Choosing the appropriate sensitivity analysis method for building energy model-based investigations
Tài liệu tham khảo
Borgonovo, 2016, Sensitivity analysis: a review of recent advances, Eur. J. Oper. Res., 248, 869, 10.1016/j.ejor.2015.06.032
Petersen, 2010, Method and simulation program informed decisions in the early stages of building design, Energy Build., 42, 1113, 10.1016/j.enbuild.2010.02.002
Sun, 2015, Sensitivity analysis of macro-parameters in the system design of net zero energy building, Energy Build., 86, 464, 10.1016/j.enbuild.2014.10.031
Heiselberg, 2009, Application of sensitivity analysis in design of sustainable buildings, Renew. Energy, 34, 2030, 10.1016/j.renene.2009.02.016
Spitz, 2012, Practical application of uncertainty analysis and sensitivity analysis on an experimental house, Energy Build., 55, 459, 10.1016/j.enbuild.2012.08.013
Mara, 2008, Application of global sensitivity analysis of model output to building thermal simulations, Build. Simul., 1, 290, 10.1007/s12273-008-8129-5
Saltelli, 2010, Variance based sensitivity analysis of model output design and estimator for the total sensitivity index, Comput. Phys. Commun., 181, 259, 10.1016/j.cpc.2009.09.018
Sobol’, 2005, On global sensitivity analysis of quasi-Monte Carlo algorithms, Monte Carlo Methods Appl., 11, 83, 10.1163/1569396054027274
Sallaberry, 2008, Extension of Latin hypercube samples with correlated variables, Reliab. Eng. Syst. Saf., 93, 1047, 10.1016/j.ress.2007.04.005
Helton, 2006, Survey of sampling-based methods for uncertainty and sensitivity analysis, Reliab. Eng. Syst. Saf., 91, 1075, 10.1016/j.ress.2005.11.017
Saltelli, 2004
Saltelli, 2000, Sensitivity analysis as an ingredient of modeling, Stat. Sci., 15, 377, 10.1214/ss/1009213004
Morris, 1991, Factorial sampling plans for preliminary computational experiments, Technometrics, 33, 161, 10.1080/00401706.1991.10484804
Booth, 2012, Handling uncertainty in housing stock models, Build. Environ., 48, 35, 10.1016/j.buildenv.2011.08.016
Le Dréau, 2014, Sensitivity analysis of the thermal performance of radiant and convective terminals for cooling buildings, Energy Build., 82, 482, 10.1016/j.enbuild.2014.07.002
Hemsath, 2015, Sensitivity analysis evaluating basic building geometry's effect on energy use, Renew. Energy, 76, 526, 10.1016/j.renene.2014.11.044
Østergård, 2015, A stochastic and holistic method to support decision-making in early building design
Østergård, 2016, Thermal comfort in residential buildings by the millions – early design support from stochastic simulations
Sobol’, 1993, Sensitivity estimates for nonlinear mathematical models, Math. Model. Comput. Exp., 1, 407
Cukier, 1973, Study of the sensitivity of coupled reaction systems to uncertainties in rate coefficients. I theory, J. Chem. Phys., 59, 38, 10.1063/1.1680571
Saltelli, 1999, A quantitative model-independent method for global sensitivity analysis of model output, Technometrics, 41, 39, 10.1080/00401706.1999.10485594
Mechri, 2010, Use of the ANOVA approach for sensitive building energy design, Appl. Energy, 87, 3073, 10.1016/j.apenergy.2010.04.001
Shen, 2013, Sensitivity analysis on daylighting and energy performance of perimeter offices with automated shading, Build. Environ., 59, 303, 10.1016/j.buildenv.2012.08.028
ISO 13790:2008, 2008
Jensen, 1995
Bourges, 1992
Campolongo, 1996, The use of graph theory in the sensitivity analysis of the model output: a second order screening method, Reliab. Eng. Syst. Saf., 64, 1, 10.1016/S0951-8320(98)00008-8
Sanchez, 2014, Application of sensitivity analysis in building energy simulations: combining first- and second-order elementary effects methods, Energy Build., 68, 741, 10.1016/j.enbuild.2012.08.048
Lam, 1996, Sensitivity analysis of energy performance of office buildings, Build. Environ., 31, 27, 10.1016/0360-1323(95)00031-3
Kim, 2013, Stochastic comparison between simplified energy calculation and dynamic simulation, Energy Build., 64, 332, 10.1016/j.enbuild.2013.05.026
Liu, 2014, Development and sensitivity study of a simplified and dynamic method for double glazing facade and verified by a full-scale facade element, Energy Build., 68, 432, 10.1016/j.enbuild.2013.03.056
Homma, 1996, Importance measures in global sensitivity analysis of nonlinear models, Reliab. Eng. Syst. Saf., 52, 1, 10.1016/0951-8320(96)00002-6