The operation of the century: total hip replacement

The Lancet - Tập 370 - Trang 1508-1519 - 2007
Ian D Learmonth1, Claire Young2, Cecil Rorabeck3
1Department of Orthopaedics, Bristol Royal Infirmary, Bristol BS2 8HW, UK
2Cumberland Infirmary, Carlisle CA2 7HY, UK
3Department of Orthopaedics, University of Western Ontario, London Health Services Centre, London, Ontario, Canada

Tài liệu tham khảo

Buchanan, 1998, History of rheumatic diseases (ch 1), 1 Berato, 1990, [Epidemiology of rheumatic diseases in an ancient population: study of the Necropole du Haut-Empire de Saint-Lambert (Frejus, Var)], Rev Rhum Mal Osteoartic, 57, 397 Smith-Petersen, 1948, The classic: evolution of mould arthroplasty of the hip joint, J Bone Joint Surg, 30B, L59, 10.1302/0301-620X.30B1.59 Wiles, 1958, The surgery of the osteoarthritic hip, Br J Surg, 45, 488, 10.1002/bjs.18004519315 Charnley, 1961, Arthroplasty of the hip: a new operation, Lancet, 1, 1129, 10.1016/S0140-6736(61)92063-3 Berry, 2002, Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components, J Bone Joint Surg Am, 84A, 171, 10.2106/00004623-200202000-00002 Callaghan, 2000, Charnley total hip arthroplasty with cement: minimum twenty-five-year follow-up, J Bone Joint Surg Am, 82, 487, 10.2106/00004623-200004000-00004 Wroblewski, 1999, Charnley low-frictional torque arthroplasty of the hip: 20-to-30 year results, J Bone Joint Surg Br, 81, 427, 10.1302/0301-620X.81B3.9521 Kavanagh, 1994, Charnley low-friction arthroplasty of the hip: twenty-year results with cement, J Arthroplasty, 9, 229, 10.1016/0883-5403(94)90076-0 Older, 2002, Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years, J Arthroplasty, 17, 675, 10.1054/arth.2002.31973 Coventry, 1991, Foreword Fender, 1999, Outcome of Charnley total hip replacement across a single health region in England: the results at five years from a regional hip register, J Bone Joint Surg Br, 81, 577, 10.1302/0301-620X.81B4.9859 Charnley, 1975, Fracture of femoral prostheses in total hip replacement: a clinical study, Clin Orthop Relat Res, 111, 105, 10.1097/00003086-197509000-00014 Charnley, 1979, Long-term clinical results Eftekhar, 1987, Long-term results of cemented total hip arthroplasty, Clin Orthop Relat Res, 225, 207, 10.1097/00003086-198712000-00017 Wroblewski, 1985, Direction and rate of socket wear in Charnley low-friction arthroplasty, J Bone Joint Surg Br, 67, 757, 10.1302/0301-620X.67B5.4055876 Woo, 1982, Dislocations after total hip arthroplasty, J Bone Joint Surg Am, 64, 1295, 10.2106/00004623-198264090-00004 Dorr, 1990, Total hip arthroplasties in patients younger than 45 years: a nine- to ten-year follow-up study, Clin Orthop Relat Res, 260, 215, 10.1097/00003086-199011000-00036 Malchau H, Herberts P, Garellick G, Soderman P, Eisler T. Prognosis of total hip replacement: update of results and risk-ratio analysis for revision and re-revision from the Swedish National Hip Arthroplasty Register 1979–2000—Presented at the 69th Annual Meeting of the American Orthopaedic Surgeons; February 13–27, 2002; Dallas, TX, USA. Chandler, 1981, Total hip replacement in patients younger than thirty years old: a five-year follow-up study, J Bone Joint Surg Am, 63, 1426, 10.2106/00004623-198163090-00008 Glück, 1891, Referat über die durch das moderne chirurgische experiment gewonnenen positiven resultaten, betreffende die naht und den ersatz von defekten hőherer gewebe, sowie über die verwerthung resorbirbarer und lebendiger tampons in der chirurgie, Arch Klin Chir, 41, 187 Charnley, 