Complications of laser in situ keratomileusis for the correction of myopia

Ophthalmology - Tập 106 - Trang 13-20 - 1999
R.Doyle Stulting1, Jonathan D Carr1, Keith P Thompson1, George O Waring1, Wendy M Wiley1, Judy G Walker1
1Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia USA

Tài liệu tham khảo

Pallikaris, 1990, Laser in situ keratomileusis, Lasers Surg Med, 10, 463, 10.1002/lsm.1900100511 Pallikaris, 1991, A corneal flap technique for laser in situ keratomileusis. Human studies, Arch Ophthalmol, 109, 1699, 10.1001/archopht.1991.01080120083031 Pallikaris, 1994, Excimer laser in situ keratomileusis and photorefractive keratectomy for correction of high myopia, J Refract Corneal Surg, 10, 498, 10.3928/1081-597X-19940901-07 Brint, 1994, Six-month results of the multicenter phase I study of excimer laser myopic keratomileusis, J Cataract Refract Surg, 20, 610, 10.1016/S0886-3350(13)80648-7 Kremer, 1995, Excimer laser in situ keratomileusis, J Refract Surg, 11, S244 Fiander, 1995, Excimer laser in situ keratomileusis in 124 myopic eyes, J Refract Surg, 11, S234 Salah, 1995, Excimer laser in-situ keratomileusis (LASIK) under a corneal flap for myopia of 2 to 20 D, Trans Am Ophthalmol Soc, 93, 163 Salah, 1996, Excimer laser in situ keratomileusis under a corneal flap for myopia of 2 to 20 diopters, Am J Ophthalmol, 121, 143, 10.1016/S0002-9394(14)70578-1 Kohlhaas, 1995, Keratomileusis mit einem lamellären Mikrokeratom und einem Excimer-Laser, Ophthalmologe, 92, 499 Bas, 1995, Excimer laser in situ keratomileusis for myopia, J Refract Surg, 11, S229 Guell, 1996, Laser in situ keratomileusis (LASIK) for myopia from −7 to −18 diopters, J Refract Surg, 12, 222, 10.3928/1081-597X-19960201-03 Marinho, 1996, LASIK for high myopia, Ophthalmic Surg Lasers, 27, S517 Helmy, 1996, Photorefractive keratectomy and laser in situ keratomileusis for myopia between 6.00 and 10.00 diopters, J Refract Surg, 12, 417, 10.3928/1081-597X-19960301-17 Gimbel, 1996, Experience during the learning curve of laser in situ keratomileusis, J. Cataract Refract Surg, 22, 542, 10.1016/S0886-3350(96)80006-X Knorz, 1996, Laser in situ keratomileusis to correct myopia of −6.00 to −29.00 diopters, J Refract Surg, 12, 575, 10.3928/1081-597X-19960701-09 Kim, 1996, Laser assisted in situ keratomileusis for high myopia, Ophthalmic Surg Lasers, 27, S508 Condon, 1997, Laser intrastromal keratomileusis for high myopia and myopic astigmatism, Br J Ophthalmol, 81, 199, 10.1136/bjo.81.3.199 Pallikaris, 1997, Laser in situ keratomileusis to treat myopia, J Cataract Refract Surg, 23, 39, 10.1016/S0886-3350(97)80149-6 Michels, 1990, 83 Verity, 1995, The combined (Genesis) technique of radial keratotomy. A prospective, multicenter study. Refractive Keratoplasty Study Group, Ophthalmology, 102, 1908, 10.1016/S0161-6420(95)30776-2 Waring, 1994, Results of the prospective evaluation of radial keratotomy (PERK) study 10 years after surgery, Arch Ophthalmol, 112, 1298, 10.1001/archopht.1994.01090220048022 Chatterjee, 1997, Results of excimer laser retreatment of residual myopia after previous photorefractive keratectomy, Ophthalmology, 104, 1321, 10.1016/S0161-6420(97)30140-7 Hefetz, 1997, Results of a repeated excimer laser photorefractive keratectomy for myopia, Ophthalmic Surg Lasers, 28, 8, 10.3928/1542-8877-19970101-04 Matta, 1996, Excimer retreatment for myopic photorefractive keratectomy failures. Six- to 18-month follow-up, Ophthalmology, 103, 444, 10.1016/S0161-6420(96)30673-8 Epstein, 1994, Excimer retreatment of regression after photorefractive keratectomy, Am J Ophthalmol, 117, 456, 10.1016/S0002-9394(14)70004-2 Krueger, 1995, Clinical analysis of excimer laser photorefractive keratectomy using a multiple zone technique for severe myopia, Am J Ophthalmol, 119, 263, 10.1016/S0002-9394(14)71166-3 Lawless, 1994, Retreatment of undercorrected photorefractive keratectomy for myopia, J Refract Corneal Surg, 10, S174 Seiler, 1992, Repeated excimer laser treatment after photorefractive keratectomy, Arch Ophthalmol, 110, 1230, 10.1001/archopht.1992.01080210048021 Applegate, 1993, Magnification and visual acuity in refractive surgery, Arch Ophthalmol, 111, 1335, 10.1001/archopht.1993.01090100043025 Applegate, 1995, Experimental verification of computational methods to calculate magnification in refractive surgery, Arch Ophthalmol, 113, 571, 10.1001/archopht.1995.01100050037026 McCarty, 1996, Comparison of results of excimer laser correction of all degrees of myopia at 12 months postoperatively. The Melbourne Excimer Laser Group, Am J Ophthalmol, 121, 372, 10.1016/S0002-9394(14)70433-7 Sher, 1994, 193-nm excimer photorefractive keratectomy in high myopia, Ophthalmology, 101, 1575, 10.1016/S0161-6420(94)31135-3 Carson, 1995, Excimer laser treatment for high and extreme myopia. The Melbourne Excimer Laser and Research Group, Arch Ophthalmol, 113, 431, 10.1001/archopht.1995.01100040045025 Castanera, 1996, Topographic comparison of monozone, multipass and multizone ablations for myopic photorefractive keratectomy, Ophthalmic Surg Lasers, 27, S471 Rajendran, 1995, Multizone photorefractive keratectomy for myopia of 8 to 23 diopters, J Refract Surg, 11, S298 Rogers, 1994, Photorefractive keratectomy for myopia of more than −10 diopters, J Refract Corneal Surg, 10, S171 Amano, 1995, Excimer laser photorefractive keratectomy for myopia, J Refract Surg, 11, S253 Kim, 1995, Double-pass excimer laser photorefractive keratectomy, Korean J Ophthalmol, 9, 101, 10.3341/kjo.1995.9.2.101 Pop, 1995, Multizone/multipass photorefractive keratectomy, J Cataract Refract Surg, 21, 633, 10.1016/S0886-3350(13)80559-7