Standardization of cytokine flow cytometry assays

BMC Immunology - Tập 6 - Trang 1-18 - 2005
Holden T Maecker1, Aline Rinfret2, Patricia D'Souza3, Janice Darden3, Eva Roig2, Claire Landry2, Peter Hayes4, Josephine Birungi5, Omu Anzala6, Miguel Garcia7, Alexandre Harari7, Ian Frank8, Ruth Baydo8, Megan Baker9, Jennifer Holbrook9, Janet Ottinger9, Laurie Lamoreaux10, C Lorrie Epling11, Elizabeth Sinclair11, Maria A Suni1, Kara Punt12, Sandra Calarota13, Sophia El-Bahi14, Gailet Alter15, Hazel Maila16, Ellen Kuta17, Josephine Cox17, Clive Gray16, Marcus Altfeld15, Nolwenn Nougarede14, Jean Boyer13, Lynda Tussey12, Timothy Tobery12, Barry Bredt11, Mario Roederer10, Richard Koup10, Vernon C Maino1, Kent Weinhold9, Giuseppe Pantaleo7, Jill Gilmour4, Helen Horton8, Rafick P Sekaly2
1BD Biosciences, San Jose, USA
2Université de Montreal and CANVAC, the Canadian Network for Vaccines and Immunotherapeutics, Montreal, Canada
3National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, USA
4Chelsea and Westminster Hospital and IAVI, London
5Uganda Virus Research Institute and IAVI, Entebbe, Uganda
6Kenya AIDS Vaccine Initiative (KAVI), University of Nairobi, Kenya
7Centre Hospitalier Universitaire Vaudois and EUROVAC, Lausanne, Switzerland
8University of Washington and HVTN, Fred Hutchinson Cancer Research Center, Seattle, USA
9Duke University Medical Center and HVTN, Durham, USA
10Vaccine Research Center, National Institutes of Health, Bethesda, USA
11University of California, San Francisco, USA
12Merck and Co., West Point, USA
13University of Pennsylvania, Philadelphia, USA
14Sanofi Pasteur, Lyon, France
15Massachusetts General Hospital, Boston, USA
16National Institute for Communicable Diseases, Johannesburg, South Africa
17Henry Jackson Foundation, Rockville, USA

Tóm tắt

Cytokine flow cytometry (CFC) or intracellular cytokine staining (ICS) can quantitate antigen-specific T cell responses in settings such as experimental vaccination. Standardization of ICS among laboratories performing vaccine studies would provide a common platform by which to compare the immunogenicity of different vaccine candidates across multiple international organizations conducting clinical trials. As such, a study was carried out among several laboratories involved in HIV clinical trials, to define the inter-lab precision of ICS using various sample types, and using a common protocol for each experiment (see additional files online). Three sample types (activated, fixed, and frozen whole blood; fresh whole blood; and cryopreserved PBMC) were shipped to various sites, where ICS assays using cytomegalovirus (CMV) pp65 peptide mix or control antigens were performed in parallel in 96-well plates. For one experiment, antigens and antibody cocktails were lyophilised into 96-well plates to simplify and standardize the assay setup. Results (CD4+cytokine+ cells and CD8+cytokine+ cells) were determined by each site. Raw data were also sent to a central site for batch analysis with a dynamic gating template. Mean inter-laboratory coefficient of variation (C.V.) ranged from 17–44% depending upon the sample type and analysis method. Cryopreserved peripheral blood mononuclear cells (PBMC) yielded lower inter-lab C.V.'s than whole blood. Centralized analysis (using a dynamic gating template) reduced the inter-lab C.V. by 5–20%, depending upon the experiment. The inter-lab C.V. was lowest (18–24%) for samples with a mean of >0.5% IFNγ + T cells, and highest (57–82%) for samples with a mean of <0.1% IFNγ + cells. ICS assays can be performed by multiple laboratories using a common protocol with good inter-laboratory precision, which improves as the frequency of responding cells increases. Cryopreserved PBMC may yield slightly more consistent results than shipped whole blood. Analysis, particularly gating, is a significant source of variability, and can be reduced by centralized analysis and/or use of a standardized dynamic gating template. Use of pre-aliquoted lyophilized reagents for stimulation and staining can provide further standardization to these assays.

