Biomechanical Behavior of a New Nucleus Prosthesis Made of Knitted Titanium Filaments

SAS Journal - Tập 1 - Trang 125-130 - 2007
Annette Kettler1, Hans-Peter Kaps2, Bodo Haegele1, Hans-Joachim Wilke1
1Institute for Orthopaedic Research and Biomechanics, University of Ulm, Germany
2The Department of Orthopaedics, BG Trauma-Centre, Tuebingen, Germany

Tài liệu tham khảo

Anderson, 2004, Intervertebral disc arthroplasty, Spine, 29, 2779, 10.1097/01.brs.0000146460.11591.8a Grob, 2005, Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years, Spine, 30, 324, 10.1097/01.brs.0000152584.46266.25 Wilke, 2006, Biomechanical evaluation of a new total posterior-element replacement system, Spine, 31, 2790, 10.1097/01.brs.0000245872.45554.c0 Di Martino, 2005, Nucleus pulposus replacement: basic science and indications for clinical use, Spine, 30, S16, 10.1097/01.brs.0000174530.88585.32 Bertagnoli, 2002, Surgical and clinical results with the PDN prosthetic disc–nucleus device, Eur Spine J, 11, S143, 10.1007/s00586-002-0424-8 Schonmayr, 2002, The PDN disc nucleus prosthesis: experiences, technical considerations, and clinical results 5 years after the first implantation, 283 Allen, 2004, Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus, Spine, 29, 515, 10.1097/01.BRS.0000113871.67305.38 Wilke, 2006, Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model?, Eur Spine J, 15, S433, 10.1007/s00586-006-0177-x Wilke, 1994, A universal spine tester for in vitro experiments with muscle force simulation, Eur Spine J, 3, 91, 10.1007/BF02221446 Wilke, 1999, New in vivo measurements of pressures in the intervertebral disc in daily life, Spine, 24, 755, 10.1097/00007632-199904150-00005 Wilke, 2001, Effect of a prosthetic disc nucleus on the mobility and disc height of the L4-5 intervertebral disc postnucleotomy, J Neurosurg, 95, 208 Joshi, 2006, Functional compressive mechanics of a PVA/PVP nucleus pulposus replacement, Biomaterials, 27, 176, 10.1016/j.biomaterials.2005.06.003 Korge, 2002, A spiral implant as nucleus prosthesis in the lumbar spine, Eur Spine J, 11, S149, 10.1007/s00586-002-0444-4 Wilke, 1998, Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants, Eur Spine J, 7, 148, 10.1007/s005860050045 Langrana, 1994, Materials and design concepts for an intervertebral disc spacer. I. fiber-reinforced composite design, J Appl Biomater, 5, 125, 10.1002/jab.770050205 Thomas, 2003, Novel associated hydrogels for nucleus pulposus replacement, J Biomed Mater Res, 67, 1329, 10.1002/jbm.a.10119 Cotterill, 1986, An anatomical comparison of the human and bovine thoracolumbar spine, J Orthop Res, 4, 298, 10.1002/jor.1100040306 Wilke, 1997, Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data, Eur Spine J, 6, 129, 10.1007/BF01358746