25-Hydroxyvitamin D Measurement, 2009: A Review for Clinicians
Tài liệu tham khảo
Holick, 1995, Environmental factors that influence the cutaneous production of vitamin D, Am J Clin Nutr, 61, 638S, 10.1093/ajcn/61.3.638S
Holick, 1985, The photobiology of vitamin D and its consequences for humans, Ann N Y Acad Sci, 453, 1, 10.1111/j.1749-6632.1985.tb11793.x
Looker, 2002, Serum 25-hydroxyvitamin D status of adolescents and adults in two seasonal subpopulations from NHANES III, Bone, 30, 771, 10.1016/S8756-3282(02)00692-0
Rucker, 2002, Vitamin D insufficiency in a population of healthy western Canadians, Can Med Assoc J, 166, 1517
Nesby-O'Dell, 2002, Hypovitaminosis D prevalence and determinants among African American and white women of reproductive age: third National Health and Nutrition Examination Survey, 1988-1994, Am J Clin Nutr, 76, 187, 10.1093/ajcn/76.1.187
Calvo, 2003, Prevalence of vitamin D insufficiency in Canada and the United States: importance to health status and efficacy of current food fortification and dietary supplement use, Nutr Rev, 61, 107, 10.1301/nr.2003.marr.107-113
Holick, 2007, Vitamin D deficiency, N Engl J Med, 357, 266, 10.1056/NEJMra070553
Binkley, 2007, Does low vitamin D status contribute to “age-related” morbidity?, J Bone Miner Res, 22, V55, 10.1359/jbmr.07s212
DeLuca, 1988, The vitamin D story: a collaborative effort of basic science and clinical medicine, FASEB J, 2, 224, 10.1096/fasebj.2.3.3280376
Standing Committee on the Scientific Evaluation of Dietary Reference Intakes Food and Nutrition Board, Institute of Medicine, 1997
Hollis, 2007, The assessment of circulating 25(OH)D and 1, 25 (OH)2D: where we are and where we are going, J Steroid Biochem Mol Biol, 103, 473, 10.1016/j.jsbmb.2006.11.004
Armas, 2004, Vitamin D2 is much less effective than vitamin D3 in humans, J Clin Endocrinol Metab, 89, 5387, 10.1210/jc.2004-0360
Houghton, 2006, The case against ergocalciferol (vitamin D2) as a vitamin supplement, Am J Clin Nutr, 84, 694, 10.1093/ajcn/84.4.694
Holick, 2008, Vitamin D2 is as effective as vitamin D3 in maintaining circulating concentrations of 25-hydroxyvitamin D, J Clin Endocrinol Metab, 93, 677, 10.1210/jc.2007-2308
Glendenning, 2008, Ergocalciferol is not bioequivalent to cholecalciferol in vitamin D insufficient hip fracture cases, J Bone Miner Res, 23, S81
Anonymous Vitamin D deficiency: informationfor cancer patients. 2008 (Accessed: October 24, 2008, Available at: www.boneandcancerfoundation.org).
Holick, 2002, Too little vitamin D in premenopausal women: why should we care?, Am J Clin Nutr, 76, 3, 10.1093/ajcn/76.1.3
Giovannucci, 2007, Can vitamin D reduce total mortality?, Arch Intern Med, 167, 1709, 10.1001/archinte.167.16.1709
Anonymous. 2007 Annual report of the boards of trustees of the federal hospital insurance and federal supplementary medical insurance trust funds. (Accessed: October 23, 2008, Available at: www.cms.hhs.gov/reportstrustfunds/downloads/tr2007.pdf).