1960, Anchorage of the femoral head prosthesis to the shaft of the femur, J Bone Joint Surg Br, 42B, 28, 10.1302/0301-620X.42B1.28 Askew, 1984, Effect of cement pressure and bone strength on polymethylmethacrylate fixation, J Orthop Res, 1, 412, 10.1002/jor.1100010410 Krause, 1982, Strength of the cement-bone interface, Clin Orthop Relat Res, 163, 290, 10.1097/00003086-198203000-00043 Majkowski, 1993, Bone surface preparation in cemented joint replacement, J Bone Joint Surg Br, 75, 459, 10.1302/0301-620X.75B3.8496223 Breusch, 2000, Lavage technique in total hip arthroplasty: jet lavage produces better cement penetration than syringe lavage in the proximal femur, J Arthroplasty, 15, 921, 10.1054/arth.2000.8098 Gozzard, 2003, An in-vitro investigation of the CPS-Plus femoral stem: influence of the proximal centraliser on cement pressurisation during stem insertion, Acta Orthop Scand, 74, 154, 10.1080/00016470310013879 Herberts, 2000, Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160 000 cases, Acta Orthop Scand, 71, 111, 10.1080/000164700317413067 Mulroy, 1990, The effect of improved cementing techniques on component loosening in total hip replacement: an 11-year radiographic review, J Bone Joint Surg Br, 72, 757, 10.1302/0301-620X.72B5.2211749 Williams, 2002, The Exeter universal cemented femoral component at 8 to 12 years: a study of the first 325 hips, J Bone Joint Surg Br, 84, 324, 10.1302/0301-620X.84B3.12261 Wroblewski, 2001, Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience, J Arthroplasty, 16, 37, 10.1054/arth.2001.28374 Langlais, 2003, The ‘French paradox’, J Bone Joint Surg Br, 85, 17, 10.1302/0301-620X.85B1.13948 Charnley, 1972, The long-term results of low-friction arthroplasty of the hip performed as a primary intervention, J Bone Joint Surg Br, 54, 61, 10.1302/0301-620X.54B1.61 Dall, 1993, Fracture and loosening of Charnley femoral stems: comparison between first-generation and subsequent designs, J Bone Joint Surg Br, 75, 259, 10.1302/0301-620X.75B2.8444947 Malchau H, Herberts P. Prognosis of total hip replacement: surgical and cementing technique in THR—a revision-risk study of 134 056 primary operations. 63rd Annual Meeting of the American Academy of Orthopaedic Surgeons; 22–25 February, 1996; Atlanta, GA, USA. Massoud, 1997, Early femoral loosening in one design of cemented hip replacement, J Bone Joint Surg Br, 79, 603, 10.1302/0301-620X.79B4.7131 Havelin, 2002, The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups: from the Norwegian Arthroplasty Register, J Bone Joint Surg Br, 84, 839, 10.1302/0301-620X.84B6.12492 Gie GA, Hoe F, Timperley AJ, Ling RSM. The Exeter polished stem in the longer term: a survivorship study to the 33rd year of follow-up and a study of stem subsistence. European Hip Society; 23–26 June, 2004; Innsbruck, Austria. Spitzer, 2005, The cemented femoral stem: selecting the ideal patient, Orthopedics, 28, S841, 10.3928/0147-7447-20050802-08 Charnley, 1979, Long-term radiological results Harris, 1976, Extensive localized bone resorption in the femur following total hip replacement, J Bone Joint Surg Am, 58, 612, 10.2106/00004623-197658050-00005 Maloney, 1990, Bone lysis in well-fixed cemented femoral components, J Bone Joint Surg Br, 72, 966, 10.1302/0301-620X.72B6.2246299 Jasty, 1986, Localized osteolysis in stable, non-septic total hip replacement, J Bone Joint Surg Am, 68, 912, 10.2106/00004623-198668060-00014 Jones, 1987, Cement disease, Clin Orthop Relat Res, 225, 192, 10.1097/00003086-198712000-00016 Lavernia, 