Tài liệu tham khảo

Suni MA, Dunn HS, Orr PL, deLaat R, Sinclair E, Ghanekar SA, Bredt BM, Dunne JF, Maino VC, Maecker HT: Performance of plate-based cytokine flow cytometry with automated data analysis. BMC Immunology. 2003, 4: 9- Maecker HT: Cytokine flow cytometry. In Flow Cytometry Protocols 2nd edition. Edited by: Hawley TS, Hawley RG. Totowa, NJ , Humana Press; 2004:95-107. Cox JH, Ferrari G, Kalams SA, Lopaczynski W, Oden N, Group ELISPOTS: Results of an ELISPOT proficiency panel conducted in 11 laboratories participating in international human immunodeficiency virus type 1 vaccine trials. AIDS Res Hum Retroviruses. 2005, McMichael AJ, Hanke T: HIV vaccines 1983-2003. Nat Med. 2003, 9 (7): 874-880. Pantaleo G, Koup RA: Correlates of immune protection in HIV-1 infection: what we know, what we don't know, what we should know. Nat Med. 2004, 10 (8): 806-810. Nomura LE, Walker JM, Maecker HT: Optimization of whole blood antigen-specific cytokine assays for CD4(+) T cells. Cytometry. 2000, 40 (1): 60-68. Landay A: Performance of single cell immune response assays. NCCLS Standards and Guidelines. 2004, Wayne, PA , NCCLS, I/LA26-A. Kern F, Faulhaber N, Frommel C, Khatamzas E, Prosch S, Schonemann C, Kretzschmar I, Volkmer-Engert R, Volk HD, Reinke P: Analysis of CD8 T cell reactivity to cytomegalovirus using protein- spanning pools of overlapping pentadecapeptides. Eur J Immunol. 2000, 30 (6): 1676-1682. Maecker HT, Dunn HS, Suni MA, Khatamzas E, Pitcher CJ, Bunde T, Persaud N, Trigona W, Fu TM, Sinclair E, Bredt BM, McCune JM, Maino VC, Kern F, Picker LJ: Use of overlapping peptide mixtures as antigens for cytokine flow cytometry. J Immunol Methods. 2001, 255 (1-2): 27-40. Kern F, Bunde T, Faulhaber N, Kiecker F, Khatamzas E, Rudawski IM, Pruss A, Gratama JW, Volkmer-Engert R, Ewert R, Reinke P, Volk HD, Picker LJ: Cytomegalovirus (CMV) phosphoprotein 65 makes a large contribution to shaping the T cell repertoire in CMV-exposed individuals. J Infect Dis. 2002, 185 (12): 1709-1716. Kleeberger CA, Lyles RH, Margolick JB, Rinaldo CR, Phair JP, Giorgi JV: Viability and recovery of peripheral blood mononuclear cells cryopreserved for up to 12 years in a multicenter study. Clin Diagn Lab Immunol. 1999, 6 (1): 14-19. Weinberg A, Zhang L, Brown D, Erice A, Polsky B, Hirsch MS, Owens S, Lamb K: Viability and functional activity of cryopreserved mononuclear cells. Clin Diagn Lab Immunol. 2000, 7 (4): 714-716. Currier JR, Kuta EG, Turk E, Earhart LB, Loomis-Price L, Janetzki S, Ferrari G, Birx DL, Cox JH: A panel of MHC class I restricted viral peptides for use as a quality control for vaccine trial ELISPOT assays. J Immunol Methods. 2002, 260 (1-2): 157-172. De Rosa SC, Lu FX, Yu J, Perfetto SP, Falloon J, Moser S, Evans TG, Koup R, Miller CJ, Roederer M: Vaccination in humans generates broad T cell cytokine responses. J Immunol. 2004, 173 (9): 5372-5380. Kuzushima K, Hoshino Y, Fujii K, Yokoyama N, Fujita M, Kiyono T, Kimura H, Morishima T, Morishima Y, Tsurumi T: Rapid determination of Epstein-Barr virus-specific CD8(+) T-cell frequencies by flow cytometry. Blood. 1999, 94 (9): 3094-3100. Moretto WJ, Drohan LA, Nixon DF: Rapid quantification of SIV-specific CD8 T cell responses with recombinant vaccinia virus ELISPOT or cytokine flow cytometry. Aids. 2000, 14 (16): 2625-2627. Asemissen AM, Nagorsen D, Keilholz U, Letsch A, Schmittel A, Thiel E, Scheibenbogen C: Flow cytometric determination of intracellular or secreted IFNgamma for the quantification of antigen reactive T cells. J Immunol Methods. 