Serum cystatin C is superior to serum creatinine as a marker of kidney function: A meta-analysis
Tài liệu tham khảo
Bostom, 2000, Cystatin C measurement: Improved detection of mild decrements in glomerular filtration rate versus creatinine-based estimates?, Am J Kidney Dis, 36, 205, 10.1053/ajkd.2000.9199
Price, 2000, Developments in the assessment of glomerular filtration rate, Clin Chim Acta, 297, 55, 10.1016/S0009-8981(00)00233-3
Nilsson-Ehle, 1994, New markers for the determination of GFR: Iohexol clearance and cystatin C serum concentration, Kidney Int, 47, S17
Grubb, 2000, Cystatin C—Properties and use as diagnostic marker, Adv Clin Chem, 35, 63, 10.1016/S0065-2423(01)35015-1
Grubb, 1992, Diagnostic value of analysis of cystatin C and protein HC in biological fluids, Clin Nephrol, 38, S20
Grubb, 1985, Serum concentration of cystatin C, factor D and beta 2-microglobulin as a measure of glomerular filtration rate, Acta Med Scand, 218, 499, 10.1111/j.0954-6820.1985.tb08880.x
Simonsen, 1985, The blood serum concentration of cystatin C (gamma-trace) as a measure of the glomerular filtration rate, Scand J Clin Lab Invest, 45, 97, 10.3109/00365518509160980
Woitas, 2000, Correlation of serum concentrations of cystatin C and creatinine to inulin clearance in liver cirrhosis, Clin Chem, 46, 712, 10.1093/clinchem/46.5.712
Newman, 1995, Serum cystatin C measured by automated immunoassay: A more sensitive marker of changes in GFR than serum creatinine, Kidney Int, 47, 312, 10.1038/ki.1995.40
Risch, 1999, Rapid and accurate assessment of glomerular filtration rate in patients with renal transplants using serum cystatin C, Nephrol Dial Transplant, 14, 1991, 10.1093/ndt/14.8.1991
Harmoinen, 1999, Evaluation of plasma cystatin C as a marker for glomerular filtration rate in patients with type 2 diabetes, Clin Nephrol, 52, 363
Plebani, 1998, Is serum cystatin C a sensitive marker of glomerular filtration rate (GFR)? A preliminary study on renal transplant patients, Ren Fail, 20, 303, 10.3109/08860229809045115
Priem, 2001, Beta-trace protein is not better than cystatin C as an indicator of reduced glomerular filtration rate, Clin Chem, 47, 2181, 10.1093/clinchem/47.12.2181
Thomassen, 2001, Serum cystatin C as a marker of the renal function in patients with spinal cord injury, J Am Soc Nephrol, 12, 252A
Kyhse-Andersen, 1994, Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate, Clin Chem, 40, 1921, 10.1093/clinchem/40.10.1921
Donadio, 2001, beta 2-microglobulin, and retinol-binding protein as indicators of glomerular filtration rate: Comparison with plasma creatinine, J Pharm Biomed Anal, 24, 835, 10.1016/S0731-7085(00)00550-1
Coll, 2000, Serum cystatin C as a new marker for noninvasive estimation of glomerular filtration rate and as a marker for early renal impairment, Am J Kidney Dis, 36, 29, 10.1053/ajkd.2000.8237
Oddoze, 2001, Cystatin C is not more sensitive than creatinine for detecting early renal impairment in patients with diabetes, Am J Kidney Dis, 38, 310, 10.1053/ajkd.2001.26096
Stickle, 1998, Correlation of plasma concentrations of cystatin C and creatinine to inulin clearance in a pediatric population, Clin Chem, 44, 1334, 10.1093/clinchem/44.6.1334
van Essen, 1997, Serum cystatin C is not superior to creatinine based methods to estimate GFR during long term follow up, J Am Soc Nephrol, 8, 79A
Coll, 2001, In reply: Serum cystatin as a marker of glomerular filtration rate, Am J Kidney Dis, 37, 450, 10.1053/ajkd.2001.22606
Parvex, 2001, Is cystatin C a simple measure of glomerular filtration rate in children?, J Am Soc Nephrol, 12, 82A
Kazama, 1999, Serum cystatin C level indicates glomerular filtration rate with a better specificity to detect renal dysfunction than 24 hr CCr, J Am Soc Nephrol, 10, 170A
Puliyanda, 1999, Cystatin C as a marker of glomerular filtration in children, J Am Soc Nephrol, 10, 149A