2004, Thigh pain in primary total hip arthroplasty: the effects of elastic moduli, J Arthroplasty, 19, 10, 10.1016/j.arth.2004.06.023 Bourne, 1994, Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis: a five-year follow-up study, J Bone Joint Surg Am, 76, 1464, 10.2106/00004623-199410000-00005 Keaveny, 1995, Mechanical consequences of bone ingrowth in a hip prosthesis inserted without cement, J Bone Joint Surg Am, 77, 911, 10.2106/00004623-199506000-00012 Schmalzried, 1992, Periprosthetic bone loss in total hip arthroplasty: polyethylene wear debris and the concept of the effective joint space, J Bone Joint Surg Am, 74, 849, 10.2106/00004623-199274060-00006 McAuley, 1998, Total hip arthroplasty: concerns with extensively porous coated femoral components, Clin Orthop Relat Res, 355, 182, 10.1097/00003086-199810000-00019 Campbell, 1992, Thigh pain after cementless hip arthroplasty: annoyance or ill omen, J Bone Joint Surg Br, 74, 63, 10.1302/0301-620X.74B1.1732268 Bourne, 2001, Tapered titanium cementless total hip replacements: a 10- to 13-year followup study, Clin Orthop Relat Res, 393, 112, 10.1097/00003086-200112000-00013 Reitman, 2003, Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone, J Arthroplasty, 18, 116, 10.1016/S0883-5403(03)00344-9 Parvizi, 2004, Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem, J Arthroplasty, 19, 151, 10.1016/j.arth.2003.10.003 Barrack, 1992, Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty: a 12-year radiographic review, J Bone Joint Surg Br, 74, 385, 10.1302/0301-620X.74B3.1587883 Capello, 1993, Failure of the Mecron screw-in ring, J Bone Joint Surg Br, 75, 835, 10.1302/0301-620X.75B5.8376454 Fox, 1994, Hip replacement with a threaded acetabular cup: a follow-up study, J Bone Joint Surg Am, 76, 195, 10.2106/00004623-199402000-00005 Udomkiat, 2002, Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up, J Bone Joint Surg Am, 84A, 1195, 10.2106/00004623-200207000-00015 Clohisy, 1999, The Harris-Galante porous-coated acetabular component with screw fixation: an average ten-year follow-up study, J Bone Joint Surg Am, 81, 66, 10.2106/00004623-199901000-00010 Ries, 1992, Separation of the polyethylene liner from acetabular cup metal backing: a report of three cases, Clin Orthop Relat Res, 282, 164, 10.1097/00003086-199209000-00021 Barrack, 1993, Complications related to modularity of total hip components, J Bone Joint Surg Br, 75, 688, 10.1302/0301-620X.75B5.8376421 della Valle, 2001, Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components: a report of eighteen cases, J Bone Joint Surg Am, 83A, 553, 10.2106/00004623-200104000-00010 Louwerse, 1999, Late failure of the polyethylene liner fixation in an uncemented total hip arthroplasty, J Arthroplasty, 14, 391, 10.1016/S0883-5403(99)90070-0 Duffy, 2004, Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty, J Bone Joint Surg Br, 86, 34, 10.1302/0301-620X.86B1.13402 Cook, 1988, Quantitative analysis of tissue growth into human porous total hip components, J Arthroplasty, 3, 249, 10.1016/S0883-5403(88)80023-8 Freeman, 1998, Hydroxyapatite: catalyst or conjurer?, Orthopedics, 21, 959, 10.3928/0147-7447-19980901-09 Rasquinha, 2002, Hydroxyapatite: catalyst or conjuror?, J Arthroplasty, 17, 113, 10.1054/arth.2002.32810 D'Antonio, 2001, Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13-year followup, Clin Orthop Relat Res, 393, 101, 10.1097/00003086-200112000-00012 Herberts, 2005 Kim, 2005, Long-term results of the cementless porous-coated anatomic total hip prosthesis, J Bone