Assessment of Intermediate Severity Coronary Lesions in the Catheterization Laboratory

Journal of the American College of Cardiology - Tập 49 - Trang 839-848 - 2007
Jonathan Tobis1, Babak Azarbal1, Leo Slavin1
1David Geffen School of Medicine at UCLA, Department of Medicine (Division of Cardiology), Los Angeles, California.

Tài liệu tham khảo

Stone, 2004, One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial, Circulation, 109, 1942, 10.1161/01.CIR.0000127110.49192.72 Moses, 2003, Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery, N Engl J Med, 349, 1315, 10.1056/NEJMoa035071 Gould, 1974, Physiologic basis for assessing critical coronary stenosis, Am J Cardiol, 33, 87, 10.1016/0002-9149(74)90743-7 DeRouen, 1977, Variability in the analysis of coronary arteriograms, Circulation, 55, 324, 10.1161/01.CIR.55.2.324 Goldberg, 1990, Comparison of quantitative coronary angiography to visual estimates of lesion severity pre and post PTCA, Am Heart J, 119, 178, 10.1016/S0002-8703(05)80098-5 Zir, 1983, Observer variability in coronary angiography, Int J Cardiol, 3, 171, 10.1016/0167-5273(83)90033-5 Vlodaver, 1973, Correlation of the antemortem coronary arteriogram and the postmortem specimen, Circulation, 47, 162, 10.1161/01.CIR.47.1.162 Grondin, 1974, Discrepancies between cineangiographic and postmortem findings in patients with coronary artery disease and recent myocardial revascularization, Circulation, 49, 703, 10.1161/01.CIR.49.4.703 Hutchins, 1977, Correlation of coronary arteriograms and left ventriculograms with postmortem studies, Circulation, 56, 32, 10.1161/01.CIR.56.1.32 Arnett, 1979, Coronary artery narrowing in coronary heart disease: comparison of cineangiographic and necropsy findings, Ann Intern Med, 91, 350, 10.7326/0003-4819-91-3-350 Blankenhorn, 1982, The accuracy of arteriography and ultrasound imaging for atherosclerosis measurement, Arch Pathol Lab Med, 106, 483 Nissen, 1990, Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions, Circulation, 81, 660, 10.1161/01.CIR.81.2.660 Tobis, 1991, Intravascular ultrasound, Circulation, 84, 2190, 10.1161/01.CIR.84.5.2190 Nissen, 1991, Application of intravascular ultrasound for detection and quantitation of coronary atherosclerosis, Int J Card Imaging, 6, 165, 10.1007/BF01797849 Tobis, 1993, Lessons from intravascular ultrasonography: observations during interventional angioplasty procedures, J Clin Ultrasound, 21, 589, 10.1002/jcu.1870210906 Glagov, 1987, Compensatory enlargement of human atherosclerotic coronary arteries, N Engl J Med, 316, 1371, 10.1056/NEJM198705283162204 Tobis, 1991, Intravascular ultrasound imaging of human coronary arteries in vivo, Circulation, 83, 913, 10.1161/01.CIR.83.3.913 Hodgson, 1993, Intracoronary ultrasound imaging: correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty, J Am Coll Cardiol, 21, 35, 10.1016/0735-1097(93)90714-C Hausmann, 1994, Lumen and plaque shape in atherosclerotic coronary arteries assessed by in vivo intracoronary ultrasound, Am J Cardiol, 74, 857, 10.1016/0002-9149(94)90576-2 Mintz, 1996, Limitations of angiography in the assessment of plaque distribution in coronary artery disease: a systematic study of target lesion eccentricity in 1446 lesions, Circulation, 93, 924, 10.1161/01.CIR.93.5.924 Nishioka, 1996, Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis: an in vivo intravascular ultrasound study, J Am Coll Cardiol, 27, 1571, 10.1016/0735-1097(96)00071-X Mintz, 1997, Contribution of inadequate arterial remodeling to the development of focal coronary artery stenoses, Circulation, 95, 1791, 10.1161/01.CIR.95.7.1791 Waller, 1980, Amount of narrowing by atherosclerotic plaque in 44 nonbypassed and 52 bypassed major epicardial coronary arteries in 32 necropsy patients who died within 1 month of aortocoronary bypass grafting, Am J Cardiol, 46, 956, 