The Mechanical Behavior of Locking Compression Plates Compared With Dynamic Compression Plates in a Cadaver Radius Model

Journal of Orthopaedic Trauma - Tập 19 Số 9 - Trang 597-603 - 2005
Michael J. Gardner1, Robert H. Brophy, Deirdre Campbell, Amit Mahajan, Timothy M. Wright, David L. Helfet, Dean G. Lorich
1Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA. [email protected]

Tóm tắt

Từ khóa


Tài liệu tham khảo

Turner, 1992, Comparison of bone screw holding strength in healthy bovine and osteoporotic human cancellous bone., Clin Mater, 9, 105, 10.1016/0267-6605(92)90054-W

Mainil-Varlet, 1997, The use of a resorbable augmentation device to secure plating of osteoporotic bones. An in vitro study., Int Orthop, 21, 217, 10.1007/s002640050154

Hertel, 1990, [Osteosynthesis in high-grade osteoporosis.] Unfallchirurg., [in German], 93, 479

Beaupre, 1988, Stresses in plated long-bones: the role of screw tightness and interface slipping., J Orthop Res, 6, 39, 10.1002/jor.1100060106

Beaupre, 1988, A biomechanical assessment of plate fixation, with insufficient bony support., J Orthop Res, 6, 721, 10.1002/jor.1100060515

Stern, 1983, Complications of plate fixation of forearm fractures., Clin Orthop Relat Res, 25-, 29

Klaue, 1991, Internal fixation with a self-compressing plate and lag screw: improvements of the plate hole and screw design. 2. In vivo investigations., J Orthop Trauma, 5, 289, 10.1097/00005131-199109000-00006

Klaue, 2000, Long-term effects of plate osteosynthesis: comparison of four different plates., Injury, 31, S

Perren, 1988, Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection?, Clin Orthop Relat Res, 139-, 151

Claes, 1989, The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity., J Orthop Res, 7, 170, 10.1002/jor.1100070203

Eijer, 2001, PC-Fix and local infection resistance-influence of implant design on postoperative infection development, clinical and experimental results., Injury, 32, S

Arens, 1996, Infection after open reduction and internal fixation with dynamic compression plates-clinical and experimental data., Injury, 27, SC27

Perren, 2002, Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology., J Bone Joint Surg Br, 84, 1093, 10.1302/0301-620X.84B8.0841093

Gardner, 2004, Has locked plating completely replaced conventional plating?, Am J Orthop, 33, 439

Oxland, 1996, The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance. An in vitro study., Spine, 21, 2558, 10.1097/00007632-199611150-00005

Heini, 2001, Augmentation of mechanical properties in osteoporotic vertebral bones-a biomechanical investigation of vertebroplasty efficacy with different bone cements., Eur Spine J, 10, 164, 10.1007/s005860000204

Trivitayaratana, 2001, Evaluation of forearm bone mineral density: comparison of dominant and non-dominant forearms., J Med Assoc Thai, 84, 223

Landis, 1977, The measurement of observer agreement for categorical data., Biometrics, 33, 159, 10.2307/2529310

Borgeaud, 2000, Mechanical analysis of the bone to plate interface of the LC-DCP and of the PC-FIX on human femora., Injury, 31, C29, 10.1016/S0020-1383(00)80029-7

Cordey, 2000, Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone., Injury, 31, C21, 10.1016/S0020-1383(00)80028-5

Goesling, 2003, LISS PLT: design, mechanical and biomechanical characteristics., Injury, 34, A11, 10.1016/S0020-1383(03)00253-5

Bong, 2002, Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty., J Arthroplasty, 17, 876, 10.1054/arth.2002.34817

Jazrawi, 2000, New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation., J Trauma, 48, 87, 10.1097/00005373-200001000-00015

Simon, 1999, Schuhli augmentation of plate and screw fixation for humeral shaft fractures: a laboratory study., J Orthop Trauma, 13, 196, 10.1097/00005131-199903000-00007

Jazrawi, 2000, A biomechanical comparison of Schuhli nuts or cement augmented screws for plating of humeral fractures., Clin Orthop Relat Res, 235-, 240

Miclau, 1995, A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator., J Orthop Trauma, 9, 17, 10.1097/00005131-199502000-00003

Fleck, 2003, Deformation behaviour and damage accumulation of cortical bone specimens from the equine tibia under cyclic loading., J Biomech, 36, 179, 10.1016/S0021-9290(02)00364-0

Pattin, 1996, Cyclic mechanical property degradation during fatigue loading of cortical bone., J Biomech, 29, 69, 10.1016/0021-9290(94)00156-1

Stoffel, 2003, Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?, Injury, 34, B11, 10.1016/j.injury.2003.09.021

Schatzker, 1975, The holding power of orthopedic screws in vivo., Clin Orthop Relat Res, 115-, 126

Burstein, 1972, Bone strength. The effect of screw holes., J Bone Joint Surg Am, 54, 1143, 10.2106/00004623-197254060-00001

Schatzker, 1975, The effect of movement on the holding power of screws in bone., Clin Orthop Relat Res, 257-, 262

Uhthoff, 1973, Mechanical factors influencing the holding power of screws in compact bone., J Bone Joint Surg Br, 55, 633, 10.1302/0301-620X.55B3.633