Joint Surg Br, 87, 623, 10.1302/0301-620X.87B5.15554 Capello, 2003, Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old: a concise follow-up of a previous report, J Bone Joint Surg Am, 85A, 885, 10.2106/00004623-200305000-00017 Kearns, 2006, Factors affecting survival of uncemented total hip arthroplasty in patients 50 years or younger, Clin Orthop Relat Res, 453, 103, 10.1097/01.blo.0000238868.22852.dd Bragdon, 2003, The efficacy of BMP-2 to induce bone ingrowth in a total hip replacement model, Clin Orthop Relat Res, 417, 50, 10.1097/01.blo.0000096811.78689.2b Bragdon, 2004, Biologic fixation of total hip implants: insights gained from a series of canine studies, J Bone Joint Surg Am, 86A, 105, 10.2106/00004623-200412002-00015 Jasty, 1992, Porous-coated uncemented components in experimental total hip arthroplasty in dogs: effect of plasma-sprayed calcium phosphate coatings on bone ingrowth, Clin Orthop Relat Res, 280, 300, 10.1097/00003086-199207000-00041 Maloney, 1990, Endosteal erosion in association with stable uncemented femoral components, J Bone Joint Surg Am, 72, 1025, 10.2106/00004623-199072070-00011 Vernon-Roberts, 1977, The tissue response to total joint replacement prostheses, 86 Willert, 1977, Reactions of the articular capsule to wear products of artificial joint prostheses, J Biomed Mater Res, 11, 157, 10.1002/jbm.820110202 Archibeck, 2001, The basic science of periprosthetic osteolysis, Instr Course Lect, 50, 185 Amstutz, 1992, Mechanism and clinical significance of wear debris-induced osteolysis, Clin Orthop Relat Res, 276, 7, 10.1097/00003086-199203000-00003 Green, 1998, Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro, Biomaterials, 19, 2297, 10.1016/S0142-9612(98)00140-9 Ries, 2001, Relationship between gravimetric wear and particle generation in hip simulators: conventional compared with cross-linked polyethylene, J Bone Joint Surg Am, 83A, 116, 10.2106/00004623-200100022-00009 Saikko, 2002, Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator, J Biomed Mater Res, 63, 848, 10.1002/jbm.10471 D'Antonio, 2005, Five-year experience with Crossfire highly cross-linked polyethylene, Clin Orthop Relat Res, 441, 143, 10.1097/00003086-200512000-00024 McKee, 1966, Replacement of arthritic hips by the McKee-Farrar prosthesis, J Bone Joint Surg Br, 48, 245, 10.1302/0301-620X.48B2.245 Ring, 1968, Complete replacement arthroplasty of the hip by the ring prosthesis, J Bone Joint Surg Br, 50, 720, 10.1302/0301-620X.50B4.720 Muller, 1970, Total hip prostheses, Clin Orthop Relat Res, 72, 46 Jacobsson, 1996, Twenty-year results of McKee-Farrar versus Charnley prosthesis, Clin Orthop Relat Res, 329, S60, 10.1097/00003086-199608001-00006 Schmalzried, 1996, Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces, J Arthroplasty, 11, 322, 10.1016/S0883-5403(96)80085-4 McKellop, 1996, In vivo wear of three types of metal on metal hip prostheses during two decades of use, Clin Orthop Relat Res, 329, S128, 10.1097/00003086-199608001-00013 Naudie, 2004, Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study, J Arthroplasty, 19, 35, 10.1016/j.arth.2004.06.020 Brodner, 1997, Elevated serum cobalt with metal-on-metal articulating surfaces, J Bone Joint Surg Br, 79, 316, 10.1302/0301-620X.79B2.7326 Macdonald, 2003, Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial, Clin Orthop Relat Res, 406, 282, 10.1097/00003086-200301000-00039 Clarke, 2003, Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty, J Bone Joint Surg Br, 85, 913, 10.1302/0301-620X.85B6.14166 