10.1016/0002-9149(80)90351-3 Keren, 1991, Characterization of atherosclerotic lesions by intravascular ultrasound: possible role in unstable coronary syndromes and in interventional therapeutic procedures, Am J Cardiol, 68, 85B, 10.1016/0002-9149(91)90389-3 Mintz, 1992, Target lesion calcification in coronary artery disease: an intravascular ultrasound study, J Am Coll Cardiol, 20, 1149, 10.1016/0735-1097(92)90371-S Mintz, 1995, Atherosclerosis in angiographically “normal” coronary artery reference segments: an intravascular ultrasound study with clinical correlations, J Am Coll Cardiol, 25, 1479, 10.1016/0735-1097(95)00088-L Fisher, 1982, Reproducibility of coronary arteriographic reading in the Coronary Artery Surgery Study (CASS), Cathet Cardiovasc Diagn, 8, 565, 10.1002/ccd.1810080605 Hausmann, 1995, The safety of intracoronary ultrasound, Circulation, 91, 623, 10.1161/01.CIR.91.3.623 Bocksch, 1998, Safety of intracoronary ultrasound imaging in patients with acute myocardial infarction, Am J Cardiol, 81, 641, 10.1016/S0002-9149(97)00989-2 Schaar, 2006, Intravascular palpography for vulnerable plaque assessment, J Am Coll Cardiol, 47, C86, 10.1016/j.jacc.2006.01.035 Sipahi, 2006, Recent trends in coronary intravascular ultrasound: tracking atherosclerosis, pursuit of vulnerable plaques, and beyond, J Nucl Cardiol, 13, 91, 10.1016/j.nuclcard.2005.11.001 Nissen, 2001, Intravascular ultrasound: novel pathophysiological insights and current clinical applications, Circulation, 103, 602, 10.1161/01.CIR.103.4.604 Dimitrow, 2005, The non-invasive documentation of coronary microcirculation impairment: role of transthoracic echocardiography, Cardiovasc Ultrasound, 3, 18, 10.1186/1476-7120-3-18 Gould, 1990, Coronary flow reserve as a physiologic measure of stenosis severity, J Am Coll Cardiol, 15, 459, 10.1016/S0735-1097(10)80078-6 Doucette, 1992, Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity, Circulation, 85, 1899, 10.1161/01.CIR.85.5.1899 Labovitz, 1993, Validation of volumetric flow measurements by means of a Doppler-tipped coronary angioplasty guide wire, Am Heart J, 126, 1456, 10.1016/0002-8703(93)90545-K Miller, 1994, Correlation of pharmacological 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses, Circulation, 89, 2150, 10.1161/01.CIR.89.5.2150 McGinn, 1990, Interstudy variability of coronary flow reserve, Circulation, 81, 1319, 10.1161/01.CIR.81.4.1319 Heller, 1997, Intracoronary Doppler assessment of moderate coronary artery disease: comparison with 201Tl imaging and coronary angiography, Circulation, 96, 484, 10.1161/01.CIR.96.2.484 Lorenzoni, 1998, Coronary vasodilator reserve is impaired in patients with hypertrophic cardiomyopathy and left ventricular dysfunction, Am Heart J, 136, 972, 10.1016/S0002-8703(98)70152-8 Czernin, 1993, Influence of age and hemodynamics on myocardial blood flow and flow reserve, Circulation, 88, 62, 10.1161/01.CIR.88.1.62 Akasaka, 1997, Retinopathy identifies marked restriction of coronary flow reserve in patients with diabetes mellitus, J Am Coll Cardiol, 30, 935, 10.1016/S0735-1097(97)00242-8 Schafer, 2002, Left ventricular remodeling impairs coronary flow reserve in hypertensive patients, J Hypertens, 30, 31 Voudris, 2003, Relative coronary flow velocity reserve improves correlation with stress myocardial perfusion imaging in assessment of coronary artery stenoses, Chest, 124, 1266, 10.1378/chest.124.4.1266 Pijls, 1993, Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty, Circulation, 87, 1354, 10.1161/01.CIR.87.4.1354 Kern, 1997, From research to clinical practice: current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory, J Am Coll Cardiol, 30, 613, 10.1016/S0735-1097(97)00224-6 Pijls, 1996, Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses, N Engl J Med, 334, 1703, 10.1056/NEJM199606273342604 De Bruyne, 1996, Simultaneous coronary pressure