Reliability of the KT1000 arthrometer and the Lachman test in patients with an ACL rupture
Tài liệu tham khảo
Torg, 1976, Clinical diagnosis of anterior cruciate ligament instability in the athlete, Am J Sports Med, 4, 84, 10.1177/036354657600400206
Daniel, 1985, Instrumented measurement of anterior laxity of the knee, J Bone Joint Surg [Am]., 67, 720, 10.2106/00004623-198567050-00006
Anderson, 1992, Instrumented evaluation of knee laxity: a comparison of five arthrometers, Am J Sports Med, 20, 135, 10.1177/036354659202000207
Giannotti, 1996, The predictive value of intraoperative KT1000 arthrometer measurements in single incision anterior cruciate ligament reconstruction, Arthroscopy, 12, 660, 10.1016/S0749-8063(96)90167-X
Jonsson, 1993, Laxity after cruciate ligament injury in 94 knees. The KT-1000 arthrometer versus roentgen stereophotogrammetry, Acta Orthop Scand, 64, 567, 10.3109/17453679308993694
Malcom, 1985, The measurement of anterior knee laxity after ACL reconstructive surgery, Clin Orthop, 196, 35, 10.1097/00003086-198506000-00007
Bach, 1990, Arthrometric evaluation of knees that have a torn anterior cruciate ligament, J Bone Joint Surg [Am]., 72, 1299, 10.2106/00004623-199072090-00004
Liu, 1995, The diagnosis of acute complete tears of the anterior cruciate ligament. Comparison of MRI, arthrometry and clinical examination, J Bone Joint Surg [Br], 77, 586
Sherman, 1987, Measurements of anterior laxity in normal and anterior cruciate absent knees with two instrumented test devices, Clin Orthop, 215, 156, 10.1097/00003086-198702000-00023
Wroble, 1990, Repeatability of the KT-1000 arthrometer in a normal population, Am J Sports Med, 18, 396, 10.1177/036354659001800411
Forster, 1989, Is the KT1000 knee ligament arthrometer reliable?, J Bone Joint Surg [Br], 71, 843, 10.1302/0301-620X.71B5.2584257
Graham, 1991, Comparison of clinical tests and the KT1000 in the diagnosis of anterior cruciate ligament rupture, Br J Sports Med, 25, 96, 10.1136/bjsm.25.2.96
Jardin, 1999, Reliability of the KT-1000 arthrometer in measuring anterior laxity of the knee: comparative analysis with Telos of 48 reconstructions of the anterior cruciate ligament and intra- and interobserver reproducibility, Rev Chir Orthop Reparatrice Appar Mot, 85, 698
Hyder, 1997, Correlation between arthrometic evaluation of knees using KT1000 and Telos stress radiography and functional outcome following ACL reconstruction, The Knee, 4, 121, 10.1016/S0968-0160(97)00247-0
Holt, 1995, The KT-1000 arthrometer: is it accurate?, The Knee, 2, 59, 10.1016/0968-0160(95)93639-F
Laxdal, 2006, Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts: prospective randomized study of radiographic results and clinical outcome, Am J Sports Med, 34, 1574, 10.1177/0363546506288014
Liden, 2007, Patellar tendon or semitendinosus tendon autografts for anterior cruciate ligament reconstruction: a prospective, randomized study with a 7-Year follow-up, Am J Sports Med, 35, 740, 10.1177/0363546506298275
Muneta, 2007, A prospective randomized study of 4-strand semitendinosus tendon anterior cruciate ligament reconstruction comparing single-bundle and double-bundle techniques, Arthroscopy, 23, 618, 10.1016/j.arthro.2007.04.010
Isberg, 2006, Early active extension after anterior cruciate ligament reconstruction does not result in increased laxity of the knee, Knee Surg Sports Traumatol Arthrosc, 14, 1108, 10.1007/s00167-006-0138-2
Roberts, 2007, Clinical measurements of proprioception, muscle strength and laxity in relation to function in the ACL-injured knee, Knee Surg Sports Traumatol Arthrosc, 15, 9, 10.1007/s00167-006-0128-4
Scarvell, 2006, Does anterior cruciate ligament reconstruction restore normal knee kinematics?: a prospective MRI analysis over two years, J Bone Joint Surg [Br], 88, 324, 10.1302/0301-620X.88B3.16787
Laxdal, 2007, A prospective comparison of bone-patellar tendon-bone and hamstring tendon grafts for anterior cruciate ligament reconstruction in male patients, Knee Surg Sports Traumatol Arthrosc, 15, 115, 10.1007/s00167-006-0165-z
Draper, 1995, Examiner proficiency in performing the anterior drawer and Lachman tests, J Orthop Sports Phys Ther, 22, 263, 10.2519/jospt.1995.22.6.263
Jonsson, 1982, Clinical diagnosis of ruptures of the anterior cruciate ligament: a comparative study of the Lachman test and the anterior drawer sign, Am J Sports Med, 10, 100, 10.1177/036354658201000207
Kim, 1995, Reliability of the anterior drawer test, the pivot shift test, and the Lachman test, Clin Orthop, 237
Oberlander, 1993, The accuracy of the clinical knee examination documented by arthroscopy. A prospective study, Am J Sports Med, 21, 773, 10.1177/036354659302100603
Streiner, 2003
Aetna. Clinical Policy bulletins. www.aetna.com.
Ballantyne, 1995, Influence of examiner experience and gender on interrater reliability of KT-1000 arthrometer measurements, Phys Ther, 75, 898, 10.1093/ptj/75.10.898
Torzilli, 1991, Measurement reproducibility of two commercial knee test devices, J Orthop Res, 9, 730, 10.1002/jor.1100090513
Tyler, 1999, Association of KT-1000 measurements with clinical tests of knee stability 1 year following anterior cruciate ligament reconstruction, J Orthop Sports Phys Ther, 29, 540, 10.2519/jospt.1999.29.9.540
Katz, 1986, The diagnostic accuracy of ruptures of the anterior cruciate ligament comparing the Lachman test, the anterior drawer sign, and the pivot shift test in acute and chronic knee injuries, Am J Sports Med, 14, 88, 10.1177/036354658601400115
Hurley, 2003, Influences of clinician technique on performance and interpretation of the Lachman test, J Athl Train, 38, 34