Harding, 2002, Serum levels of cobalt and chromium in a complex modular total hip arthroplasty system, J Arthroplasty, 17, 893, 10.1054/arth.2002.34539 Semlitsch, 1997, Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements, Proc Inst Mech Eng [H], 211, 73, 10.1243/0954411971534700 Lerouge, 1997, Ceramic-ceramic and metal-polyethylene total hip replacements: comparison of pseudomembranes after loosening, J Bone Joint Surg Br, 79, 135, 10.1302/0301-620X.79B1.6621 Fritsch, 1996, Ceramic femoral head fractures in total hip arthroplasty, Clin Orthop Relat Res, 328, 129, 10.1097/00003086-199607000-00021 Callaway, 1995, Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty, J Arthroplasty, 10, 855, 10.1016/S0883-5403(05)80087-7 D'Antonio, 2005, Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study, Clin Orthop Relat Res, 436, 164, 10.1097/01.blo.0000162995.50971.39 Bourne, 2005, Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene, Clin Orthop Relat Res, 441, 159, 10.1097/01.blo.0000193813.08458.e2 Good, 2003, Reduced wear with oxidized zirconium femoral heads, J Bone Joint Surg Am, 85A, 105, 10.2106/00004623-200300004-00013 Jolley, 1982, Early results and complications of surface replacement of the hip, J Bone Joint Surg Am, 64, 366, 10.2106/00004623-198264030-00006 Bell, 1985, A study of implant failure in the Wagner resurfacing arthroplasty, J Bone Joint Surg Am, 67, 1165, 10.2106/00004623-198567080-00004 Head, 1981, Wagner surface replacement arthroplasty of the hip: analysis of fourteen failures in forty-one hips, J Bone Joint Surg Am, 63, 420, 10.2106/00004623-198163030-00017 Freeman, 1978, Cemented double cup arthroplasty of the hip: a 5 year experience with the ICLH prosthesis, Clin Orthop Relat Res, 134, 45 McMinn, 1996, Metal on metal surface replacement of the hip: experience of the McMinn prothesis, Clin Orthop Relat Res, 329, S89, 10.1097/00003086-199608001-00009 Treacy, 2005, Birmingham hip resurfacing arthroplasty: a minimum follow-up of five years, J Bone Joint Surg Br, 87, 167, 10.1302/0301-620X.87B2.15030 Shimmin, 2005, Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases, J Bone Joint Surg Br, 87, 463, 10.1302/0301-620X.87B4.15498 Amstutz, 2004, Fracture of the neck of the femur after surface arthroplasty of the hip, J Bone Joint Surg Am, 86A, 1874, 10.2106/00004623-200409000-00003 Beaulé, 2004, Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip, Clin Orthop Relat Res, 418, 87, 10.1097/00003086-200401000-00015 Eastaugh-Waring, 2006, The practical limitations of resurfacing hip arthroplasty, J Arthroplasty, 21, 18, 10.1016/j.arth.2005.04.016 Malchau, 2002, The Swedish Total Hip Replacement Register, J Bone Joint Surg Am, 84A, 2, 10.2106/00004623-200200002-00002 Dorr, 1994, Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: a 16-year follow-up study, J Arthroplasty, 9, 453, 10.1016/0883-5403(94)90090-6 Engh, 1987, Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results, J Bone Joint Surg Br, 69, 45, 10.1302/0301-620X.69B1.3818732 Tennent, 2000, Current attitudes to total hip replacement in the younger patient: results of a national survey, Ann R Coll Surg Engl, 82, 33 Huggler, 1993, Long-term results with the uncemented thrust plate prosthesis (TPP), Acta Orthop Belg, 59, 215 Buergi, 2005, Radiological findings and clinical results of 102 thrust-plate femoral hip prostheses: a follow-up of 2 to 8 years, J Arthroplasty, 20, 108, 10.1016/j.arth.2004.09.042 Morrey, 2000, A conservative femoral replacement for total hip arthroplasty: a