‘Aussie normals’: an a priori study to develop clinical chemistry reference intervals in a healthy Australian population

Pathology - Tập 47 - Trang 138-144 - 2015
G. Koerbin1,2, J.A. Cavanaugh3, J.M. Potter4,5, W.P. Abhayaratna5, N.P. West6, N. Glasgow4, C. Hawkins4,5, D. Armbruster7, C. Oakman5, P.E. Hickman4,5
1NSW Health Pathology, United States
2University of Canberra, United States
3Australian National University Biological Sciences, United States
4Australian National University Medical School, United States
5ACT Pathology, United States
6Griffith University Australia; United States
7Abbott Diagnostics, United States

Tài liệu tham khảo

Schneider, 1960, Some thoughts on normal, or standard, values in clinical medicine, Pediatrics, 26, 973, 10.1542/peds.26.6.973 Horn, 2003, Reference intervals an update, Clin Chim Acta, 334, 5, 10.1016/S0009-8981(03)00133-5 Horn, 2010, Reference intervals and clinical decision limits, 439 Jones, 2008, Reference intervals, Clin Biochem Rev, 29, S93 2008 Katayev, 2010, Establishing reference intervals for clinical laboratory test results, Is there a better way?, 133, 180 Johnson, 2004, International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Plasma Proteins. Reference intervals for serum proteins: similarities and differences between adult Caucasian and Asian Indian males in Yorkshire, UK., Clin Chem Lab Med, 42, 792, 10.1515/CCLM.2004.132 Ichihara, 2008, Science Committee for the Asian-Pacific Federation of Clinical Biochemistry Sources of variation of commonly measured serum analytes in 6 Asian cities and consideration of common reference intervals, Clin Chem, 54, 356, 10.1373/clinchem.2007.091843 Larsson, 2013, Reference values for fasting insulin in 75 year old females and males, Clin Biochem, 46, 1125, 10.1016/j.clinbiochem.2013.03.024 Abhayaratna, 2006, Prevalence of heart failure and systolic ventricular dysfunction in older Australians: the Canberra Heart Study, MJA, 184, 151 2013 White, 2004, AACB Uncertainty of Measurement Working Group. Uncertainty of measurement in quantitative medical testing: a laboratory implementation guide, Clin Biochem Rev, 25, S1 Harris, 1990, On dividing reference data into subgroups to produce separate reference ranges, Clin Chem, 36, 265, 10.1093/clinchem/36.2.265 Westgard QC. Desirable biological variation database specifications. Cited 7 Oct 2014. http://www.westgard.com/biodatabase1.htm Berg, 2011, Pathology harmony a pragmatic and scientific approach to unfounded variation in the clinical laboratory, Ann Clin Biochem, 48, 195, 10.1258/acb.2011.011078 Australian Bureau of Statistics. Census Data 2006. Cited 2 Jun 2013. http://www.censusdata.abs.gov.au Australian Bureau of Statistics. Profiles of Health, Australia, 2011-13: Overweight and obesity. Cited 7 Oct 2014. http://www.abs.gov.au/ausstats/[email protected]/Lookup/by%20Subject/4338.0-2011-13-Main%20Features-Overweight%20and%20obesity-10007 Tao, 2013, Association between γ-glutamyl transferase and metabolic syndrome: a cross-sectional study of an adult population in Beijing, Int J Environ Res Public Health, 10, 5523, 10.3390/ijerph10115523 Sakamoto, 2013, Comparison of the impact of changes in waist circumference and body mass index in relation to changes in serum gamma-glutamyltransferase levels, J Atheroscler Thromb, 20, 142, 10.5551/jat.14415 Koerbin, 2013, Effect of population selection on 99th percentile values for a high sensitivity cardiac troponin I and T assays, Clin Biochem, 46, 1636, 10.1016/j.clinbiochem.2013.08.004 Yang, 2004, Performance characteristics of eight Estradiol immunoassays, Am J Clin Pathol, 122, 332, 10.1309/5N2R4HT4GM0AGPBY Górriz Pintado, 2014, Influence of the immunoassay used in measurement of serum vitamin D levels, Endocrinol Nutr, 61, 123, 10.1016/j.endonu.2013.04.015 Bhattacharya, 1967, A simple method of resolution of a distribution into gaussian components, Biometrics, 23, 115, 10.2307/2528285 Hoffmann, 2012, Reference intervals of extended erythrocyte and reticulocyte parameters, Clin Chem Lab Med, 50, 941, 10.1515/cclm-2011-0796 Grossi Colombo, 2005, The REALAB Project: A New Method for the Formulation of Reference Intervals Based on Current Data, Clin Chem, 51, 1232, 10.1373/clinchem.2005.047787 Katayev, 2010, Establishing reference intervals for clinical laboratory test results is there a better way?, Am J Clin Pathol, 133, 180, 10.1309/AJCPN5BMTSF1CDYP Tate, 2012, The AACB workshop on harmonised reference limits—recommendations for adult reference intervals, Clin Biochem Rev, 33, S40