Keratometry in children: Comparison between auto-refractokeratometer, rotating scheimpflug imaging, and biograph
Tài liệu tham khảo
Eibschitz-Tsimhoni, 2007, Intraocular lens power calculation in children, Surv Ophthalmol, 52, 474, 10.1016/j.survophthal.2007.06.010
Fledelius, 1988, Oculometric considerations with reference to age and refractive change, Acta Ophthalmol Suppl, 185, 74
Friedman, 1996, Corneal changes in schoolchildren, Optom Vis Sci, 73, 552, 10.1097/00006324-199608000-00006
Yasuda, 2003, Changes in corneal curvature in accommodation, J Cataract Refract Surg, 29, 1297, 10.1016/S0886-3350(03)00118-4
Sjostrand, 1990, Risk factors in amblyopia, Eye (Lond), 4, 787, 10.1038/eye.1990.124
Buehren, 2003, Corneal topography and accommodation, Cornea, 22, 311, 10.1097/00003226-200305000-00007
He, 2003, Change in corneal shape and corneal wave-front aberrations with accommodation, J Vis, 3, 456, 10.1167/3.7.1
Read, 2007, Influence of accommodation on the anterior and posterior cornea, J Cataract Refract Surg, 33, 1877, 10.1016/j.jcrs.2007.06.048
Yasuda, 2005, Steepening of corneal curvature with contraction of the ciliary muscle, J Cataract Refract Surg, 31, 1177, 10.1016/j.jcrs.2004.10.058
Carkeet, 2004, Repeatability of IOLMaster biometry in children, Optom Vis Sci, 81, 829, 10.1097/01.OPX.0000145020.33250.C0
Huynh, 2006, An evaluation of keratometry in 6-year-old children, Cornea, 25, 383, 10.1097/01.ico.0000214203.84081.ec
Liang, 2004, Comparison of the handheld Retinomax K-Plus2 and on-table autokeratometers in children with and without cycloplegia, J Cataract Refract Surg, 30, 669, 10.1016/S0886-3350(03)00662-X
Emamian, 2018, Cohort profile: Shahroud Schoolchildren Eye Cohort Study (SSCECS), Int J Epidemiol
Thibos, 1997, Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error, Optom Vis Sci, 74, 367, 10.1097/00006324-199706000-00019
Chen, 2012, Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: repeatability and agreement, J Cataract Refract Surg, 38, 1626, 10.1016/j.jcrs.2012.04.031
Dehnavi, 2015, Comparison of the corneal power measurements with the TMS4-topographer, pentacam HR IOL master, and javal keratometer, Middle East Afr J Ophthalmol, 22, 233, 10.4103/0974-9233.151884
Elbaz, 2007, Comparison of different techniques of anterior chamber depth and keratometric measurements, Am J Ophthalmol, 143, 48, 10.1016/j.ajo.2006.08.031
Hashemi, 2014, Agreement study of keratometric values measured by Biograph/LENSTAR, auto-kerato-refractometer and Pentacam: decision for IOL calculation, Clin Exp Optom, 97, 450, 10.1111/cxo.12186
H. Hashemi, 2014, Comparison of keratometric values using javal keratometer, Oculus Pentacam, and Orbscan II, Iran J Ophthalmol, 26, 3
Huang, 2011, Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry, J Cataract Refract Surg, 37, 341, 10.1016/j.jcrs.2010.08.044
Modis, 2012, Keratometry evaluations with the Pentacam high resolution in comparison with the automated keratometry and conventional corneal topography, Cornea, 31, 36, 10.1097/ICO.0b013e318204c666
Ucakhan, 2013, Comparison of corneal curvature and anterior chamber depth measurements using the manual keratometer Lenstar LS 900 and the Pentacam, Middle East Afr J Ophthalmol, 20, 201, 10.4103/0974-9233.114791
Zhao, 2013, Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes, Clin Exp Optom, 96, 92, 10.1111/j.1444-0938.2012.00793.x
Ventura, 2015, Repeatability and comparability of corneal power and corneal astigmatism obtained from a point-source color light-emitting diode topographer, a Placido-based corneal topographer, and a low-coherence reflectometer, J Cataract Refract Surg, 41, 2242, 10.1016/j.jcrs.2015.11.003
Ferreira, 2018, Comparability and repeatability of different methods of corneal astigmatism assessment, Clin Ophthalmol, 12, 29, 10.2147/OPTH.S146730
Kobashi, 2012, Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer, J Cataract Refract Surg, 38, 648, 10.1016/j.jcrs.2011.11.026
Jasvinder, 2011, Agreement analysis of LENSTAR with other techniques of biometry, Eye (Lond), 25, 717, 10.1038/eye.2011.28
Eskridge, 1991
Cruysberg, 2010, Evaluation of the Lenstar LS 900 non-contact biometer, Br J Ophthalmol, 94, 106, 10.1136/bjo.2009.161729
Belin, 2009, An introduction to understanding elevation-based topography: how elevation data are displayed – a review, Clin Exp Ophthalmol, 37, 14, 10.1111/j.1442-9071.2008.01821.x
Kiely, 1984, Meridional variations of corneal shape, Am J Optom Physiol Opt, 61, 619, 10.1097/00006324-198410000-00001
Buckhurst, 2009, A new optical low coherence reflectometry device for ocular biometry in cataract patients, Br J Ophthalmol, 93, 949, 10.1136/bjo.2008.156554
Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, 307, 10.1016/S0140-6736(86)90837-8
Pierscionek, 2001, Corneal shape change during accommodation, Eye (Lond), 15, 766, 10.1038/eye.2001.246