2001, 251 (1-2): 101-108. Pahar B, Li J, Rourke T, Miller CJ, McChesney MB: Detection of antigen-specific T cell interferon gamma expression by ELISPOT and cytokine flow cytometry assays in rhesus macaques. J Immunol Methods. 2003, 282 (1-2): 103-115. Sun Y, Iglesias E, Samri A, Kamkamidze G, Decoville T, Carcelain G, Autran B: A systematic comparison of methods to measure HIV-1 specific CD8 T cells. J Immunol Methods. 2003, 272 (1-2): 23-34. Whiteside TL, Zhao Y, Tsukishiro T, Elder EM, Gooding W, Baar J: Enzyme-linked immunospot, cytokine flow cytometry, and tetramers in the detection of T-cell responses to a dendritic cell-based multipeptide vaccine in patients with melanoma. Clin Cancer Res. 2003, 9 (2): 641-649. Karlsson AC, Martin JN, Younger SR, Bredt BM, Epling L, Ronquillo R, Varma A, Deeks SG, McCune JM, Nixon DF, Sinclair E: Comparison of the ELISPOT and cytokine flow cytometry assays for the enumeration of antigen-specific T cells. J Immunol Methods. 2003, 283 (1-2): 141-153. Dunne JF, Maecker HT: Automation of cytokine flow cytometry assays. J Assoc Lab Automation. 2004, 9: 5-9. Motulsky H: Intuitive Biostatistics. 1995, Oxford , Oxford Univ. Press, 199-200. Maecker HT: The role of immune monitoring in evaluatingcancer immunotherapy. In Immunotherapy of Cancer Edited by:Disis ML. Totowa, NJ , Humana Press; 2005. Trigona WL, Clair JH, Persaud N, Punt K, Bachinsky M, Sadasivan-Nair U, Dubey S, Tussey L, Fu TM, Shiver J: Intracellular staining for HIV-specific IFN-gamma production: statistical analyses establish reproducibility and criteria for distinguishing positive responses. J Interferon Cytokine Res. 2003, 23 (7): 369-377. Sinclair E, Black D, Epling CL, Carvidi A, Josefowicz SZ, Bredt BM, Jacobson MA: CMV antigen-specific CD4+ and CD8+ T cell IFNgamma expression and proliferation responses in healthy CMV-seropositive individuals. Viral Immunol. 2004, 17 (3): 445-454. Weinberg A, Wohl DA, Brown DG, Pott GB, Zhang L, Ray MG, van der Horst C: Effect of cryopreservation on measurement of cytomegalovirus-specific cellular immune responses in HIV-infected patients. J Acquir Immune Defic Syndr. 2000, 25 (2): 109-114. Costantini A, Mancini S, Giuliodoro S, Butini L, Regnery CM, Silvestri G, Montroni M: Effects of cryopreservation on lymphocyte immunophenotype and function. J Immunol Methods. 2003, 278 (1-2): 145-155. Lathey J: Preliminary steps toward validating a clinical bioassay: case study of the ELISpot assay. Biopharm Intl. 2003, March: 42-50. Lathey J, Sathiyaseelan J, Matijevic M, Hedley ML: Validation of pretrial ELISspot measurements. BioProcess Intl. 2003, Sept.: 34-41. Borg L, Kristiansen J, Christensen JM, Jepsen KF, Poulsen LK: Evaluation of accuracy and uncertainty of ELISA assays for the determination of interleukin-4, interleukin-5, interferon-gamma and tumor necrosis factor-alpha. Clin Chem Lab Med. 2002, 40 (5): 509-519. Findlay JW, Smith WC, Lee JW, Nordblom GD, Das I, DeSilva BS, Khan MN, Bowsher RR: Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective. J Pharm Biomed Anal. 2000, 21 (6): 1249-1273. Reimann KA, O'Gorman MR, Spritzler J, Wilkening CL, Sabath DE, Helm K, Campbell DE: Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system.The NIAID DAIDS New Technologies Evaluation Group. Clin Diagn Lab Immunol. 2000, 7 (3): 344-351. Koepke JA, Landay AL: Precision and accuracy of absolute lymphocyte counts. Clin Immunol Immunopathol. 1989, 52 (1): 19-27.