Cardiac-induced physiologic noise in tissue is a direct observation of cardiac-induced fluctuations

Magnetic Resonance Imaging - Tập 22 - Trang 9-13 - 2004
Pallab K. Bhattacharyya1, Mark J. Lowe2
1Department of Radiology, Indiana University School of Medicine, Indianapolis, IN 46202, USA
2Division of Radiology, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA

Tài liệu tham khảo

Jezzard P, LeBihan D, Cuenod D, Pannier L, Prinster A, Turner R. An investigation of the contribution of physiologic noise in human functional MRI studies at 1.5 Tesla and 4 Tesla. Proceedings of the 12th Annual Meeting of the Society of Magnetic Resonance in Medicine, New York, 1993, p.1392 Weisskoff RM, Baker J, Belliveau J, et al Power spectrum analysis of functionally-weighted MR data: What's in the noise? Proceedings of the 12th Annual Meeting of the Society of Magnetic Resonance in Medicine, New York, 1993, p.7 Dagli, 1999, Localization of cardiac-induced signal change in fMRI, Neuroimage, 9, 407, 10.1006/nimg.1998.0424 Biswal, 1996, Reduction of physiological fluctuations in fMRI using digital filters, Magn Reson Med, 35, 107, 10.1002/mrm.1910350114 Biswal, 1995, Functional connectivity in the motor cortex of resting human brain using echo-planar MRI, Magn Reson Med, 34, 537, 10.1002/mrm.1910340409 Lowe, 1998, Functional connectivity in single and multi-slice echoplanar imaging using resting-state fluctuations, Neuroimage, 7, 119, 10.1006/nimg.1997.0315 Lowe, 1999, Gram-Schmidt orthogonalization to reduce aliased physiologic noise in low sampling rate fMRI data, NeuroImage, 9, S230 Lund TE, Hanson LG. Physiological noise reduction in fMRI using vessel time-series as covariates in a general linear model. Proceedings of the 9th Annual Meeting of the International Society of Magnetic Resonance in Medicine, Glasgow, Scotland, 2001. p 22 Lund, 2001, FcMRI—mapping functional connectivity or correlating cardiac-induced noise?, Magn Reson Med, 46, 628, 10.1002/mrm.1238 Zhao, 2000, B0 fluctuation-induced temporal variation in EPI image series due to the disturbance of steady-state free precession, Magn Reson Med, 44, 758, 10.1002/1522-2594(200011)44:5<758::AID-MRM14>3.0.CO;2-G Li, 2001, Reducing cardiac noise in BOLD-weighted voxel time courses in an fMRI dataset by increasing TR and/or applying a crusher gradient in an EPI acquisition pulse, Magn Reson Med, 46, 629, 10.1002/mrm.1239 Li, 2000, Cocaine administration decreases functional connectivity in human primary visual and motor cortex as detected by functional MRI, Magn Reson Med, 43, 45, 10.1002/(SICI)1522-2594(200001)43:1<45::AID-MRM6>3.0.CO;2-0 Wu, 1990, Effect of diffusion on the steady-state magnetization with pulsed field gradients, J Magn Reson, 90, 243 Stainsby JA, Yu JM, Foltz WD, Wright GA. Monitoring blood oxygenation in a microcirculation model. Proceedings of the 4th Scientific Meeting of the International Society of Magnetic Resonance in Medicine, 1996, p. 1312