Quelle est la technique de référence pour la méthode fermée ? Valeur des tests de sécurité

Journal de Chirurgie Viscérale - Tập 149 - Trang 32-37 - 2012
M. Ouaïssi1,2, F. Pierre3, P. Collinet4, X. Deffieux5
1Faculté de médecine, université Aix-Marseille, 27, boulevard Jean-Moulin, 13385 Marseille cedex 05, France
2Pôle d’oncologie de spécialités médicales et chirurgicales, service de chirurgie digestive et viscérale, hôpital Timone, 264, rue Saint-Pierre, Bouche-du-Rhône, 13385 Marseille cedex 05, France
3Service de gynécologie obstétrique, CHU de Poitiers, 86000 Poitiers, France
4Service de gynécologie obstétrique, CHU Jeanne-de-Flandres, 59000 Lille, France
5Service de gynécologie obstétrique et médecine de la reproduction, hôpital Antoine-Béclère, 157, rue de la Porte-de-Trivaux, 92140 Clamart, France

Tài liệu tham khảo

Chapron, 1998, Surgical complications of diagnostic and operative gynaecological laparoscopy: a series of 29,966 cases, Hum Reprod, 13, 867, 10.1093/humrep/13.4.867 Chapron, 1997, Major vascular injuries during gynecologic laparoscopy, J Am Coll Surg, 185, 461, 10.1016/S1072-7515(01)00958-9 Ahmad, 2008, Laparoscopic entry techniques, Cochrane Database Syst Rev, 2, CD006583 El-Hakim, 2004, Peritoneal and systemic inflammatory mediators of laparoscopic bowel injury in a rabbit model, J Urol, 172, 1515, 10.1097/01.ju.0000131002.29322.7d Van Der Krabben, 2000, Morbidity and mortality of inadvertent enterotomy during adhesiotomy, Br J Surg, 87, 467, 10.1046/j.1365-2168.2000.01394.x Collinet P, Ballester M, Fauconnier A, et al. Risks associated with laparoscopic entry. J Gynecol Obstet Biol Reprod (Paris)2010;39:S123–35. Azevedo, 2009, Injuries caused by Veress needle insertion for creation of pneumoperitoneum: a systematic literature review, Surg Endosc, 23, 1428, 10.1007/s00464-009-0383-9 Rohatgi, 2004, Left subcostal closed (Veress needle) approach is a safe method for creating a pneumoperitoneum, J Laparoendosc Adv Surg Tech A, 14, 278, 10.1089/lap.2004.14.278 Tulikangas, 2003, Left upper quadrant cannula insertion, Fertil Steril, 79, 411, 10.1016/S0015-0282(02)04668-X Tufek, 2010, Primary left upper quadrant (Palmer's point) access for laparoscopic radical prostatectomy, Urol J, 7, 152 Kaloo, 2002, A survey of entry techniques and complications of members of the Australian gynaecological endoscopy society, Aust N Z J Obstet Gynaecol, 42, 264, 10.1111/j.0004-8666.2002.00264.x Chang, 1994, Use of Palmer's Point for insertion of the operative laparoscope in patients with severe pelvic adhesions: experience of 17 cases, J Am Assoc Gynecol Laparosc, 1, S7, 10.1016/S1074-3804(05)80888-6 Nezhat, 1998, Laparoscopic appraisal of the anatomic relationship of the umbilicus to the aortic bifurcation, J Am Assoc Gynecol Laparosc, 5, 135, 10.1016/S1074-3804(98)80079-0 Sriprasad, 2006, Positional anatomy of vessels that may be damaged at laparoscopy: new access criteria based on CT and ultrasonography to avoid vascular injury, J Endourol, 20, 498, 10.1089/end.2006.20.498 Hurd, 1992, The relationship of the umbilicus to the aortic bifurcation: implications for laparoscopic technique, Obstet Gynecol, 80, 48 Polyzos, 2007, Where is the aorta? Is it worth palpating the aorta prior to laparoscopy?, Acta Obstet Gynecol Scand, 86, 235, 10.1080/00016340601090147 Muzii, 2006, Mechanical bowel preparation before gynecologic laparoscopy: a randomized, single-blind, controlled trial, Fertil Steril, 85, 689, 10.1016/j.fertnstert.2005.08.049 Briel, 2000, Is