and flow velocity measurements in humans, Circulation, 94, 1842, 10.1161/01.CIR.94.8.1842 Caymaz, 2000, Correlation of myocardial fractional flow reserve with thallium-201 SPECT imaging in intermediate-severity coronary artery lesions, J Invasive Cardiol, 12, 345 Leesar, 2003, Use of fractional flow reserve versus stress perfusion scintigraphy after unstable angina, J Am Coll Cardiol, 41, 1115, 10.1016/S0735-1097(03)00057-3 Kern, 1995, Clinical outcome of deferring angioplasty in patients with normal translesional pressure-flow velocity measurements, J Am Coll Cardiol, 25, 178, 10.1016/0735-1097(94)00328-N Bech, 1998, Long-term follow-up after deferral of percutaneous transluminal coronary angioplasty of intermediate stenosis on the basis of coronary pressure measurement, J Am Coll Cardiol, 31, 841, 10.1016/S0735-1097(98)00050-3 Bech, 2001, Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial, Circulation, 103, 2928, 10.1161/01.CIR.103.24.2928 Chamuleau, 2002, Usefulness of fractional flow reserve for risk stratification of patients with multivessel coronary artery disease and an intermediate stenosis, Am J Cardiol, 89, 377, 10.1016/S0002-9149(01)02255-X Hanekamp, 1999, Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment, Circulation, 99, 1015, 10.1161/01.CIR.99.8.1015 Pijls, 2002, Coronary pressure measurement after stenting predicts adverse events at follow-up: a multicenter registry, Circulation, 105, 2950, 10.1161/01.CIR.0000020547.92091.76 Rieber, 2002, Fractional flow reserve predicts major adverse cardiac events after coronary stent implantation, Z Kardiol, 91, 132, 10.1007/s00392-002-1324-y Hau, 2004, Fractional flow reserve and complex coronary pathologic conditions, Eur Heart J, 25, 723, 10.1016/j.ehj.2004.02.019 Di Segni, 2001, Incremental doses of intracoronary adenosine for the assessment of coronary velocity reserve for clinical decision making, Cathet Cardiovasc Intervent, 54, 34, 10.1002/ccd.1234 Yamada, 1994, Intracoronary adenosine 5’-triphosphate as an alternative to papaverine for measuring coronary flow reserve, Am J Cardiol, 74, 940, 10.1016/0002-9149(94)90591-6 Sonoda, 1998, Safety and optimal dose of intracoronary adenosine 5’-triphosphate for the measurement of coronary flow reserve, Am Heart J, 135, 621, 10.1016/S0002-8703(98)70277-7 Jeremias, 2000, Effects of intravenous and intracoronary 5’-triphosphate as compared with adenosine on coronary flow and pressure dynamics, Circulation, 101, 318, 10.1161/01.CIR.101.3.318 Wilson, 1986, Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans, Circulation, 73, 444, 10.1161/01.CIR.73.3.444 Bartunek, 1999, Effects of dobutamine on coronary stenosis physiology and morphology: comparison with intracoronary adenosine, Circulation, 100, 243, 10.1161/01.CIR.100.3.243 Engler, 1983, Leukocyte capillary plugging in myocardial ischemia and reperfusion in the dog, Am J Pathol, 111, 98 Lenzen, 2005, Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization, Eur Heart J, 26, 1169, 10.1093/eurheartj/ehi238 Bech, 2001, Value of fractional flow reserve in making decisions about bypass surgery for equivocal left main coronary artery disease, Heart, 86, 547, 10.1136/heart.86.5.547 Abizaid, 1999, One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms, J Am Coll Cardiol, 34, 707, 10.1016/S0735-1097(99)00261-2 Leesar, 2004, Physiological and intravascular ultrasound assessment of an ambiguous left main coronary artery stenosis, Catheter Cardiovasc Interv, 62, 349, 10.1002/ccd.20038 Jasti, 2004, Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis, Circulation, 110, 2831, 10.1161/01.CIR.0000146338.62813.E7 Pijls, 2000, Coronary pressure measurement to assess the hemodynamic significance of serial stenoses within one coronary artery: validation in humans, Circulation, 102, 2371, 10.1161/01.CIR.102.19.2371 Fitzgibbon, 