Heaney, 2006, Barriers to optimizing vitamin D3 intake for the elderly, J Nutr, 136, 1123, 10.1093/jn/136.4.1123
Binkley, 2008, Effect of vitamin D2 or vitamin D3 supplementation on serum 25OHD, J Bone Miner Res, 23, S350
MacLaughlin, 1985, Aging decreases the capacity of human skin to produce vitamin D3, J Clin Invest, 76, 1536, 10.1172/JCI112134
Weaver, 2004, Vitamin D requirements: current and future, Am J Clin Nutr, 80, 1735S, 10.1093/ajcn/80.6.1735S
Matsuoka, 1991, Racial pigmentation and the cutaneous synthesis of vitamin D, Arch Dermatol, 127, 536, 10.1001/archderm.127.4.536
Haddad, 1971, Competitive protein-binding radioassay for 25-hydroxycholecalciferol, J Clin Endocrinol Metab, 33, 992, 10.1210/jcem-33-6-992
Belsey, 1971, Competitive binding assay for vitamin D and 25-OH vitamin D, J Clin Endocrinol Metab, 33, 554, 10.1210/jcem-33-3-554
Hollis, 1985, Improved radioimmunoassay for vitamin D and its use in assessing vitamin D status, Clin Chem, 31, 1815, 10.1093/clinchem/31.11.1815
2005
Leino, 2008, Automated measurement of 25-OH vitamin D3 on the Roche modular E170 analyzer, Clin Chem, 54, 1, 10.1373/clinchem.2008.111732
Caldwell, 1987, Gas chromatography-mass spectrometry and the measurement of vitamin D metabolites in human serum or plasma, Steroids, 49, 155, 10.1016/0039-128X(87)90083-3
Seamark, 1980, The estimation of vitamin D and some metabolites in human plasma by mass fragmentography, Clin Chim Acta, 106, 51, 10.1016/0009-8981(80)90374-5
Eisman, 1977, Determination of 25-hydroxyvitamin D2 and of 25-hydroxyvitamin D3 in plasma using high-pressure liquid chromatography, Anal Biochem, 90, 298, 10.1016/0003-2697(77)90648-0
Turpeinen, 2003, Determination of 25-hydroxyvitamin D in serum by HPLC and immunoassay, Clin Chem, 49, 1521, 10.1373/49.9.1521
Lensmeyer, 2006, Measurement of 25-hydroxyvitamin D revisited: reply to letter, Clin Chem, 52, 2305, 10.1373/clinchem.2006.079459
Maunsell, 2005, Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for the simultaneous measurement of the 25-hydroxymetabolites of vitamins D2 and D3, Clin Chem, 51, 1683, 10.1373/clinchem.2005.052936
Vogeser, 2004, Candidate reference method for the quantitation of circulating 25-hydroxyvitamin D3 by liquid chromatography tandem-mass spectrometry, Clin Chem, 50, 1415, 10.1373/clinchem.2004.031831
Chen, 2008, Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method, Clin Chim Acta, 391, 6, 10.1016/j.cca.2008.01.017
Singh, 2006, C-3 epimers can account for a significant portion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status, J Clin Endocrinol Metab, 91, 3055, 10.1210/jc.2006-0710
Lensmeyer, 2006, HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays, Clin Chem, 52, 1120, 10.1373/clinchem.2005.064956
Trang, 1998, Evidence that vitamin D3 increases serum 25-hydroxyvitamin D more efficiently than does vitamin D2, Am J Clin Nutr, 68, 854, 10.1093/ajcn/68.4.854
Stenman, 2001, Immunoassay standardization: is it possible, who is responsible, who is capable?, Clin Chem, 47, 815, 10.1093/clinchem/47.5.815
Valdes, 2002, Unexpected suppression of immunoassay results by cross-reactivity: now a demonstrated cause for concern, Clin Chem, 48, 405, 10.1093/clinchem/48.3.405
Roth, 2008, Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference, Ann Clin Biochem, 45, 153, 10.1258/acb.2007.007091
Glendenning, 2006, Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite-specific assays, Ann Clin Biochem, 43, 23, 10.1258/000456306775141650
Hollis, 2008, Assessment of vitamin D status and definition of a normal circulating range of 25-hydroxyvitamin D, Curr Opin Endocrinol Diab Obes, 15, 489, 10.1097/MED.0b013e328317ca6c