Nakai, 1999, Practical use of cystatin C measurement as a sensitive and specific marker of GFR change, J Am Soc Nephrol, 10, 112A
Uzun, 2001, Serum cystatin C level in healthy adults and in patients with renal failure, J Am Soc Nephrol, 12, 87A
Zitta, 2001, Cystatin C concentration and glomerular filtration rate, Lancet, 357, 635, 10.1016/S0140-6736(05)71424-0
Ylinen, 1999, Cystatin C as a marker for glomerular filtration rate in pediatric patients, Pediatr Nephrol, 13, 506, 10.1007/s004670050647
Vinge, 1999, Relationships among serum cystatin C, serum creatinine, lean tissue mass and glomerular filtration rate in healthy adults, Scand J Clin Lab Invest, 59, 587, 10.1080/00365519950185076
Tian, 1997, Cystatin C measurement and its practical use in patients with various renal diseases, Clin Nephrol, 48, 104
Randers, 2000, Serum cystatin C as an endogenous parameter of the renal function in patients with normal to moderately impaired kidney function, Clin Nephrol, 54, 203
Randers, 1998, Serum cystatin C as a marker of the renal function, Scand J Clin Lab Invest, 58, 585, 10.1080/00365519850186210
Paskalev, 2001, Serum cystatin C in renal transplant patients, Clin Chim Acta, 310, 53, 10.1016/S0009-8981(01)00522-8
Page, 2000, Clinical value of cystatin C determination, Clin Chim Acta, 297, 67, 10.1016/S0009-8981(00)00234-5
Meier, 1999, Serum concentration of cystatin C as a rapid estimation of the renal function, J Am Soc Nephrol, 10, 82A
Le Bricon, 2000, Plasma cystatin C is superior to 24-h creatinine clearance and plasma creatinine for estimation of glomerular filtration rate 3 months after kidney transplantation, Clin Chem, 46, 1206, 10.1093/clinchem/46.8.1206
Le Bricon, 1999, Changes in plasma cystatin C after renal transplantation and acute rejection in adults, Clin Chem, 45, 2243, 10.1093/clinchem/45.12.2243
Jung, 1995, Cystatin C: A promising marker of glomerular filtration rate to replace creatinine, Nephron, 70, 370, 10.1159/000188621
Herget-Rosenthal, 2000, Cystatin C: Efficacy as screening test for reduced glomerular filtration rate, Am J Nephrol, 20, 97, 10.1159/000013564
Herget-Rosenthal, 2000, Cystatin C—An accurate marker of glomerular filtration rate after renal transplantation?, Transpl Int, 13, 285, 10.1111/j.1432-2277.2000.tb01083.x
Helin, 1998, Serum cystatin C as a determinant of glomerular filtration rate in children, Clin Nephrol, 49, 221
Fliser, 2001, Serum cystatin C concentration as a marker of renal dysfunction in the elderly, Am J Kidney Dis, 37, 79, 10.1053/ajkd.2001.20628
Filler, 1999, Diagnostic sensitivity of serum cystatin for impaired glomerular filtration rate, Pediatr Nephrol, 13, 501, 10.1007/s004670050646
Filler, 1997, Are cystatin C and beta 2-microglobulin better markers than serum creatinine for prediction of a normal glomerular filtration rate in pediatric subjects?, Clin Chem, 43, 1077, 10.1093/clinchem/43.6.1077
Erlandsen, 1999, Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System, Scand J Clin Lab Invest, 59, 1, 10.1080/00365519950185940
Demirtas, 2001, Diagnostic value of serum cystatin C for evaluation of hepatorenal syndrome, Clin Chim Acta, 311, 81, 10.1016/S0009-8981(01)00546-0
Chantrel, 2000, Comparison of cystatin C versus creatinine for detection of mild renal failure, Clin Nephrol, 54, 374
Bokenkamp, 1998, Cystatin C—A new marker of glomerular filtration rate in children independent of age and height, Pediatrics, 101, 875, 10.1542/peds.101.5.875
Greiner, 2000, Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests, Prev Vet Med, 45, 23, 10.1016/S0167-5877(00)00115-X
Farr, 2000, Diagnostic tests: Distinguishing good tests from bad and even ugly ones, Infect Control Hosp Epidemiol, 21, 278, 10.1086/501760
Zweig, 1993, Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine, Clin Chem, 39, 561, 10.1093/clinchem/39.4.561
Pergande, 1993, Sandwich enzyme immunoassay of cystatin C in serum with commercially available antibodies, Clin Chem, 39, 1885, 10.1093/clinchem/39.9.1885