1996, Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years, J Am Coll Cardiol, 28, 616, 10.1016/0735-1097(96)00206-9 Reeves, 1991, Long-term angiographic follow-up after angioplasty of venous coronary bypass grafts, Am Heart J, 122, 620, 10.1016/0002-8703(91)90503-A Murphy, 2004, Insights into the pathogenesis of vein graft disease: lessons from intravascular ultrasound, Cardiovasc Ultrasound, 2, 8, 10.1186/1476-7120-2-8 Wong, 1995, Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: the multicenter U.S. Palmaz-Schatz stent experience, J Am Coll Cardiol, 26, 704, 10.1016/0735-1097(95)00217-R Choussat, 2000, Long-term clinical outcome after endoluminal reconstruction of diffusely degenerated saphenous vein grafts with less-shortening wallstents, J Am Coll Cardiol, 36, 387, 10.1016/S0735-1097(00)00724-5 Mendelsohn, 1995, In vivo assessment by intravascular ultrasound of enlargement in saphenous vein bypass graft, Am J Cardiol, 76, 1066, 10.1016/S0002-9149(99)80299-9 Murphy, 2004, Insights into the pathogenesis of vein graft disease: lessons from intravascular ultrasound, Cardiovasc Ultrasound, 2, 8, 10.1186/1476-7120-2-8 Hong, 1999, Intravascular ultrasound assessment of the presence of vascular remodeling in diseased human saphenous bypass grafts, Am J Cardiol, 84, 992, 10.1016/S0002-9149(99)00486-5 Salm, 2005, Hemodynamic evaluation of saphenous vein coronary artery bypass grafts: relative merits of Doppler flow velocity and SPECT perfusion imaging, J Nucl Cardiol, 12, 545, 10.1016/j.nuclcard.2005.04.015 George, 1986, Balloon angioplasty of coronary bifurcation lesions: the kissing balloon technique, Cathet Cardiovasc Diagn, 12, 124, 10.1002/ccd.1810120212 Yamashita, 2000, Bifurcation lesions: two stents versus one stent—immediate and follow-up results, J Am Coll Cardiol, 35, 1145, 10.1016/S0735-1097(00)00534-9 Al Suwaidi, 2000, Immediate and long-term outcome of intracoronary stent implantation for true bifurcation lesions, J Am Coll Cardiol, 35, 929, 10.1016/S0735-1097(99)00648-8 Costa, 2005, Bifurcation coronary lesions treated with the “crush” technique: an intravascular ultrasound analysis, J Am Coll Cardiol, 46, 599, 10.1016/j.jacc.2005.05.034 Colombo, 2004, Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions, Circulation, 109, 1244, 10.1161/01.CIR.0000118474.71662.E3 Ziaee, 2004, Lack of relation between imaging and physiology in ostial coronary artery narrowings, Am J Cardiol, 93, 1404, 10.1016/j.amjcard.2004.02.041 Brueck, 2004, Comparison of interventional versus conservative treatment of isolated ostial lesions of coronary diagonal branch arteries, Am J Cardiol, 93, 1162, 10.1016/j.amjcard.2004.01.048 Koo, 2005, Physiologic assessment of jailed side branch lesions using fractional flow reserve, J Am Coll Cardiol, 46, 633, 10.1016/j.jacc.2005.04.054 Tamita, 2002, Effects of microvascular dysfunction on myocardial fractional flow reserve after percutaneous coronary intervention in patients with acute myocardial infarction, Catheter Cardiovasc Interv, 57, 452, 10.1002/ccd.10350 Muramatsu, 2002, Usefulness of fractional flow reserve guidance for PCI in acute myocardial infarction, J Invasive Cardiol, 14, 657 Claeys, 2001, Reliability of fractional flow reserve measurements in patients with associated microvascular dysfunction: importance of flow on translesional pressure gradient, Catheter Cardiovasc Interv, 54, 427, 10.1002/ccd.2005 De Bruyne, 2001, Fractional flow reserve in patients with prior myocardial infarction, Circulation, 104, 157, 10.1161/01.CIR.104.2.157 Usui, 2003, Reliability of pressure-derived myocardial fractional flow reserve in assessing coronary artery stenosis in patients with previous myocardial infarction, Am J Cardiol, 92, 699, 10.1016/S0002-9149(03)00829-4 Potvin, 2006, Usefulness of fractional flow reserve measurements to defer revascularization in patients with