it necessary to lift the abdominal wall when preparing a pneumoperitoneum? A randomized study, Surg Endosc, 14, 862, 10.1007/s004640000105 Shamiyeh, 2009, Lifting of the umbilicus for the installation of pneumoperitoneum with the Veress needle increases the distance to the retroperitoneal and intraperitoneal structures, Surg Endosc, 23, 313, 10.1007/s00464-008-9920-1 Teoh, 2005, An evaluation of four tests used to ascertain Veres needle placement at closed laparoscopy, J Minim Invasive Gynecol, 12, 153, 10.1016/j.jmig.2005.01.011 Vilos, 2009, Three simple steps during closed laparoscopic entry may minimize major injuries, Surg Endosc, 23, 758, 10.1007/s00464-008-0060-4 Yoong, 2010, The pressure profile test is more sensitive and specific than Palmer's test in predicting correct placement of the Veress needle, Eur J Obstet Gynecol Reprod Biol, 152, 210, 10.1016/j.ejogrb.2010.06.007 Garry, 2006, Laparoscopic surgery, Best Pract Res Clin Obstet Gynaecol, 20, 89, 10.1016/j.bpobgyn.2005.10.003 Abu-Rafea, 2005, High-pressure laparoscopic entry does not adversely affect cardiopulmonary function in healthy women, J Minim Invasive Gynecol, 12, 475, 10.1016/j.jmig.2005.07.393 Soderstrom, 1996, Injuries to major blood vessels during laparoscopy, J Am Assoc Gynecol Laparosc, 3, S47, 10.1016/S1074-3804(96)80295-7 Chapron, 2000, Major vascular complications from gynecologic laparoscopy, Gynecol Obstet Fertil, 28, 880, 10.1016/S1297-9589(00)00025-4 Bhoyrul, 2001, Trocar injuries in laparoscopic surgery, J Am Coll Surg, 192, 677, 10.1016/S1072-7515(01)00913-9 Tews, 1991, Significant reduction of operational risk in laparoscopy through the use of a new blunt trocar, Surg Gynecol Obstet, 173, 67 Tarnay, 1999, Entry force and intra-abdominal pressure associated with six laparoscopic trocar-cannula systems: a randomized comparison, Obstet Gynecol, 94, 83, 10.1016/S0029-7844(99)00288-4 Audebert, 2000, Role of microlaparoscopy in the diagnosis of peritoneal and visceral adhesions and in the prevention of bowel injury associated with blind trocar insertion, Fertil Steril, 73, 631, 10.1016/S0015-0282(99)00555-5 Childers, 1993, Laparoscopy using the left upper quadrant as the primary trocar site, Gynecol Oncol, 50, 221, 10.1006/gyno.1993.1196 Brill, 1995, The incidence of adhesions after prior laparotomy: a laparoscopic appraisal, Obstet Gynecol, 85, 269, 10.1016/0029-7844(94)00352-E Lecuru, 2001, Laparoscopy in patients with prior surgery: results of the blind approach, JSLS, 5, 13 Rafii, 2005, Previous abdominal surgery and closed entry for gynaecological laparoscopy: a prospective study, BJOG, 112, 100, 10.1111/j.1471-0528.2004.00298.x van der Voort, 2004, Bowel injury as a complication of laparoscopy, Br J Surg, 91, 1253, 10.1002/bjs.4716 Yim, 2001, Randomized double-masked comparison of radially expanding access device and conventional cutting tip trocar in laparoscopy, Obstet Gynecol, 97, 435, 10.1016/S0029-7844(00)01156-X Bisgaard, 2007, Randomized clinical trial comparing radially expanding trocars with conventional cutting trocars for the effects on pain after laparoscopic cholecystectomy, Surg Endosc, 21, 2012, 10.1007/s00464-007-9517-0 Turner, 1996, A new, radially expanding access system for laparoscopic procedures versus conventional cannulas, J Am Assoc Gynecol Laparosc, 3, 609, 10.1016/S1074-3804(05)80175-6 Venkatesh, 2007, Prospective randomized comparison of cutting and dilating disposable trocars for access during laparoscopic renal surgery, JSLS, 11, 198