bath model with a superlorentzian lineshape, Magn. Reson. Med., 38, 974, 10.1002/mrm.1910380617 Quesson, 1998, Magnetization transfer imaging of rat brain under non-steady-state conditions. Contrast prediction using a binary spin-bath model and a super-Lorentzian lineshape, J. Magn. Reson., 130, 321, 10.1006/jmre.1997.1326 Henkelman, 1993, Quantitative interpretation of magnetization transfer, Magn. Reson. Med., 29, 759, 10.1002/mrm.1910290607 Lee, 1997, Low power method for estimating the magnetization transfer bound-pool macromolecular fraction, J. Magn. Reson. Imaging, 7, 913, 10.1002/jmri.1880070521 Chai, 1996, Estimation of in vivo proton intrinsic and cross-relaxation rate in human brain, Magn. Reson. Med., 36, 147, 10.1002/mrm.1910360123 Gochberg, 1999, Quantitative imaging of magnetization transfer using multiple selective pulses, Magn. Reson. Med., 41, 1065, 10.1002/(SICI)1522-2594(199905)41:5<1065::AID-MRM27>3.0.CO;2-9 Goldman, 1970 Listerud, 1997, Off-resonance pulsed magnetization transfer in clinical mr imaging: Optimization by an analysis of transients, Magn. Reson. Med., 37, 693, 10.1002/mrm.1910370511 Li, 1997, A flexible magnetization transfer line shape derived from tissue experimental data, Magn. Reson. Med., 37, 866, 10.1002/mrm.1910370610 Graham, 1996, Quantifying the magnetization transfer produced by RF irradiation with multiple frequency components Graham, 1997, Understanding pulsed magnetization transfer, J. Magn. Reson. Imaging, 7, 903, 10.1002/jmri.1880070520 Bodenhausen, 1984, Selection of coherence-transfer pathways in NMR pulse experiments, J. Magn. Reson., 58, 370 Pike, 1996, Pulsed magnetization transfer contrast in gradient echo imaging: A two-pool analytic description of signal response, Magn. Reson. Med., 36, 95, 10.1002/mrm.1910360117 Zur, 1991, Spoiling of transverse magnetization in steady-state sequences, Magn. Reson. Med., 21, 251, 10.1002/mrm.1910210210 Swanson, 1991, Broadband excitation and detection of cross-relaxation NMR spectra, J. Magn. Reson., 95, 615 Sled, 1998, Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI, IEEE Trans. Med. Imaging, 17, 653, 10.1109/42.730409 Sled, 1998, A non-parametric method for automatic correction of intensity non-uniformity in MRI data, IEEE Trans. Med. Imaging, 17, 87, 10.1109/42.668698 Glover, 1991, Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction, Magn. Reson. Med., 18, 371, 10.1002/mrm.1910180211 Topp, 1997, Fast multislice B1-mapping Caines, 1991, Incorporation of magnetization transfer into the formalism for rotating-frame spin–lattice NMR relaxation in the presence of an off-resonance-irradiation field, J. Magn. Reson., 95, 558 Poon, 1992, Practical T2 quantitation for clinical applications, J. Magn. Reson. Imaging, 2, 541, 10.1002/jmri.1880020512 Borowiak, 1989 Bates, 1988 Iino, 1994, Transition from Lorentzian to Gaussian line shape of magnetization transfer spectrum in bovine serum albumin solutions, Magn. Reson. Med., 32, 459, 10.1002/mrm.1910320406 Morrison, 1995, A model for magnetization transfer in tissues, Magn. Reson. Med., 33, 475, 10.1002/mrm.1910330404 Harrison, 1995, Magnetization transfer and T2 relaxation components in tissue, Magn. Reson. Med., 33, 490, 10.1002/mrm.1910330406 Stanisz, 1999, Characterizing white matter with magnetization transfer and T2, Magn. Reson. Med., 42, 1128, 10.1002/(SICI)1522-2594(199912)42:6<1128::AID-MRM18>3.0.CO;2-9 MacKay, 1994, In vivo visualization of myelin water in brain by magnetic resonance, Magn. Reson. Med., 31, 673, 10.1002/mrm.1910310614 Wu, 1994, Effects of transverse cross relaxation on magnetization transfer, J. Magn. Reson. B, 105, 73, 10.1006/jmrb.1994.1103