stable or unstable angina pectoris, non–ST-elevation and ST-elevation acute myocardial infarction, or atypical chest pain, Am J Cardiol, 98, 289, 10.1016/j.amjcard.2006.02.032 Legalery, 2005, One-year outcome of patients submitted to routine fractional flow reserve assessment to determine the need for angioplasty, Eur Heart J, 26, 2623, 10.1093/eurheartj/ehi484 Hernandez-Garcia, 2001, Clinical management of patients with coronary syndromes and negative fractional flow reserve findings, J Interv Cardiol, 14, 505, 10.1111/j.1540-8183.2001.tb00366.x Lopez-Palop, 2004, Utility of the fractional flow reserve in the evaluation of angiographically moderate in-stent restenosis, Eur Heart J, 25, 2040, 10.1016/j.ehj.2004.07.016 Hasegawa, 2006, Acute myocardial infarction: clinical characteristics and plaque morphology between expansive remodeling and constrictive remodeling by intravascular ultrasound, Am Heart J, 151, 332, 10.1016/j.ahj.2005.03.041 von Birgelen, 2001, Plaque distribution and vascular remodeling of ruptured and nonruptured coronary plaques in the same vessel: an intravascular ultrasound study in vivo, J Am Coll Cardiol, 37, 1864, 10.1016/S0735-1097(01)01234-7 Ohlmann, 2005, Cardiovascular events in patients with coronary plaque rupture and nonsignificant stenosis, Am J Cardiol, 96, 1631, 10.1016/j.amjcard.2005.07.087 Rioufol, 2004, Evolution of spontaneous atherosclerotic plaque rupture with medical therapy: long-term follow-up with intravascular ultrasound, Circulation, 110, 2875, 10.1161/01.CIR.0000146337.05073.22 Fujii, 2005, Creatine kinase-MB enzyme elevation and long-term clinical events after successful coronary stenting in lesions with ruptured plaque, Am J Cardiol, 95, 355, 10.1016/j.amjcard.2004.09.033 Klein, 2003, Society of Cardiac Angiography and Interventions: suggested management of the no-reflow phenomenon in the cardiac catheterization laboratory, Catheter Cardiovasc Interv, 60, 194, 10.1002/ccd.10620 Ito, 1996, Myocardial perfusion patterns related to thrombolysis in myocardial infarction perfusion grades after coronary angioplasty in patients with acute anterior wall myocardial infarction, Circulation, 93, 1993, 10.1161/01.CIR.93.11.1993 Tanaka, 2002, No-reflow phenomenon and lesion morphology in patients with acute myocardial infarction, Circulation, 105, 2148, 10.1161/01.CIR.0000015697.59592.07 Iijima, 2006, Comparison of coronary arterial finding by intravascular ultrasound in patients with “transient no-reflow” versus “reflow” during percutaneous coronary intervention in acute coronary syndrome, Am J Cardiol, 97, 29, 10.1016/j.amjcard.2005.07.104 Lim, 2005, Utility of coronary physiologic hemodynamics for bifurcation, aorto-ostial, and ostial branch stenoses to guide treatment decisions, Catheter Cardiovasc Interv, 65, 461, 10.1002/ccd.20435 Nishioka, 1999, Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity: comparison with stress myocardial perfusion imaging, J Am Coll Cardiol, 33, 1870, 10.1016/S0735-1097(99)00100-X Abizaid, 1998, Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty, Am J Cardiol, 82, 423, 10.1016/S0002-9149(98)00355-5 Takagi, 1999, Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis: relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve, Circulation, 100, 250, 10.1161/01.CIR.100.3.250 Briguori, 2001, Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve, Am J Cardiol, 87, 136, 10.1016/S0002-9149(00)01304-7 Orford, 2004, Routine intravascular ultrasound guidance of percutaneous coronary intervention, J Am Coll Cardiol, 43, 1335, 10.1016/j.jacc.2003.12.035 Fearon, 2001, Fractional flow reserve compared with intravascular ultrasound guidance for optimizing stent deployment, Circulation, 104, 1917, 10.1161/hc4101.097539 Bech, 1999, Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty, Circulation, 99, 883, 10.1161/01.CIR.99.7.883