Ramakkrishnan, 2005, Underestimation of 25-OHvitamin D by Nichols Advantage Assay in patients receiving vitamin D replacement therapy, Clin Chem, 51, 1074, 10.1373/clinchem.2005.051508
Cavalier, 2008, Serum vitamin D measurement may not reflect what you give to your patients, J Bone Miner Res, 23, 1864, 10.1359/jbmr.080608
Lensmeyer, 2006, New horizons for assessment of vitamin D status in man, 513, 10.1016/B9-78-012088-5/62650-0327
Healy, 1979, Outliers in clinical chemistry quality-control schemes, Clin Chem, 25, 675, 10.1093/clinchem/25.5.675
Binkley, 2006, Vitamin D: clinical measurement and use, J Musculoskelet Neuronal Interact, 6, 338
Binkley, 2007, Low vitamin D status despite abundant sun exposure, J Clin Endocrinol Metab, 92, 2130, 10.1210/jc.2006-2250
Phinney, 2008, Development of a standard reference material for vitamin D in serum, Am J Clin Nutr, 88, 511S, 10.1093/ajcn/88.2.511S
Binkley, 2008, What is your patient's vitamin D status? Clinical consideration of variability in a 25(OH)D measurement, J Bone Miner Res, 23, S351
Rejnmark, 2006, Vitamin D and its binding protein Gc: long-term variability in peri- and postmenopausal women with and without hormone replacement therapy, Scand J Clin Lab Invest, 66, 227, 10.1080/00365510600570623
Lester, 1977, Seasonal variation in serum 25-hydroxyvitamin D in the elderly in Britain, Lancet, 1, 979, 10.1016/S0140-6736(77)92280-2
Dawson-Hughes, 2005, Estimates of optimal vitamin D status, Osteoporos Int, 16, 713, 10.1007/s00198-005-1867-7
Lips, 2001, Vitamin D deficiency and secondary hyperparathyroidism in the elderly: consequences for bone loss and fractures and therapeutic implications, Endocr Rev, 22, 477, 10.1210/er.22.4.477
Vieth, 2007, Vitamin D toxicity, policy and science, J Bone Miner Res, 22, V64, 10.1359/jbmr.07s221
Vieth, 1999, Vitamin D supplementation, 25-hydroxyvitamin D concentrations and safety, Am J Clin Nutr, 69, 842, 10.1093/ajcn/69.5.842
Hollis, 2005, Circulating 25-hydroxyvitamin D levels indicative of vitamin D sufficiency: implications for establishing a new effective dietary intake recommendation for vitamin D, J Nutr, 135, 317, 10.1093/jn/135.2.317
Barger-Lux, 2002, Effects of above average summer sun exposure on serum 25-hydroxyvitamin D and calcium absorption, J Clin Endocrinol Metab, 87, 4952, 10.1210/jc.2002-020636
Binkley, 2006, Laboratory reporting of 25-hydroxyvitamin D results: potential for clinical misinterpretation, Clin Chem, 52, 2124, 10.1373/clinchem.2006.074922
Bischoff-Ferrari, 2006, Estimation of optimal serum concentrations of 25-hydroxyvitamin D for multiple health outcomes, Am J Clin Nutr, 84, 18, 10.1093/ajcn/84.1.18
Binkley, 2009, Is clinical measurement of 25-hydroxyvitamin D still a problem?, Osteoporos Int, 20, S202
Tangpricha, 2004, Tanning is associated with optimal vitamin D status (serum 25-hydroxyvitamin D concentration) and higher bone mineral density, Am J Clin Nutr, 80, 1645, 10.1093/ajcn/80.6.1645
Heaney, 2006, Nutrition and chronic disease, Mayo Clin Proc, 81, 297, 10.4065/81.3.297
Lowe, 2008, Vitamin D toxicity due to a commonly available remedy from the Dominican Republic, J Bone Miner Res, 23, S288
Pepper, 2009, Evaluation of vitamin D repletion regimens to correct vitamin D status in adults, Endocr Pract, 15, 95, 10.4158/EP.15.2.95
Przybelski, 2008, Rapid correction of low vitamin D status in nursing home residents, Osteoporos Int, 19, 1621, 10.1007/s00198-008-0619-x
Malabanan, 1998, Redefining vitamin D insufficiency, Lancet, 351, 805, 10.1016/S0140-6736(05)78933-9
Heaney, 2003, Human serum 25-hydroxycholecalciferol response to extended oral dosing with cholecalciferol, Am J Clin Nutr, 77, 204, 10.1093/ajcn/77.1.204
Hollis, 2008, Measuring 25-hydroxyvitamin D in a clinical environment: challenges and needs, Am J Clin Nutr, 88, 507S, 10.1093/ajcn/88.2.507S