prospective study, J Bone Joint Surg Br, 82, 952, 10.1302/0301-620X.82B7.10420 Berry, 2003, Minimally invasive total hip arthroplasty: development, early results, and a critical analysis—presented at the Annual Meeting of the American Orthopaedic Association, Charleston, South Carolina, USA, June 14, 2003, J Bone Joint Surg Am, 85A, 2235, 10.2106/00004623-200311000-00029 2006 Ogonda, 2005, A minimal-incision technique in total hip arthroplasty does not improve early postoperative outcomes: a prospective, randomized, controlled trial, J Bone Joint Surg Am, 87, 701, 10.2106/JBJS.D.02645 Chimento, 2005, Minimally invasive total hip arthroplasty: a prospective randomized study, J Arthroplasty, 20, 139, 10.1016/j.arth.2004.09.061 Berger, 2004, The two-incision minimally invasive total hip arthroplasty: technique and results, Orthop Clin North Am, 35, 163, 10.1016/S0030-5898(03)00110-X Bal, 2005, Early complications of primary total hip replacement performed with a two-incision minimally invasive technique, J Bone Joint Surg Am, 87, 2432, 10.2106/JBJS.D.02847 2005 Stiehl, 2003 DiGioia, 2002, Comparison of a mechanical acetabular alignment guide with computer placement of the socket, J Arthroplasty, 17, 359, 10.1054/arth.2002.30411 Nogler, 2004, Navigated minimal invasive total hip arthroplasty, Surg Technol Int, 12, 259 Charnley, 1972, The long-term results of low-friction arthroplasty of the hip performed as a primary intervention, J Bone Joint Surg Br, 54B, 61, 10.1302/0301-620X.54B1.61 Harris, 1969, Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty—an end-result study using a new method of result evaluation, J Bone Joint Surg Am, 51, 737, 10.2106/00004623-196951040-00012 Dobbs, 1980, Survivorship of total hip replacements, J Bone Joint Surg Br, 62B, 168, 10.1302/0301-620X.62B2.7364829 Kaplan, 1958, Nonparametric estimation from incomplete observations, J Am Stat Assoc, 53, 457, 10.1080/01621459.1958.10501452 Janse, 2004, Quality of life: patients and doctors don't always agree: a meta-analysis, J Clin Epidemiol, 57, 653, 10.1016/j.jclinepi.2003.11.013 Ware Bellamy, 1988, Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee, J Rheumatol, 15, 1833 Dawson, 1996, Questionnaire on the perceptions of patients about total hip replacement, J Bone Joint Surg Br, 78, 185, 10.1302/0301-620X.78B2.0780185 Hewlett, 2002, Measuring the meaning of disability in rheumatoid arthritis: the personal impact health assessment questionnaire (PI HAQ), Ann Rheum Dis, 61, 986, 10.1136/ard.61.11.986 Wylde, 2006, Personal impact of disability in osteoarthritis: patient, professional and public values, Musculoskeletal Care, 4, 152, 10.1002/msc.86 Wright, 1994, Ask patients what they want: evaluation of individual complaints before total hip replacement, J Bone Joint Surg Br, 76, 229, 10.1302/0301-620X.76B2.8113282 Harris, 2004, Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis, Clin Orthop Relat Res, 429, 39, 10.1097/01.blo.0000149821.72760.39 Lappalainen, 2005, Potential of coatings in total hip replacement, Clin Orthop Relat Res, 430, 72, 10.1097/01.blo.0000150000.75660.ff Fehring, 2005, Catastrophic complications of minimally invasive hip surgery: a series of three cases, J Bone Joint Surg Am, 87, 711, 10.2106/JBJS.D.02666 Berry, 2005, Minimally invasive total hip arthroplasty, J Bone Joint Surg Am, 87, 699, 10.2106/JBJS.E.00126 DiGioia, 1998, Computer assisted orthopaedic surgery: image guided and robotic assistive technologies, Clin Orthop Relat Res, 354, 8, 10.1097/00003086-199809000-00003